NextSDS Logo
Safety Data Sheet EN

Lithium-Ion Rechargeable Battery Pack

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Lithium-Ion Rechargeable Battery Pack
Product Code
BL1850B

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

M

Makita U.S.A., Inc.

manufacturer

14930-C Northam Street, La Mirada, CA 90638

Emergency Contacts

CHEMTREC

1-800-424-9300

MAKITA

1-510-657-9881

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type Mixture

During charge process a lithium graphite intercalation phase is formed.

Chemical Name CAS Number Concentration Hazardous
Lithium Nickel Oxide 12325-84-7 25 - 35% No
Graphite [C] EC: 231-955-3 7782-42-5 20 - 30% No
Iron [Fe] EC: 231-096-4 7439-89-6 10 - 20% No
Copper and/or copper alloys and compounds (as Cu) EC: 231-159-6 7440-50-8 5 - 15% No
Lithium Cobalt Dioxide EC: 235-362-0 12190-79-3 1 - 5% No
Methylpropionaat EC: 209-060-4 554-12-1 1 - 5% Yes
aluminium substance with a Community workplace exposure limit EC: 231-072-3 7429-90-5 1 - 5% Yes
Lithium Hexaflourophosphate EC: 244-334-7 21324-40-3 1 - 3% No
4-Fluoro-1,3-dioxolan-2- one EC: 483-360-5 114435-02-8 1 - 3% No
Carbonzuur, dimethylester EC: 210-478-4 616-38-6 1 - 3% Yes
Polyethlene EC: 618-339-3 9002-88-4 1 - 3% No
Iron oxide EC: 215-168-2 1309-37-1 0.1 - 1% No
Boehmite (Al (OH)O) EC: 215-284-3 1318-23-6 0.1 - 1% No
NOIR DE CARBONE, AMORPHE EC: 231-153-3 1333-86-4 0.1 - 1% No
Nickel foam EC: 231-111-4 7440-02-0 0.1 - 1% Yes
1-methyl-2-pyrrolidon EC: 212-828-1 872-50-4 0.1 - 1% Yes
Aluminum lithium oxide (LiAlO) 11089-89-7 0.1 - 1% No
Chromium and chromium alloys or compounds (as Cr) EC: 231-157-5 7440-47-3 0.1 - 1% No
Lithiumcarbonaat, Li2CO3 EC: 209-062-5 554-13-2 0.1 - 1% No
ethylbenzene EC: 202-849-4 100-41-4 0.1 - 1% Yes

Notes

Because of the cell structure the dangerous ingredients will not be available if used properly.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

In case of inhalation of organic electrolyte mist, remove from exposure to fresh air. If necessary give oxygen. Get medical attention.

Skin contact

Remove contaminated clothing and wash before reuse. Immediately rinse contact area with plenty of clean water. Provide first aid to contacted area to prevent infection. Get medical attention.

Eye contact

Rinse eyes with plenty of water for at least 15 minutes and seek medical attention.

Ingestion

In case of ingestion of electrolyte don't induce vomiting. If patient is conscious and alert give 2~4 cupful's of milk or water. Never give anything by mouth to an unconscious person. Get medical attention immediately.

Immediate Medical Attention

Ensure that medical personnel are aware of the material(s) involved and take precautions to protect themselves.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Avoid charging batteries in areas where hydrogen gas accumulate. Use local exhaust ventilation to maintain concentrations of hydrogen below the Lower Explosive limit and collect and transport flammable gases in ventilation systems. Insure proper ventilation is present and electrolyte mist and vapours.

Hands

Wear nitrile butyl rubber, neoprene, or PVC glove during battery component disassembly. Discard contaminated work clothing after one work day.

Eyes

Wear ANSI approved safety glasses with side shield during normal use. Wear NIOSH approved face shield with safety glasses and H.V protection during intentional disassembly.

Respiratory

None required during normal use. Wear NIOSH or European Standard EN 149 approved full or half face piece (with goggles) respiratory protective equipment when necessary. In lack of oxygen (< 19.5%), wear the supplied-air respirator or self-contained oxygen breathing apparatus. In case exposed to particulate material, the respiratory protective equipments as follow are recommended; facepiece filtering respirator or air-purifying respirator, high-efficiency particulate air (HEPA) filter media or respirator equipped with powered fan, filter media of use (dust, mist, fume).

Skin/Body

Wear protective clothing during battery component disassembly. Discard contaminated work clothing after one work day.

Environmental

Not available

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Solid
Physical State Data
solid
State Under Standard Conditions
---
Appearance
Solid
Colour
Not available
Colour Intensity
---
Form
---
Odor
Odorless
Odor Threshold
Not available
Ph
Not available
Melting Point
Not available
Boiling Point
Not available
Flash Point
Not available
Freezing Point
Not available
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not available
Vapor Pressure
Insoluble.
Vapor Density
Not available
Relative Density
Not available
Bulk Density
---
Density
---
Flammability
Not available
Upper Explosive Limit
Not available
Lower Explosive Limit
Not available
Explosive Limits
---
Auto Ignition Temperature
Not available
Decomposition Temperature
Not available
Solubility
Not available
Partition Coefficient
Not available
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
Not available
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
Not available
Kinematic Viscosity
Not available
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
3480
Shipping Name
Lithium ion cells and batteries
Transport Class
9
Packing Group
II
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Lithium-Ion Rechargeable Battery Pack?

The signal word is no signal word.

What is the physical form of Lithium-Ion Rechargeable Battery Pack?

Lithium-Ion Rechargeable Battery Pack is a solid appearing as solid with not available color. It has odorless odor.

What is the solubility of Lithium-Ion Rechargeable Battery Pack?

Not available

What is the melting point of Lithium-Ion Rechargeable Battery Pack?

The melting point is Not available and the boiling point is Not available.

Compliance Scanner

Scan your compliance