NextSDS Logo
WD

WDS UltraShell

NO SIGNAL WORD SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
WDS UltraShell

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Application as thermal insulation, heat shields, heat containment, gaskets and expansion joints in industrial furnaces, ovens, kilns, boilers and other process equipment and in the aerospace, automotive and appliance industries, and as passive fire protection systems and firestops.

Overview

WDS UltraShell is a molded fibrous sheet or form substance commonly used application as thermal insulation, heat shields, heat containment, gaskets and expansion joints in industrial furnaces, ovens, kilns, boilers and other process equipment and in the aerospace, automotive and appliance industries, and as passive fire protection systems and firestops..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Morgan Advanced Materials company logo - Safety Data Sheet supplier organization

Morgan Advanced Materials

manufacturer

P. O. Box 923; Dept. 300 Augusta, GA 30903-0923

US

706-796-4200

706-560-4054

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Morgan Advanced Materials

1-800-722-5681

US

For Product Stewardship and Emergency Information

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Silica Fume (Amorphous) N/A 50-80% Non-hazardous
SILICON CARBIDE POWDER
EC: 206-991-8
409-21-2 5-20% Non-hazardous
Silica Fiber N/A 10% Non-hazardous
Aluminium Film N/A 10% Non-hazardous
Graphite/Acetylene Black
EC: 215-691-6
1344-28-1 5% Non-hazardous

Additional Information

Impurities and Stabilizing Additives: Not applicable.

Composition Notes

See Section 8 "Exposure Controls / Personal Protection" for exposure guidelines

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Breathe fresh air.

Symptoms:

Irritation or soreness in the nose or throat.

Skin Contact

Wash the affected area gently with soap and water. A skin cream or lotion after washing may be helpful. Do not rub or scratch the exposed skin. Changing into clean clothing is recommended.

Symptoms:

Skin rash develops due to mechanical irritation.

Eye Contact

Flush with large amounts of water for at least 15 minutes. Do not rub eyes.

Symptoms:

Inflammation due to mechanical irritation.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Physical State
Not available
Physical State Data
Not available
State Under Standard Conditions
Not available
Appearance
Molded fibrous sheet or form
Colour
Not available
Colour Intensity
Not available
Form
Not available
Odor
Not applicable
Odor Threshold
Not applicable
Ph
Not applicable
Melting Point
>2000F (1093C)
Critical Property
Boiling Point
Not applicable
Critical Property
Flash Point
Not applicable
Critical Property
Freezing Point
Not available
Softening Point
Not available
Solidification Point
Not available
Cloud Point
Not available
Crystallisation Point
Not available
Relative Evaporation Rate
Not available
Evaporation Rate
Not applicable
Vapor Pressure
Not applicable
Vapor Density
Not applicable
Relative Density
Not applicable
Bulk Density
Not available
Density
Not available
Flammability
Not applicable
Upper Explosive Limit
Not applicable
Lower Explosive Limit
Not applicable
Explosive Limits
Not available
Auto Ignition Temperature
Not applicable
Decomposition Temperature
Not applicable
Solubility
Slight
Partition Coefficient
Not applicable
Solubility In Water
Not available
Solubility In Fat
Not available
Molecular Weight
Not available
Voc Content
Not available
Metal Corrosion
Not available
Dynamic Viscosity
Not available
Kinematic Viscosity
Not available
Properties Status
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

It is prudent to reduce exposure to respirable dusts to the lowest attainable level through the use of engineering controls such as ventilation and dust collection devices. Effective technologies to control respirable dust are available. These include local exhaust ventilation, point of generation dust collection, down draft workstations, emissions controlling tool designs and materials handling equipment.

Hand Protection

Wear gloves as necessary to prevent skin irritation.

Eye Protection

Wear goggles/safety glasses with sideshields

Respiratory Protection

When engineering and/or administrative controls are insufficient to maintain workplace concentrations below the PEL/REG or OEL, the use of appropriate respiratory protection, pursuant to the requirements of OSHA Standards 29 CFR 1910.134 and 29 CFR 1926.103, is recommended. A NIOSH certified respirator with a filter efficiency of at least 95% should be used. The 95% filter efficiency recommendation is based on NIOSH respirator selection logic sequence for exposure to particulates. Selection of filter efficiency (i.e. 95%, 99% or 99.97%) depends on how much filter leakage can be accepted and the concentration of airborne contaminants. Other factors to consider are the NIOSH filter series N, R or P. (N) Not resistant to oil, (R) Resistant to oil and (P) oil Proof. These recommendations are not designed to limit informed choices, provided that respiratory protection decisions comply with 29 CFR 1910.134. The evaluation of workplace hazards and the identification of appropriate respiratory protection is best performed, on a case by case basis, by a qualified industrial hygienist.

Skin/Body Protection

Wear long-sleeved, loose fitting clothing and hat as necessary to prevent skin irritation.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for WDS UltraShell?

The signal word for this substance is "no signal word".

What is the solubility of WDS UltraShell?

Slight

What is WDS UltraShell used for?

Application as thermal insulation, heat shields, heat containment, gaskets and expansion joints in industrial furnaces, ovens, kilns, boilers and other process equipment and in the aerospace, automotive and appliance industries, and as passive fire protection systems and firestops.

What is the melting point of WDS UltraShell?

The melting point is >2000F (1093C) and the boiling point is Not applicable.