Product Name
Intergard 405 Red Part A
Product Code
EGA053

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Professional application of coatings and inks
Uses Advised Against
All Other Uses

Overview

Intergard 405 Red Part A is a red substance commonly used professional application of coatings and inks.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Flam. Liq. Category 3
Skin Corr. Category 2
Eye Dam. Category 1
Skin Sens. Category 1
Carc. Category 2
STOT SE Category 3
STOT RE Category 1

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS05 GHS Hazard Pictogram: Corrosive hazard - Materials that can cause severe skin burns and eye damage

GHS05

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H226: Flammable liquid and vapour.
  • H318: Causes serious eye damage.
  • H315: Causes skin irritation.
  • H317: May cause an allergic skin reaction.
  • Suspected of causing cancer.
  • H336: May cause drowsiness or dizziness.
  • Causes damage to organs through prolonged or repeated exposure.

Precautionary Statements

  • Obtain special instructions before use. Do not handle until all safety precautions have been read and understood. Use personal protective equipment as required. Wear protective gloves. Wear eye or face protection. Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Use explosion-proof electrical, ventilating, lighting and all material-handling equipment. Use only non-sparking tools. Take precautionary measures against static discharge. Keep container tightly closed. Use only outdoors or in a well-ventilated area. Do not breathe vapour. Do not eat, drink or smoke when using this product. Wash hands thoroughly after handling. Contaminated work clothing should not be allowed out of the workplace.
  • Get medical attention if you feel unwell. IF exposed or concerned: Get medical attention. IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. Call a POISON CENTER or physician if you feel unwell. IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water or shower. IF ON SKIN: Wash with plenty of soap and water. Take off contaminated clothing. If skin irritation or rash occurs: Get medical attention. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER or physician.
  • Store locked up. Store in a well-ventilated place. Keep cool.
  • Dispose of contents and container in accordance with all local, regional, national and international regulations.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

International Farg AB

manufacturer

๐Ÿ“

Holmedalen 3, Aspereds Industriomrade, SE-424 22 Angered, Sweden

๐ŸŒ

SE

๐Ÿ“ž

+46 (0) 31 928500

๐Ÿ“ 

+46 (0) 31 928530

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

International Farg AB

๐Ÿ“ž

+46 (0) 31 928500

๐ŸŒ

SE

International Farg AB

๐Ÿ“ž

+46 8 33 12 31

๐ŸŒ

SE

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Phenol, 4,4'- (1-methylethylidene)bis-, polymer with 2,2'-[ (1-methylethylidene)bis(4, 1-phenyleneoxymethylene)]bis [oxirane] xylene 25036-25-3 15-20% โš ๏ธ Hazardous
butan-1-ol 71-36-3 5-10% โš ๏ธ Hazardous
Talc , not containing talc (non-asbestos form) 14807-96-6 5-10% โœ“ Non-hazardous
ethylbenzene 100-41-4 0.1-5% โš ๏ธ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Remove victim to fresh air and keep at rest in a position comfortable for breathing. If it is suspected that fumes are still present, the rescuer should wear an appropriate mask or self-contained breathing apparatus. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Symptoms:

If not breathing, if breathing is irregular or if respiratory arrest occurs.

๐Ÿ–๏ธ Skin Contact

Wash with plenty of soap and water. Remove contaminated clothing and shoes. Wash contaminated clothing thoroughly with water before removing it, or wear gloves. Continue to rinse for at least 10 minutes.

Symptoms:

Chemical burns must be treated promptly by a physician.

๐Ÿ‘๏ธ Eye Contact

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes.

Symptoms:

Chemical burns must be treated promptly by a physician.

๐Ÿฝ๏ธ Ingestion/Swallowing

Wash out mouth with water. Remove dentures if any. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Never give anything by mouth to an unconscious person.

Symptoms:

Chemical burns must be treated promptly by a physician.

๐Ÿšจ Immediate Medical Attention Required

Get medical attention immediately. Call a poison center or physician.

Medical Treatment

Treat symptomatically. Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

โœ… Suitable Extinguishing Media

Use dry chemical, CO2, water spray (fog) or foam.

โŒ Unsuitable Extinguishing Media

Do not use water jet.

โš ๏ธ Specific Fire Hazards

Flammable liquid and vapour. In a fire or if heated, a pressure increase will occur and the container may burst, with the risk of a subsequent explosion. Runoff to sewer may create fire or explosion hazard.

๐Ÿ”ฅ Fire Fighting Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training. Move containers from fire area if this can be done without risk. Use water spray to keep fire-exposed containers cool.

๐Ÿ›ก๏ธ Firefighter Protection Equipment

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode.

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

๐Ÿšจ Emergency Procedures

No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilt material. Shut off all ignition sources. No flares, smoking or flames in hazard area. Do not breathe vapour or mist. Provide adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Put on appropriate personal protective equipment.

๐Ÿ’ง Small Spill Procedures

Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.

๐ŸŒŠ Large Spill Procedures

Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Approach the release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations.

๐ŸŒ Environmental Precautions

Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains and sewers. Inform the relevant authorities if the product has caused environmental pollution (sewers, waterways, soil or air).

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Red
๐ŸŽจ Colour
Red
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Solvent
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
Not applicable
๐ŸงŠ Melting Point
Not available
Critical Property
๐Ÿ’จ Boiling Point
Lowest known value: 136.16โ„ƒ (277.1ยฐF) (xylene)
Critical Property
๐Ÿ”ฅ Flash Point
Closed cup: 25โ„ƒ (77ยบF)
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
Not available
๐Ÿ“Š Vapor Density
1.59
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
Not available
๐Ÿ“Š Upper Explosive Limit
11.3%
๐Ÿ“Š Lower Explosive Limit
1.4%
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not available
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
Insoluble in the following materials: cold water
๐Ÿ“Š Partition Coefficient
Not available
๐Ÿ“Š Solubility In Water
Insoluble in the following materials: cold water
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not applicable
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

โš ๏ธ Handling Precautions

โ€ข Put on appropriate personal protective equipment (see Section 8).

โ€ข Persons with a history of skin sensitization problems should not be employed in any process in which this product is used.

โ€ข Avoid exposure - obtain special instructions before use.

โ€ข Do not handle until all safety precautions have been read and understood.

โ€ข Do not get in eyes or on skin or clothing.

โ€ข Do not breathe vapour or mist.

โ€ข Do not ingest.

โ€ข Use only with adequate ventilation.

โ€ข Wear appropriate respirator when ventilation is inadequate.

โ€ข Do not enter storage areas and confined spaces unless adequately ventilated.

โ€ข Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use.

โ€ข Store and use away from heat, sparks, open flame or any other ignition source.

โ€ข Use explosion-proof electrical (ventilating, lighting and material handling) equipment.

โ€ข Use only non-sparking tools.

โ€ข Take precautionary measures against electrostatic discharges.

โ€ข Empty containers retain product residue and can be hazardous.

โ€ข Do not reuse container.

๐Ÿช Storage Conditions

โ€ข Store in accordance with local regulations.

โ€ข Store in a segregated and approved area.

โ€ข Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink.

โ€ข Store locked up.

โ€ข Keep container tightly closed and sealed until ready for use.

โ€ข Containers that have been opened must be carefully resealed and kept upright to prevent leakage.

โ€ข Do not store in unlabelled containers.

๐Ÿงผ General Hygiene Measures

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas. See also Section 8 for additional information on hygiene measures.

๐Ÿ”ฅ Fire Prevention Measures

Eliminate all ignition sources.

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapour or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.

๐Ÿงค Hand Protection

Use chemical resistant gloves classified under Standard EN 374: Protective gloves against chemicals and micro-organisms. Recommended: Vitonยฎ or Nitrile gloves. When prolonged or frequently repeated contact may occur, a glove with a protection class of 6 (breakthrough time greater than 480 minutes according to EN 374) is recommended. When only brief contact is expected, a glove with a protection class of 2 or higher (breakthrough time greater than 30 minutes according to EN 374) is recommended. The user must check that the final choice of type of glove selected for handling this product is the most appropriate and takes into account the particular conditions of use, as included in the user's risk assessment. NOTICE: The selection of a specific glove for a particular application and duration of use in a workplace should also take into account all relevant workplace factors such as, but not limited to: Other chemicals which may be handled, physical requirements (cut/ puncture protection, dexterity, thermal protection), potential body reactions to glove materials, as well as the instructions/specifications provided by the glove supplier. Barrier creams may help to protect the exposed areas of the skin but should not be applied once exposure has occurred.

๐Ÿ‘๏ธ Eye Protection

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: chemical splash goggles and/or face shield. If inhalation hazards exist, a full-face respirator may be required instead.

๐Ÿ˜ท Respiratory Protection

Use a properly fitted, air-purifying or air-fed respirator complying with an approved standard if a risk assessment indicates this is necessary. Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator.

๐Ÿฆบ Skin/Body Protection

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. When there is a risk of ignition from static electricity, wear anti-static protective clothing. For the greatest protection from static discharges, clothing should include anti-static overalls, boots and gloves.

๐ŸŒ Environmental Exposure Controls

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

โœ… Chemical Stability

The product is stable.

โš ๏ธ Hazardous Reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

๐Ÿšซ Conditions to Avoid

Avoid all possible sources of ignition (spark or flame). Do not pressurise, cut, weld, braze, solder, drill, grind or expose containers to heat or sources of ignition.

๐Ÿงช Incompatible Materials

Reactive or incompatible with the following materials: oxidizing materials

๐Ÿ’จ Hazardous Decomposition Products

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

Ecological Information & Environmental Impact

Environmental toxicity, biodegradation, bioaccumulation, and ecological effects data

๐ŸŒฑ Ecotoxicity

Acute LC50 8500 ยตg/l Marine water for xylene; Acute LC50 13400 ยตg/l Fresh water and Acute EC50 1983 to 2072 mg/l Fresh water for butan-1-ol; Acute EC50 3.6 mg/l Fresh water, Acute LC50 18.4 to 25.4 mg/l Fresh water, and Acute LC50 5.1 to 5.7 mg/l Marine water for ethylbenzene.

๐ŸŒฑ Persistence and degradability

Aquatic half-life for ethylbenzene is not available. Photolysis is not available. Biodegradability is readily.

๐ŸŒฑ Bioaccumulative potential

LogPow for xylene is 3.12, BCF is 8.1 to 25.9, potential is low; LogPow for butan-1-ol is 1, BCF is not available, potential is low; LogPow for ethylbenzene is 3.6, BCF is 15, potential is low.

๐ŸŒฑ Mobility in soil

Soil/water partition coefficient (Koc) is not available.

๐ŸŒฑ Other adverse effects

No known significant effects or critical hazards.

Waste Disposal & Treatment Methods

Waste disposal procedures, treatment methods, and regulatory compliance requirements

โ™ป๏ธ Waste Treatment Methods

The generation of waste should be avoided or minimised wherever possible. Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements.

๐Ÿ—‚๏ธ Product Disposal Recommendations

Dispose of surplus and non-recyclable products via a licensed waste disposal contractor. Waste should not be disposed of untreated to the sewer unless fully compliant with the requirements of all authorities with jurisdiction.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

UN1263

๐Ÿ“ฆ Proper Shipping Name

PAINT

โš ๏ธ Transport Hazard Class

3 3

๐Ÿ“‹ Packing Group

III

๐Ÿšข IMDG Maritime Transport Precautions

Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Intergard 405 Red Part A?

The signal word for this substance is "danger".

What is the physical form of Intergard 405 Red Part A?

Intergard 405 Red Part A is a liquid appearing as red with red color. It has solvent odor.

What is the solubility of Intergard 405 Red Part A?

Insoluble in the following materials: cold water

What is Intergard 405 Red Part A used for?

Professional application of coatings and inks

What are the hazard statements for Intergard 405 Red Part A?

This substance has 7 hazard statements: H226: Flammable liquid and vapour. H318: Causes serious eye damage. H315: Causes skin irritation. H317: May cause an allergic skin reaction. Suspected of causing cancer. H336: May cause drowsiness or dizziness. Causes damage to organs through prolonged or repeated exposure.

What is the melting point of Intergard 405 Red Part A?

The melting point is Not available and the boiling point is Lowest known value: 136.16โ„ƒ (277.1ยฐF) (xylene).