NextSDS Logo
Bl

Blygold PoluAl

NO SIGNAL WORD Liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Blygold PoluAl

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
One-component moisture curing polyurethane aluminum coating developed for corrosion protection at heatexchangers

Overview

Blygold PoluAl commonly used one-component moisture curing polyurethane aluminum coating developed for corrosion protection at heatexchangers.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Blygold International BV

manufacturer

๐Ÿ“

Hoofdveste 13 3992 DH HOUTEN THE NETHERLANDS

๐ŸŒ

NL

๐Ÿ“ž

#31 (0)30-6344344

๐Ÿ“ 

#31 (0)30-6344300

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

General Composition

Preparation containing aluminumparts consisting of:

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Aromatic carbureted hydrogen 64742-95-6 25% โš ๏ธ Hazardous
Glycolether ester 108-65-6 12.5% โš ๏ธ Hazardous
Diphenylmethanedi-isocyanate 26447-40-5 25% โš ๏ธ Hazardous
Toluenedi-isocyanatepolymer Confidential 5-25% โœ“ Non-hazardous
Toluenedi-isocyanate 26471-62-5 0.5% โš ๏ธ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Remove to fresh air. When an early convalescence not happens or irritating of the respiratory system takes place, seek medical advice.

๐Ÿ–๏ธ Skin Contact

Flush with lots of water and wash with water and soap. Call a physician if irritation persists.

๐Ÿ‘๏ธ Eye Contact

Irrigate with flowing water immediately and consult medical personal.

๐Ÿฝ๏ธ Ingestion/Swallowing

Seek immediately medical advice.

๐Ÿšจ Immediate Medical Attention Required

Seek medical advice immediately for ingestion. Consult medical personal for eye contact. Call a physician if skin irritation persists. Seek medical advice if an early convalescence does not happen or if irritation of the respiratory system takes place after inhalation.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Aluminum
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Solvent
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
Not available
๐ŸงŠ Melting Point
Not available
๐Ÿ’จ Boiling Point
Ca. 140 C
Critical Property
๐Ÿ”ฅ Flash Point
46 C
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
0,00001 mbar at 20
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
1,07 at 20
Critical Property
๐Ÿ”ฅ Flammability
Not available
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
> 400 C
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not available
๐Ÿ“Š Solubility In Water
Insoluble
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
1500 mPa.s at 20
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Use only in well-ventilated areas.

๐Ÿงค Hand Protection

protective gloves

๐Ÿ‘๏ธ Eye Protection

eye/face protection

๐Ÿ˜ท Respiratory Protection

Protect the breathing with a mask type ABEK, when the MAC-value is exceeded.

๐Ÿฆบ Skin/Body Protection

suitable clothing

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

1263

๐Ÿ“ฆ Proper Shipping Name

Paint or paint related material

๐Ÿ“‹ Packing Group

3/TII

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Blygold PoluAl?

The signal word for this substance is "no signal word".

What is the physical form of Blygold PoluAl?

Blygold PoluAl is a liquid with aluminum color. It has solvent odor.

What is Blygold PoluAl used for?

One-component moisture curing polyurethane aluminum coating developed for corrosion protection at heatexchangers