NextSDS Logo
FL

FLECAINIDE ACETATE CRS

NO SIGNAL WORD SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
FLECAINIDE ACETATE CRS
Product Code
F0120000

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
For laboratory tests and assays only, as described in the European Pharmacopoeia.

Overview

FLECAINIDE ACETATE CRS is a white or almost white, very hygroscopic, crystalline powder. substance commonly used for laboratory tests and assays only, as described in the european pharmacopoeia..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

European Directorate for the Quality of Medicines & HealthCare company logo - Safety Data Sheet supplier organization

European Directorate for the Quality of Medicines & HealthCare

global supplier

๐Ÿ“

7, Alle Kastner CS 30026, F-67081 Strasbourg

๐ŸŒ

FR

๐Ÿ“ž

+33 (0)3 88 41 20 35

๐Ÿ“ 

+ 33 (0)3 88 41 27 71

๐ŸŒ www.edqm.eu

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Flecainide acetate
EC: 258-997-5
54143-56-5 Not specified โš ๏ธ Hazardous

Composition Notes

NB: Sodium channel blocking agent, class I anti-arrhythmic agent.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Remove to fresh air. If breathing becomes difficult, call a physician. If breathing stops, give oxygen.

๐Ÿ–๏ธ Skin Contact

Flush with copious amounts of water and soap for at least 15 minutes. Remove contaminated clothing and shoes.

๐Ÿ‘๏ธ Eye Contact

Assure adequate flushing by separating the eyelids with fingers. Flush with copious amounts of water for at least 15 minutes.

๐Ÿฝ๏ธ Ingestion/Swallowing

Wash out mouth with water and administer fresh water provided that the person is conscious. Monitor breathing and pulse.

๐Ÿšจ Immediate Medical Attention Required

In case of reactions described in hazards identification or other severe, immediate or persisting symptoms seek medical advice and call the nearest poison centre. Show the label and this safety data sheet.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Not available
๐Ÿ“Š Physical State Data
solid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
White or almost white, very hygroscopic, crystalline powder.
๐ŸŽจ Colour
White or almost white
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
crystalline powder
๐Ÿ‘ƒ Odor
Not available
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
6.7-7.1 (2.5% in water)
๐ŸงŠ Melting Point
146 152C
Critical Property
๐Ÿ’จ Boiling Point
Not available
๐Ÿ”ฅ Flash Point
No data available
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
Not available
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
Not available
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not available
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
Soluble in water and in anhydrous ethanol. It is freely soluble in dilute acetic acid and practically insoluble in dilute hydrochloric acid.
๐Ÿ“Š Partition Coefficient
No data available
๐Ÿ“Š Solubility In Water
Soluble in water
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Handling of small quantities in fume hood recommended. Mechanical exhaust, safety shower and eye bath required.

๐Ÿงค Hand Protection

Compatible chemical-resistant gloves.

๐Ÿ‘๏ธ Eye Protection

Wear protective chemical safety goggles.

๐Ÿ˜ท Respiratory Protection

Protecting mask (filter P2).

๐Ÿฆบ Skin/Body Protection

Wear protective coat.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for FLECAINIDE ACETATE CRS?

The signal word for this substance is "no signal word".

What is the solubility of FLECAINIDE ACETATE CRS?

Soluble in water and in anhydrous ethanol. It is freely soluble in dilute acetic acid and practically insoluble in dilute hydrochloric acid.

What is FLECAINIDE ACETATE CRS used for?

For laboratory tests and assays only, as described in the European Pharmacopoeia.

What is the melting point of FLECAINIDE ACETATE CRS?

The melting point is 146 152C .