Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
WDS UltraShell is a molded fibrous sheet or form substance commonly used application as thermal insulation, heat shields, heat containment, gaskets and expansion joints in industrial furnaces, ovens, kilns, boilers and other process equipment and in the aerospace, automotive and appliance industries, and as passive fire protection systems and firestops..
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
GHS Hazard Pictograms & Safety Symbols
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
Precautionary Statements
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
Morgan Advanced Materials
manufacturer
P. O. Box 923; Dept. 300 Augusta, GA 30903-0923
US
706-796-4200
706-560-4054
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Morgan Advanced Materials
1-800-722-5681
US
For Product Stewardship and Emergency Information
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Chemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Silica Fume (Amorphous) | N/A | 50-80% | โ Non-hazardous |
| SILICON CARBIDE POWDER EC: 206-991-8 | 409-21-2 | 5-20% | โ Non-hazardous |
| Silica Fiber | N/A | 10% | โ Non-hazardous |
| Aluminium Film | N/A | 10% | โ Non-hazardous |
| Graphite/Acetylene Black EC: 215-691-6 | 1344-28-1 | 5% | โ Non-hazardous |
Additional Information
Impurities and Stabilizing Additives: Not applicable.
Composition Notes
See Section 8 "Exposure Controls / Personal Protection" for exposure guidelines
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
๐ซ Inhalation Exposure
Breathe fresh air.
Symptoms:
Irritation or soreness in the nose or throat.
๐๏ธ Skin Contact
Wash the affected area gently with soap and water. A skin cream or lotion after washing may be helpful. Do not rub or scratch the exposed skin. Changing into clean clothing is recommended.
Symptoms:
Skin rash develops due to mechanical irritation.
๐๏ธ Eye Contact
Flush with large amounts of water for at least 15 minutes. Do not rub eyes.
Symptoms:
Inflammation due to mechanical irritation.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
๐ญ Engineering Controls
It is prudent to reduce exposure to respirable dusts to the lowest attainable level through the use of engineering controls such as ventilation and dust collection devices. Effective technologies to control respirable dust are available. These include local exhaust ventilation, point of generation dust collection, down draft workstations, emissions controlling tool designs and materials handling equipment.
๐งค Hand Protection
Wear gloves as necessary to prevent skin irritation.
๐๏ธ Eye Protection
Wear goggles/safety glasses with sideshields
๐ท Respiratory Protection
When engineering and/or administrative controls are insufficient to maintain workplace concentrations below the PEL/REG or OEL, the use of appropriate respiratory protection, pursuant to the requirements of OSHA Standards 29 CFR 1910.134 and 29 CFR 1926.103, is recommended. A NIOSH certified respirator with a filter efficiency of at least 95% should be used. The 95% filter efficiency recommendation is based on NIOSH respirator selection logic sequence for exposure to particulates. Selection of filter efficiency (i.e. 95%, 99% or 99.97%) depends on how much filter leakage can be accepted and the concentration of airborne contaminants. Other factors to consider are the NIOSH filter series N, R or P. (N) Not resistant to oil, (R) Resistant to oil and (P) oil Proof. These recommendations are not designed to limit informed choices, provided that respiratory protection decisions comply with 29 CFR 1910.134. The evaluation of workplace hazards and the identification of appropriate respiratory protection is best performed, on a case by case basis, by a qualified industrial hygienist.
๐ฆบ Skin/Body Protection
Wear long-sleeved, loose fitting clothing and hat as necessary to prevent skin irritation.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for WDS UltraShell?
The signal word for this substance is "no signal word".
What is the solubility of WDS UltraShell?
Slight
What is WDS UltraShell used for?
Application as thermal insulation, heat shields, heat containment, gaskets and expansion joints in industrial furnaces, ovens, kilns, boilers and other process equipment and in the aerospace, automotive and appliance industries, and as passive fire protection systems and firestops.
What is the melting point of WDS UltraShell?
The melting point is >2000F (1093C) and the boiling point is Not applicable.