NextSDS Logo
Cu

Curon 13 SCC

NO SIGNAL WORD Solid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Curon 13 SCC

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Industrial refractory application
Uses Advised Against
No information available

Overview

Curon 13 SCC is a dry, grey powder substance commonly used industrial refractory application.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

  • P261: Avoid breathing dust/fume/gas/mist/vapors/spray
  • P280: Wear eye protection/ face protection
  • P285: In case of inadequate ventilation wear respiratory protection
  • IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing
  • IF ON SKIN: Wash with plenty of soap and water

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Gouda Refractories

manufacturer

๐Ÿ“

Goudkade 21 2802 AA Gouda The Netherlands

๐ŸŒ

NL

๐Ÿ“ž

+31(0)182591400

๐Ÿ“ 

+31(0)182583959

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

NVIC

๐Ÿ“ž

+31887558000

๐ŸŒ

NL

๐Ÿ’ก

Only for the purpose of informing medical personnel in case of acute intoxications.

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Alumina cement 65997-16-2 25% โœ“ Non-hazardous
Aluminum silicate (calcined) 1327-43-1 50% โœ“ Non-hazardous
Calcium Aluminates 65997-16-2 50% โœ“ Non-hazardous
Barium sulfate 7727-43-7 25% โœ“ Non-hazardous

Composition Notes

This product does not contain candidate substances of very high concern at concentration >= 0.1 (regulation (EC) No. 1272/2008 (REACH), Article 59).

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Remove to fresh and dust free area

๐Ÿ–๏ธ Skin Contact

Wash skin with soap and water. In the case of skin irritation or allergic reactions see a doctor.

Symptoms:

Mild skin irritant.

๐Ÿ‘๏ธ Eye Contact

Rinse thoroughly with plenty water for at least 15 minutes, lifting lower and upper eye lids. Consult a doctor.

Symptoms:

Mild eye irritant.

๐Ÿฝ๏ธ Ingestion/Swallowing

Clean mouth with water and drink afterwards plenty of water.

๐Ÿšจ Immediate Medical Attention Required

Treat symptomatically.

Medical Treatment

Treat symptomatically.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Solid
Critical Property
๐Ÿ“Š Physical State Data
solid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Dry, grey powder
๐ŸŽจ Colour
grey
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Not available
๐Ÿ“Š Odor Threshold
No information available
๐Ÿงช Ph
7-10 aqueous solution. Not available
๐ŸงŠ Melting Point
1500 [ [ o] C]
Critical Property
๐Ÿ’จ Boiling Point
No data available
Critical Property
๐Ÿ”ฅ Flash Point
No data available
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
No data available
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
1800 [kg/m [3] ]
๐Ÿ“Š Bulk Density
1800 [kg/m [3] ]
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
Not available
๐Ÿ“Š Upper Explosive Limit
No data available
๐Ÿ“Š Lower Explosive Limit
No data available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Does not ignite
๐Ÿ“Š Decomposition Temperature
None known
๐Ÿ’ง Solubility
Slightly soluble
๐Ÿ“Š Partition Coefficient
No data available
๐Ÿ“Š Solubility In Water
No data available Insoluble
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
No data available
๐Ÿ“Š Kinematic Viscosity
No data available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿงค Hand Protection

Protective suitable gloves are recommended.

๐Ÿ‘๏ธ Eye Protection

Eye protection must conform to standard EN166. Safety glasses with side-shields or goggles to prevent dust and particles from entering the eyes.

๐Ÿ˜ท Respiratory Protection

No protective equipment is needed under normal conditions. If exposure limits are exceeded or irritation is experiences, ventilation and evacuation may be required.

๐Ÿฆบ Skin/Body Protection

No special protective equipment required.

๐ŸŒ Environmental Exposure Controls

Avoid dust formation. No information available.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

Not regulated

๐Ÿ“ฆ Proper Shipping Name

Not regulated

โš ๏ธ Transport Hazard Class

Not regulated

๐Ÿ“‹ Packing Group

Not regulated

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Curon 13 SCC?

The signal word for this substance is "no signal word".

What is the physical form of Curon 13 SCC?

Curon 13 SCC is a solid appearing as dry, grey powder with grey color.

What is the solubility of Curon 13 SCC?

Slightly soluble

What is Curon 13 SCC used for?

Industrial refractory application

What is the melting point of Curon 13 SCC?

The melting point is 1500 [ [ o] C] and the boiling point is No data available.