NextSDS Logo
Safety Data Sheet EN

Plexar PX3236

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Plexar PX3236

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Manufacture of plastic articles by injection molding, extrusion or other conversion process.

Uses advised against

FDA Class III medical devices; European class III medical devices; Health Canada class IV Medical Devices; Applications involving permanent implantation into the body; Life-sustaining medical applications

Manufacturers & Suppliers

B

Basell Sales & Marketing Company B.V.

national supplier

Delftseplein 27E 3013 AA Rotterdam Netherlands

31 (0) 10 275 55 00

Emergency Contacts

Basell Sales & Marketing Company B.V.

+32 3 575 1235

National Poisons Information Service

+44 131 242 1383

24 hours all days

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Proprietary blend of polyolefinic polymers. Contains: Stabilizers

Chemical Name CAS Number Concentration Hazardous
Proprietary blend of polyolefinic polymers --- 99.5% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove person to fresh air. If signs/symptoms continue, get medical attention. In case of excessive inhalation of fumes that may be generated during heating of this material, move the person to fresh air. Keep person warm, if necessary give Cardio-Pulmonary Resuscitation (CPR)

Symptoms: soreness in the nose and throat and coughing.

Skin contact

If molten material contacts the skin, immediately flush with large amounts of water to cool the affected tissue and polymer. Do not attempt to peel polymer from skin as this will remove the skin.

Symptoms: Molten polymer may cause thermal burns.

Eye contact

Flush eyes thoroughly with water for several minutes and seek medical attention if discomfort persists. In case of eye contact with molten polymer: Continuously flush eye(s) with cool running water for at least 15 minutes. Beyond flushing, DO NOT attempt to remove the material adherent to the eye(s). Immediately seek medical attention.

Symptoms: Dust contact with the eyes can lead to mechanical irritation.

Immediate Medical Attention

If signs/symptoms continue, get medical attention. Obtain medical attention. Obtain immediate emergency medical attention if burn is deep or extensive. seek medical attention if discomfort persists. Immediately seek medical attention.

Medical Treatment

Treatment of overexposure should be directed at the control of symptoms and the clinical condition of the patient.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Follow the recommendations in international standard NFPA 654 (as amended and adopted) for equipment used to handle this product. Engineering controls, i.e. enclosed systems, should be used whenever feasible to maintain exposures below acceptable criteria. When such controls are not feasible, or sufficient to achieve full conformance, other engineering controls such as local exhaust ventilation should be used. Ensure that dust-handling systems (such as exhaust ducts, dust collectors, vessels, and processing equipment) are designed in a manner to prevent the escape of dust into the work area (i.e., there is no leakage from the equipment).

Hands

Wear gloves that provide thermal protection where there is a potential for contact with heated material.

Eyes

Dust service goggles should be worn to prevent mechanical injury or other irritation to eyes due to airborne particles which may result from handling this product.

Respiratory

Use process enclosures, local exhaust ventilation, or other engineering controls to keep airborne levels below recommended exposure limits. When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. Use appropriate respiratory protection where atmosphere exceeds recommended limits. Where workers could be exposed to dust concentrations above the exposure limit they must use appropriate certified respirators.

Skin/Body

Wear suitable protective clothing.

Environmental

See section 6.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
solid
Physical State Data
solid
State Under Standard Conditions
---
Appearance
Pellets.
Colour
Translucent to white
Colour Intensity
---
Form
Pellets.
Odor
Slight.
Odor Threshold
---
Ph
---
Melting Point
50 - 170 ℃
Boiling Point
Not applicable.
Flash Point
No Data Available.
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not applicable.
Vapor Pressure
Not applicable.
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
< 1 g/cm3
Flammability
Polymer will burn but does not easily ignite.
Upper Explosive Limit
Not applicable.
Lower Explosive Limit
The minimum explosive concentration (MEC) for polymer dust varies according to particle size distribution.
Explosive Limits
---
Auto Ignition Temperature
>300 ℃
Decomposition Temperature
not determined
Solubility
---
Partition Coefficient
No Data Available.
Solubility In Water
Insoluble.
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
Not applicable.
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Plexar PX3236?

The signal word is no signal word.

What is the physical form of Plexar PX3236?

Plexar PX3236 is a solid appearing as pellets. with translucent to white color. It has slight. odor.

What is Plexar PX3236 used for?

Manufacture of plastic articles by injection molding, extrusion or other conversion process.

What is the melting point of Plexar PX3236?

The melting point is 50 - 170 ℃ and the boiling point is Not applicable..