Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- FELDSPAR
- Chemical Name
- FELDSPAR
Regulatory Identifiers
- CAS Number
- N/A
- REACH No.
- Exempted in accordance with Annex V.7
Identified Uses
Main applications (non exhaustive list): paint, ceramics, glass fibre, adhesives, plastics, rubber sealants, special concrete, manufacture of silicon, ferrosilicon and ironoxide pellets. Additive in production of cement and concrete. Fluxing material. Sport & Leisure.
Uses advised against
No use identified in Section 1.2. is advised against.
Manufacturers & Suppliers
Minerali Industriali S.r.l.
manufacturer
Piazza Martiri della Libertà n.4 - 28100 Novara
Emergency Contacts
Emergency Contact
112
Minerali Industriali S.r.l.
+39-0321-377600
NO
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Free crystalline silica (fine fraction) EC: 238-878-4 | 14808-60-7 | 1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Movement of the exposed individual from the area to fresh air is recommended.
Rinse with copious quantities of water and seek medical attention if irritation persists.
Medical Treatment
No specific actions are required.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
No specific extinguishing media is needed.
No restriction on the extinguishing media to be used.
Non combustible.
Firefighter Protection
No specific fire-fighting protection is required.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid airborne dust generation.
No special requirements.
Avoid dry sweeping and use water spraying or vacuum cleaning systems (with high-efficiency particulate air filter)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid airborne dust generation. Handle packaged products carefully to prevent accidental bursting.
Keep containers closed and store packaged products so as to prevent accidental bursting. Minimise airborne dust generation and prevent wind dispersal during loading and unloading.
Do not eat, drink or smoke when using this product. Wash hands thoroughly after handling. Remove contaminated clothing and protective equipment before entering eating areas. Shower and change clothes at end of work shift.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Minimise airborne dust generation. Use process enclosures, local exhaust ventilation or other engineering controls to keep airborne levels below specified exposure limits. If user operations generate dust, fumes or mist, use ventilation to keep exposure to airborne particles below the exposure limit. Apply organisational measures, e.g. by isolating personnel from dusty areas.
Appropriate protection (e.g. gloves, barrier cream) is recommended for workers who suffer from dermatitis or sensitive skin. Wash hands at the end of each work session.
Wear safety glasses with side-shields in circumstances where there is a risk of penetrative eye injuries.
The use of half or full face masks with filters against particles of category 2 or 3 (FP2 - FP3) is recommended. See EN 143: 2000 - Respiratory protective devices. Particle filters
No specific requirement. For hands, see below. Appropriate protection (e.g. protective clothing, barrier cream) is recommended for workers who suffer from dermatitis or sensitive skin.
Avoid wind dispersal.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Chemically stable.
Inert, not reactive.
No hazardous reactions.
Not relevant.
No particular incompatibility.
Not relevant.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Where possible, recycling is preferable to disposal. Can be disposed of in compliance with local regulations.
Where possible, recycling is preferable to disposal. Can be disposed of in compliance with local regulations.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Exempted from REACH Registration in accordance with Annex V.7. of Regulation (EC) 1907/2006.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for FELDSPAR?
The signal word is no signal word.
What is the physical form of FELDSPAR?
FELDSPAR is a solid appearing as solid . It has odourless odor.
What is the solubility of FELDSPAR?
Solubility in hydrofluoric acid: Yes