Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
GXH80032-PG * DURC MS ACCELE
Product Code
GXH80032-PG

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Industrial applications, Used by spraying, Coating.

Overview

GXH80032-PG * DURC MS ACCELE commonly used industrial applications, used by spraying, coating..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

PPG Industries Lackfabrik GmbH

undefined

Werner-Siemens-Strasse 1 D-76356 Weingarten Germany

DE

+49 7244 64 0

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Supplier

+49 (0) 202 78 2499

DE

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
polymeren
EC: 500-060-2
28182-81-2 35-50% Hazardous
n-Butyl acetate
EC: 204-658-1
123-86-4 35-50% Hazardous
3-Isocyanatomethyl-3,5,5trimethylcyclohexyl isocyanate, oligomers
EC: 500-125-5
53880-05-0 10-15% Hazardous
Oplosmiddelnafta (aardolie), lichte aromatische (<0,1 % benzeen)
EC: 265-199-0
64742-95-6 2.5-5% Hazardous
1,2,4-trimethylbenzene
EC: 202-436-9
95-63-6 1-2.5% Hazardous
2-METHOXY-1- METHYLETHYLACETAAT
EC: 203-603-9
108-65-6 1-5% Hazardous
Xyleen (mengsel)
EC: 215-535-7
1330-20-7 1-5% Hazardous
1,3,5-TRIMETHYLBENZENE, Mesitylene stof waarvoor binnen de Gemeenschap een blootstellingsgrens op de werkvloer geldt
EC: 203-604-4
108-67-8 0.25-2.5% Hazardous
1-propylbenzene
EC: 203-132-9
103-65-1 0.25% Hazardous
isopropylbenzene (cumene)
EC: 202-704-5
98-82-8 0.25% Hazardous

Additional Information

See Section 16 for the full text of the R-phrases declared above. See Section 16 for the full text of the H statements declared above. Occupational exposure limits, if available, are listed in Section 8. SUB codes represent substances without registered CAS Numbers.

Composition Notes

There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment and hence require reporting in this section.

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Remove to fresh air. Keep person warm and at rest. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel.

Symptoms:

Harmful by inhalation. Irritating to respiratory system. Exposure to decomposition products may cause a health hazard. Adverse symptoms may include: respiratory tract irritation, coughing.

Skin Contact

Remove contaminated clothing and shoes. Wash skin thoroughly with soap and water or use recognised skin cleanser.

Symptoms:

Defatting to the skin. May cause skin dryness and irritation. May cause sensitisation by skin contact. Adverse symptoms may include: irritation, redness, dryness, cracking.

Eye Contact

Check for and remove any contact lenses. Immediately flush eyes with running water for at least 15 minutes, keeping eyelids open. Seek immediate medical attention.

Symptoms:

May cause eye irritation.

Ingestion/Swallowing

If swallowed, seek medical advice immediately and show the container or label. Keep person warm and at rest. Do NOT induce vomiting.

Symptoms:

No known significant effects or critical hazards.

Immediate Medical Attention Required

Seek immediate medical attention for eye contact. If swallowed, seek medical advice immediately.

Medical Treatment

No specific treatment.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Physical State
Liquid.
Critical Property
Physical State Data
liquid
State Under Standard Conditions
Not available
Appearance
Not available
Colour
Colourless.
Colour Intensity
Not available
Form
Not available
Odor
Not available.
Odor Threshold
Not available.
Ph
Not available.
Melting Point
Not available.
Critical Property
Boiling Point
>37.78C
Critical Property
Flash Point
Closed cup: 26C
Critical Property
Freezing Point
Not available.
Softening Point
Not available
Solidification Point
Not available
Cloud Point
Not available
Crystallisation Point
Not available
Relative Evaporation Rate
Not available
Evaporation Rate
Not available.
Vapor Pressure
Highest known value: 1.5 kPa (11.3 mm Hg) (at 20C) (n-butyl acetate). Weighted average: 1.26 kPa (9.45 mm Hg) (at 20C)
Vapor Density
Highest known value: 4.6 (Air = 1) (2-methoxy-1-methylethyl acetate). Weighted average: 4.02 (Air = 1)
Relative Density
Not available.
Bulk Density
Not available
Density
Not available
Flammability
Not available.
Upper Explosive Limit
10%
Lower Explosive Limit
0.7%
Explosive Limits
Not available
Auto Ignition Temperature
Not available.
Decomposition Temperature
Not available.
Solubility
Insoluble in the following materials: cold water.
Partition Coefficient
Not available.
Solubility In Water
Insoluble in the following materials: cold water.
Solubility In Fat
Not available
Molecular Weight
Not available
Voc Content
Not available
Metal Corrosion
Not available
Dynamic Viscosity
Not available
Kinematic Viscosity
Not available
Properties Status
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapour or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.

Hand Protection

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated. Gloves: butyl rubber

Eye Protection

Safety glasses with side shields.

Respiratory Protection

If workers are exposed to concentrations above the exposure limit, they must use appropriate, certified respirators. Use a properly fitted, air-purifying or air-fed respirator complying with an approved standard if a risk assessment indicates this is necessary. Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator.

Skin/Body Protection

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. When there is a risk of ignition from static electricity, wear anti-static protective clothing. For the greatest protection from static discharges, clothing should include anti-static overalls, boots and gloves. Refer to European Standard EN 1149 for further information on material and design requirements and test methods. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental Exposure Controls

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

UN1263

Proper Shipping Name

PAINT

Transport Hazard Class

3

Packing Group

III

ADR Transport Precautions

Transport within users premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

IMDG Maritime Transport Precautions

Transport within users premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

IATA Air Transport Precautions

Transport within users premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for GXH80032-PG * DURC MS ACCELE?

The signal word for this substance is "no signal word".

What is the physical form of GXH80032-PG * DURC MS ACCELE?

GXH80032-PG * DURC MS ACCELE is a liquid. with colourless. color. It has not available. odor.

What is the solubility of GXH80032-PG * DURC MS ACCELE?

Insoluble in the following materials: cold water.

What is GXH80032-PG * DURC MS ACCELE used for?

Industrial applications, Used by spraying, Coating.

What are the hazard statements for GXH80032-PG * DURC MS ACCELE?

This substance has 1 hazard statements:

What is the melting point of GXH80032-PG * DURC MS ACCELE?

The melting point is Not available. and the boiling point is >37.78C.