NextSDS Logo
hy

hydrolyzed

NO SIGNAL WORD solid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
hydrolyzed
Product Code
41238
Chemical Name
Polyvinyl alcohol, hydrolyzed

Regulatory Identifiers

CAS Number

Chemical Abstracts Service registry number - unique identifier for chemical substances

EC Number

European Community number - used for regulatory compliance in EU/EEA

Uses Information

Identified Uses
SU24 Scientific research and development
Uses Advised Against
No further relevant information available.

Overview

hydrolyzed (CAS: 9002-89-5 ) commonly used su24 scientific research and development.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Alfa Aesar Thermo Fisher Scientific Chemicals, Inc. company logo - Safety Data Sheet supplier organization

Alfa Aesar Thermo Fisher Scientific Chemicals, Inc.

manufacturer

πŸ“

30 Bond Street, Ward Hill, MA 01835-8099

🌍

US

πŸ“ž

800-343-0660

πŸ“ 

800-322-4757

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Alfa Aesar

πŸ“ž

(800) 343-0660

🌍

US

πŸ•’

Monday-Friday, 8am-7pm EST

Carechem 24

πŸ“ž

(866) 928-0789

🌍

US

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

General Composition

Substances

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Polyvinyl alcohol, hydrolyzed
EC: 618-340-9
9002-89-5 100% βœ“ Non-hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Supply fresh air. If required, provide artificial respiration. Keep patient warm.

πŸ–οΈ Skin Contact

Immediately wash with water and soap and rinse thoroughly.

πŸ‘οΈ Eye Contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

🍽️ Ingestion/Swallowing

Seek medical treatment.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

πŸ§ͺ Physical State
solid
Critical Property
πŸ“Š Physical State Data
solid
πŸ“Š State Under Standard Conditions
Not available
πŸ‘οΈ Appearance
Not available
🎨 Colour
Not available
πŸ“Š Colour Intensity
Not available
πŸ“Š Form
Powder
πŸ‘ƒ Odor
Odorless
πŸ“Š Odor Threshold
Not determined.
πŸ§ͺ Ph
Not applicable.
🧊 Melting Point
200 Β°C (392 ΒΊF)
Critical Property
πŸ’¨ Boiling Point
Not determined
Critical Property
πŸ”₯ Flash Point
79 Β°C (174 Β°F)
Critical Property
πŸ“Š Freezing Point
Not available
πŸ“Š Softening Point
Not available
πŸ“Š Solidification Point
Not available
πŸ“Š Cloud Point
Not available
πŸ“Š Crystallisation Point
Not available
πŸ“Š Relative Evaporation Rate
Not available
πŸ’¨ Evaporation Rate
Not applicable.
πŸ’¨ Vapor Pressure
Not applicable.
πŸ“Š Vapor Density
Not applicable.
πŸ“Š Relative Density
Not determined.
πŸ“Š Bulk Density
Not available
βš–οΈ Density
1.26 g/cm3 (10.515 lbs/gal)
Critical Property
πŸ”₯ Flammability
Not determined.
πŸ“Š Upper Explosive Limit
Not determined
πŸ“Š Lower Explosive Limit
Not determined
πŸ“Š Explosive Limits
Not available
πŸ“Š Auto Ignition Temperature
Not determined
πŸ“Š Decomposition Temperature
Not determined
πŸ’§ Solubility
Not available
πŸ“Š Partition Coefficient
Not determined.
πŸ“Š Solubility In Water
Not determined
πŸ“Š Solubility In Fat
Not available
πŸ“Š Molecular Weight
Not available
πŸ“Š Voc Content
Not available
πŸ“Š Metal Corrosion
Not available
πŸ“Š Dynamic Viscosity
Not applicable.
πŸ“Š Kinematic Viscosity
Not applicable.
πŸ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Properly operating chemical fume hood designed for hazardous chemicals and having an average face velocity of at least 100 feet per minute.

🧀 Hand Protection

Impervious gloves. Check protective gloves prior to each use for their proper condition. The selection of suitable gloves not only depends on the material, but also on quality. Quality will vary from manufacturer to manufacturer. Penetration time of glove material (in minutes) Not determined

πŸ‘οΈ Eye Protection

Safety glasses

😷 Respiratory Protection

Use suitable respirator when high concentrations are present. Recommended filter device for short term use: Use a respirator with type N95 (USA) or PE (EN 143) cartridges as a backup to engineering controls. Risk assessment should be performed to determine if air-purifying respirators are appropriate. Only use equipment tested and approved under appropriate government standards.

🦺 Skin/Body Protection

Protective work clothing.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

πŸ“¦ Proper Shipping Name

Not applicable

⚠️ Transport Hazard Class

Not applicable

πŸ“‹ Packing Group

Not applicable

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for hydrolyzed?

The signal word for this substance is "no signal word".

What is the physical form of hydrolyzed?

hydrolyzed is a solid . It has odorless odor.

What is hydrolyzed used for?

SU24 Scientific research and development

What is the melting point of hydrolyzed?

The melting point is 200 Β°C (392 ΒΊF) and the boiling point is Not determined.