NextSDS Logo
He

Hempadur Tiecoat 49187 Base

WARNING Liquid. SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Hempadur Tiecoat 49187 Base
Product Form
epoxy paint (base for multi-component product)
Product Code
00138093

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Industrial applications, Professional applications, Used by spraying.

Overview

Hempadur Tiecoat 49187 Base commonly used industrial applications, professional applications, used by spraying..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Flam. Liq. Category 3 H226
Skin Irrit. Category 2 H315
Eye Irrit. Category 2 H319
Skin Sens. Category 1 H317
Aquatic Chronic Category 3 H412

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H226: Flammable liquid and vapor.
  • H315: Causes skin irritation.
  • H317: May cause an allergic skin reaction.
  • H319: Causes serious eye irritation.
  • H412: Harmful to aquatic life with long lasting effects.

Precautionary Statements

  • Wear protective gloves.
  • Keep away from heat, hot surfaces, sparks, open flames and other ignition sources.
  • No smoking.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Hempel (The Netherlands) B.V.

national supplier

πŸ“

Karel Doormanweg 7c 3115 JD Schiedam Nederland

🌍

NL

πŸ“ 

+31 10 4600883

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

πŸ“ž

+31 10 4454000

🌍

NL

πŸ•’

08.00 - 17.00

Nationaal Vergiftigingen Informatie Centrum (NVIC)

πŸ“ž

088 755 8000

🌍

NL

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
acΓ©tate de 2-mΓ©thoxy- 1-mΓ©thylΓ©thyle
EC: 204-658-1
123-86-4 10-14% ⚠️ Hazardous
XYLENE; MELANGE ISOMERES O,M,P
EC: 215-535-7
1330-20-7 5-10% ⚠️ Hazardous
bis-[4-(2,3epoxypropoxy)fenyl]propaan
EC: 216-823-5
1675-54-3 5-10% ⚠️ Hazardous
Solvent naphtha (petroleum), light arom.
EC: 918-668-5
128601-23-0 1-3.6% ⚠️ Hazardous
ethylbenzene
EC: 202-849-4
100-41-4 1-3% ⚠️ Hazardous
butane-1-ol
EC: 200-751-6
71-36-3 1.7% ⚠️ Hazardous
cashew (anacardium occidentale) nutshell extract, decarboxylated, distilled, oligomerisation products with 1-chloro-2,3-epoxypropane
EC: 500-210-7
68413-24-1 1% ⚠️ Hazardous
1,3-bis(12-hydroxyocta- decanamide-N-methyle) benzene
EC: 423-300-7
N/A 1% ⚠️ Hazardous
4-methylpentan-2-one; isobutyl methyl ketone substance with a Community workplace exposure limit
EC: 203-550-1
108-10-1 1% ⚠️ Hazardous

Composition Notes

There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment and hence require reporting in this section.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Remove to fresh air and keep at rest in a position comfortable for breathing. Give nothing by mouth. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. If unconscious, place in recovery position and get medical attention immediately.

Symptoms:

No known significant effects or critical hazards. No specific data for over-exposure signs/symptoms.

πŸ–οΈ Skin Contact

Wash skin thoroughly with soap and water or use recognized skin cleanser. Do NOT use solvents or thinners. Remove contaminated clothing and shoes.

Symptoms:

Causes skin irritation. May cause an allergic skin reaction. Adverse symptoms may include: irritation, redness.

πŸ‘οΈ Eye Contact

Check for and remove any contact lenses. Immediately flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Seek immediate medical attention/advice.

Symptoms:

Causes serious eye irritation. Adverse symptoms may include: pain or irritation, watering, redness.

🍽️ Ingestion/Swallowing

If swallowed, seek medical advice immediately and show this container or label. Keep person warm and at rest. Do not induce vomiting unless directed to do so by medical personnel. Lower the head so that vomit will not re-enter the mouth and throat.

Symptoms:

No known significant effects or critical hazards. No specific data for over-exposure signs/symptoms.

🚨 Immediate Medical Attention Required

In all cases of doubt, or when symptoms persist, seek medical attention. If breathing is irregular, drowsiness, loss of consciousness or cramps: Call 112 and give immediate treatment (first aid). Seek immediate medical attention/advice for eye contact. If unconscious due to inhalation, get medical attention immediately. If swallowed, seek medical advice immediately. Treat symptomatically. Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.

Medical Treatment

Treat symptomatically. Contact poison treatment specialist immediately if large quantities have been ingested or inhaled. No specific treatment.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

πŸ§ͺ Physical State
Liquid.
Critical Property
πŸ“Š Physical State Data
liquid
πŸ“Š State Under Standard Conditions
Not available
πŸ‘οΈ Appearance
Not available
🎨 Colour
Brownish
πŸ“Š Colour Intensity
Not available
πŸ“Š Form
Not available
πŸ‘ƒ Odor
Solvent-like
πŸ“Š Odor Threshold
Not available
πŸ§ͺ Ph
Testing not relevant or not possible due to nature of the product.
🧊 Melting Point
Testing not relevant or not possible due to nature of the product.
Critical Property
πŸ’¨ Boiling Point
Testing not relevant or not possible due to nature of the product.
Critical Property
πŸ”₯ Flash Point
Closed cup: 30 (86F)
Critical Property
πŸ“Š Freezing Point
Testing not relevant or not possible due to nature of the product.
πŸ“Š Softening Point
Not available
πŸ“Š Solidification Point
Not available
πŸ“Š Cloud Point
Not available
πŸ“Š Crystallisation Point
Not available
πŸ“Š Relative Evaporation Rate
Not available
πŸ’¨ Evaporation Rate
Not available.
πŸ’¨ Vapor Pressure
Not available
πŸ“Š Vapor Density
Not available
πŸ“Š Relative Density
1.4 g/cm3
πŸ“Š Bulk Density
Not available
βš–οΈ Density
Not available
πŸ”₯ Flammability
Highly flammable in the presence of the following materials or conditions: open flames, sparks and static discharge and heat.
πŸ“Š Upper Explosive Limit
Not available
πŸ“Š Lower Explosive Limit
Not available
πŸ“Š Explosive Limits
Not available
πŸ“Š Auto Ignition Temperature
Flammable in the presence of the following materials or conditions: oxidizing materials. Not applicable. [50 (122F)]
πŸ“Š Decomposition Temperature
Testing not relevant or not possible due to nature of the product.
πŸ’§ Solubility
Not available
πŸ“Š Partition Coefficient
Testing not relevant or not possible due to nature of the product.
πŸ“Š Solubility In Water
Not available
πŸ“Š Solubility In Fat
Not available
πŸ“Š Molecular Weight
Not available
πŸ“Š Voc Content
418.2 g/l
πŸ“Š Metal Corrosion
Not available
πŸ“Š Dynamic Viscosity
Not available
πŸ“Š Kinematic Viscosity
Not available
πŸ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Arrange sufficient ventilation by local exhaust ventilation and good general ventilation to keep the airborne concentrations of vapors or dust lowest possible and below their respective threshold limit value. Ensure that eyewash stations and safety showers are proximal to the work-station location.

🧀 Hand Protection

Wear chemically resistant gloves (tested to EN374) in combination with 'basic' employee training. The quality of the chemical-resistant protective gloves must be chosen as a function of the specific workplace concentrations and quantity of hazardous substances. Since the actual work situation is unknown. Supplier of gloves should be contacted in order to find the appropriate type. Below listed glove(s) should be regarded as generic advice: Recommended: Silver Shield / Barrier / 4H gloves, polyvinyl alcohol (PVA), Viton May be used: nitrile rubber (>0.3 mm), butyl rubber (>0.5 mm) Short term exposure: neoprene rubber (>0.1 mm), natural rubber (latex) (>0.4 mm), polyvinyl chloride (PVC), nitrile rubber (>0.1 mm), butyl rubber (>0.3 mm)

πŸ‘οΈ Eye Protection

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: chemical splash goggles.

😷 Respiratory Protection

Use a properly fitted, air-purifying or air-fed respirator complying with an approved standard if a risk assessment indicates this is necessary. Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator. If working areas have insufficient ventilation: When the product is applied by means that will not generate an aerosol such as, brush or roller wear half or totally covering mask equipped with gas filter of type A, when grinding use particle filter of type P. (EN140) Be sure to use an approved/certified respirator or equivalent.

🦺 Skin/Body Protection

Personal protective equipment for the body should be selected based on the task being performed and the risks involved handling this product.

🌍 Environmental Exposure Controls

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

🏷️ UN Number

1263

πŸ“¦ Proper Shipping Name

PAINT

πŸ“‹ Packing Group

III

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Hempadur Tiecoat 49187 Base?

The signal word for this substance is "warning".

What is the physical form of Hempadur Tiecoat 49187 Base?

Hempadur Tiecoat 49187 Base is a liquid. with brownish color. It has solvent-like odor.

What is Hempadur Tiecoat 49187 Base used for?

Industrial applications, Professional applications, Used by spraying.

What are the hazard statements for Hempadur Tiecoat 49187 Base?

This substance has 5 hazard statements: H226: Flammable liquid and vapor. H315: Causes skin irritation. H317: May cause an allergic skin reaction. H319: Causes serious eye irritation. H412: Harmful to aquatic life with long lasting effects.

What is the melting point of Hempadur Tiecoat 49187 Base?

The melting point is Testing not relevant or not possible due to nature of the product. and the boiling point is Testing not relevant or not possible due to nature of the product..