NextSDS Logo
Wa

WaveTrace [TM] Composit K5 Karl Fischer reagent

NO SIGNAL WORD SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
WaveTrace [TM] Composit K5 Karl Fischer reagent
Product Code
31176

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Overview

WaveTrace [TM] Composit K5 Karl Fischer reagent .

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word (Warning/Danger)

Hazard Classifications

Flam. Liq. Category 4 H227
Acute Tox. Category 5 H303
Acute Tox. Category 5 H333
Acute Tox. Category 5 H313
Repr. Category 1B H360

GHS Hazard Pictograms & Safety Symbols

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H227: Combustible liquid
  • H303: May be harmful if swallowed
  • H313: May be harmful in contact with skin
  • H333: May be harmful if inhaled
  • H360: May damage the unborn child.

Precautionary Statements

  • P201: Obtain special instructions before use.
  • P210: Keep away from heat/sparks/open flames/hot surfaces. No smoking.
  • P280: Wear protective gloves/eye protection/face protection.
  • P312: Call a POISON CENTER or doctor/physician if you feel unwell.
  • P370+P378: In case of a fire: Use water spray for extinction.
  • P308+P313: IF exposed or concerned: Get medical advice/attention.
  • P403+P235: Store in a wellventilated place. Keep cool.
  • P501: Dispose of contents/container to an approved waste disposal plant.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Quveon, Inc.

undefined

๐Ÿ“

599 Raleigh Road Suite C Henderson, NC 27536 USA

๐ŸŒ

US

๐Ÿ“ž

1 800 471 3575

๐Ÿ“ 

1 213 283 3909

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

1 800 424 9300

๐ŸŒ

US

๐Ÿ’ก

(CCN812765)

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Imidazole 288324 10-20% โš ๏ธ Hazardous
Sulfur Dioxide 7446095 5-20% โš ๏ธ Hazardous
Iodine 7553562 5-15% โš ๏ธ Hazardous
2(2ethoxyethoxy)ethanol 111900 60-90% โœ“ Non-hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

If breathed in, move the person to fresh air. If not breathing, give artificial respiration. Consult a physician.

๐Ÿ–๏ธ Skin Contact

Wash off with soap and plenty of water. Consult a physician.

๐Ÿ‘๏ธ Eye Contact

Rinse thoroughly with plenty of water.

๐Ÿฝ๏ธ Ingestion/Swallowing

Do NOT induce vomiting. Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Not available
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
dark brown
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
liquid
๐Ÿ‘ƒ Odor
Not available
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
5.0 6.0 at 20 C (68 F)
๐ŸงŠ Melting Point
no data available
Critical Property
๐Ÿ’จ Boiling Point
202 C (395 F) at 1013 hPa (760 mmHg)
Critical Property
๐Ÿ”ฅ Flash Point
92 C (197 F) closed cup
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
Not available
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
1.10 g/cm3
Critical Property
๐Ÿ”ฅ Flammability
Not available
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
no data available
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not available
๐Ÿ“Š Solubility In Water
no data available
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits.

๐Ÿงค Hand Protection

Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching gloves outer surface) to avoid skin contact with the product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands.

๐Ÿ‘๏ธ Eye Protection

Tightly fitting safety goggles or safety glasses with side shields. Use equipment for eye protection tested and approved under appropriate government standards.

๐Ÿ˜ท Respiratory Protection

Where risk assessment shows air purifying respirators are appropriate, use a fullface respirator with multipurpose combination (US) or type AXBEK (EN 14387) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a fullface supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).

๐Ÿฆบ Skin/Body Protection

The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

3082

๐Ÿ“ฆ Proper Shipping Name

Environmentally hazardous substance, liquid, n.o.s. (2(2 ethoxyethoxy)ethanol)

โš ๏ธ Transport Hazard Class

9

๐Ÿ“‹ Packing Group

III

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for WaveTrace [TM] Composit K5 Karl Fischer reagent?

The signal word for this substance is "no signal word".

What are the hazard statements for WaveTrace [TM] Composit K5 Karl Fischer reagent?

This substance has 5 hazard statements: H227: Combustible liquid H303: May be harmful if swallowed H313: May be harmful in contact with skin H333: May be harmful if inhaled H360: May damage the unborn child.

What is the melting point of WaveTrace [TM] Composit K5 Karl Fischer reagent?

The melting point is no data available and the boiling point is 202 C (395 F) at 1013 hPa (760 mmHg).