Product Name
CORE RANGE GLAZE ST.PINK CT1108
Product Form
Pigment
Product Code
CORE RANGE GLAZE ST.PINK CT1108

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Pigment

Overview

CORE RANGE GLAZE ST.PINK CT1108 commonly used pigment.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word (Void)

Hazard Classifications

Not Classified

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Fenzi AGT Netherlands B.V.

manufacturer

Fregatweg 38 6222 NZ Maastricht, The Netherlands

NL

+31 43 3525400

+31 43 3525555

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

+31 43 3525408

NL

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Mixture of naturally occurring raw materials, sintered at high temperatures

Additional Information

For the wording of the listed hazard phrases refer to section 16.

Composition Notes

Hazardous components: Void

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Eye Contact

Rinse opened eye for several minutes under running water.

Ingestion/Swallowing

In case of persistent symptoms consult doctor.

Immediate Medical Attention Required

No further relevant information available.

Medical Treatment

No further relevant information available.

Fire Safety

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

Suitable Extinguishing Media

Use fire fighting measures that suit the environment.

Specific Fire Hazards

No further relevant information available.

Firefighter Protection Equipment

Wear self-contained breathing apparatus.

Spill Response

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

Environmental Precautions

Do not allow product to reach sewage system or water bodies.

Cleanup Methods

Collect mechanically.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Physical State
solid
Critical Property
Physical State Data
solid
State Under Standard Conditions
Not available
Appearance
Not available
Colour
Dark red
Colour Intensity
Not available
Form
Powder
Odor
Odourless
Odor Threshold
Not available
Ph
Neutral
Melting Point
Not determined
Critical Property
Boiling Point
Not determined
Critical Property
Flash Point
Not applicable
Critical Property
Freezing Point
Not determined
Softening Point
Not available
Solidification Point
Not available
Cloud Point
Not available
Crystallisation Point
Not available
Relative Evaporation Rate
Not available
Evaporation Rate
Not available
Vapor Pressure
0 hPa
Vapor Density
Not available
Relative Density
Not available
Bulk Density
Not available
Density
Not determined
Critical Property
Flammability
Not available
Upper Explosive Limit
Not available
Lower Explosive Limit
Not available
Explosive Limits
Not available
Auto Ignition Temperature
Product is not selfigniting.
Decomposition Temperature
Not available
Solubility
Unsoluble
Partition Coefficient
Not determined.
Solubility In Water
Unsoluble
Solubility In Fat
Not available
Molecular Weight
Not available
Voc Content
Not available
Metal Corrosion
Void
Dynamic Viscosity
Not applicable.
Kinematic Viscosity
Not applicable.
Properties Status
Not available
Handling & Storage

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

Handling Precautions

Ensure good ventilation/exhaustion at the workplace.

Prevent formation of dust.

Provide suction extractors if dust is formed.

Storage Conditions

No special requirements.

No further information about storage conditions.

Fire Prevention Measures

No special measures required.

Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

The application of this product requires well exhausted firing kilns and efficient ventilation of working areas.

Hand Protection

The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Use gloves of stable material (e.g. Nitrile) - if necessary tricoted to improve the wearability. Material of gloves: Nitrile rubber, NBR. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Penetration time of glove material: The exact breakthrough time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eye Protection

Not required.

Respiratory Protection

Not required.

Section 10

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

Chemical Stability

No decomposition if used according to specifications.

Reactivity

No further relevant information available.

Hazardous Reactions

No dangerous reactions known

Conditions to Avoid

No further relevant information available.

Incompatible Materials

No further relevant information available.

Hazardous Decomposition Products

No dangerous decomposition products known

Section 13

Waste Disposal & Treatment Methods

Waste disposal procedures, treatment methods, and regulatory compliance requirements

Waste Treatment Methods

Must not be disposed of together with household garbage. Do not allow product to reach sewage system.

Product Disposal Recommendations

Must not be disposed of together with household garbage. Do not allow product to reach sewage system.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

Not regulated

Proper Shipping Name

Not regulated

Transport Hazard Class

Not regulated

Packing Group

Not regulated

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for CORE RANGE GLAZE ST.PINK CT1108?

The signal word for this substance is "no signal word".

What is the physical form of CORE RANGE GLAZE ST.PINK CT1108?

CORE RANGE GLAZE ST.PINK CT1108 is a solid with dark red color. It has odourless odor.

What is the solubility of CORE RANGE GLAZE ST.PINK CT1108?

Unsoluble

What is CORE RANGE GLAZE ST.PINK CT1108 used for?

Pigment

What is the melting point of CORE RANGE GLAZE ST.PINK CT1108?

The melting point is Not determined and the boiling point is Not determined.