Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
Hempadur 15579 Base commonly used consumer applications, industrial applications, professional applications, used by spraying. buildings and metal industry. ships and shipyards..
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS02
GHS07
GHS05
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
- H226: Flammable liquid and vapor.
- H315: Causes skin irritation.
- H317: May cause an allergic skin reaction.
- H318: Causes serious eye damage.
- H332: Harmful if inhaled.
Precautionary Statements
- Keep out of reach of children. If medical advice is needed, have product container or label at hand.
- Wear protective gloves. Wear eye or face protection. Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Use only outdoors or in a well-ventilated area. Avoid breathing vapor. Wash thoroughly after handling.
- IF INHALED: Call a POISON CENTER or doctor if you feel unwell. IF ON SKIN: Wash with plenty of water. If skin irritation or rash occurs: Get medical advice or attention. Take off contaminated clothing and wash it before reuse. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER or doctor.
- Dispose of contents and container in accordance with all local, regional, national and international regulations.
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
Hempel (The Netherlands) B.V.
national supplier
Karel Doormanweg 7c 3115 JD Schiedam Nederland
NL
+31 10 4454000
+31 10 4600883
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
CENTRE ANTIPOISONS
070/245.245
BE
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
MixturesChemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Xyleen (mengsel) EC: 215-535-7 | 1330-20-7 | 10-25% | โ ๏ธ Hazardous |
| middle molecular epoxy resin EC: 500-033-5 | 25068-38-6 | 10-25% | โ ๏ธ Hazardous |
| ethylbenzene EC: 202-849-4 | 100-41-4 | 3-5% | โ ๏ธ Hazardous |
| butaan-1-ol, n-butanol EC: 200-751-6 | 71-36-3 | 3-5% | โ ๏ธ Hazardous |
| n-Butyl acetate EC: 204-658-1 | 123-86-4 | 1-3% | โ ๏ธ Hazardous |
| 1,3-bis(12-hydroxyoctadecanamide-N-methyle) benzene EC: 423-300-7 | N/A | 1% | โ ๏ธ Hazardous |
Composition Notes
There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment and hence require reporting in this section.
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
๐ซ Inhalation Exposure
Remove to fresh air and keep at rest in a position comfortable for breathing. Give nothing by mouth. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. If unconscious, place in recovery position and get medical attention immediately.
๐๏ธ Skin Contact
Wash skin thoroughly with soap and water or use recognized skin cleanser. Do NOT use solvents or thinners. Remove contaminated clothing and shoes.
Symptoms:
Causes skin irritation. May cause an allergic skin reaction. Adverse symptoms may include the following: pain or irritation, redness, blistering may occur.
๐๏ธ Eye Contact
Check for and remove any contact lenses. Immediately flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Seek immediate medical attention/advice.
Symptoms:
Causes serious eye damage. Adverse symptoms may include the following: pain, watering, redness.
๐ฝ๏ธ Ingestion/Swallowing
If swallowed, seek medical advice immediately and show this container or label. Keep person warm and at rest. Do not induce vomiting unless directed to do so by medical personnel. Lower the head so that vomit will not re-enter the mouth and throat.
Symptoms:
No known significant effects or critical hazards. Adverse symptoms may include the following: stomach pains.
๐จ Immediate Medical Attention Required
In all cases of doubt, or when symptoms persist, seek medical attention. If breathing is irregular, drowsiness, loss of consciousness or cramps: Call 112 and give immediate treatment (first aid). Seek immediate medical attention/advice for eye contact. If unconscious (due to inhalation), get medical attention immediately. If swallowed, seek medical advice immediately. Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.
Medical Treatment
Treat symptomatically. No specific treatment.
Fire Fighting Measures & Emergency Response
Fire suppression methods, extinguishing media, and firefighting safety procedures
โ Suitable Extinguishing Media
alcohol resistant foam, CO 2, powders, water spray.
โ Unsuitable Extinguishing Media
waterjet.
โ ๏ธ Specific Fire Hazards
Flammable liquid and vapor. Runoff to sewer may create fire or explosion hazard. In a fire or if heated, a pressure increase will occur and the container may burst, with the risk of a subsequent explosion.
๐ฅ Fire Fighting Instructions
Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training. Fire will produce dense black smoke. Exposure to decomposition products may cause a health hazard. Cool closed containers exposed to fire with water.
๐ก๏ธ Firefighter Protection Equipment
Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.
Accidental Release Measures & Spill Response
Emergency spill cleanup procedures, containment methods, and environmental protection
๐จ Emergency Procedures
Avoid all direct contact with the spilled material. Exclude sources of ignition and be aware of explosion hazard. Ventilate the area. Avoid breathing vapor or mist. Refer to protective measures listed in sections 7 and 8. No action shall be taken involving any personal risk or without suitable training.
๐ Environmental Precautions
Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers. Inform the relevant authorities if the product has caused environmental pollution (sewers, waterways, soil or air).
๐งน Cleanup Methods
Contain and collect spillage with noncombustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations (see Section 13). Use spark-proof tools and explosion-proof equipment.
Cleanup Materials:
noncombustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Safe Handling & Storage Procedures
Industrial handling precautions, storage conditions, and workplace safety requirements
โ ๏ธ Handling Precautions
โข Vapors are heavier than air and may spread along floors.
โข Vapors may form explosive mixtures with air.
โข Prevent the creation of flammable or explosive concentrations of vapors in air and avoid vapor concentrations higher than the occupational exposure limits.
โข In addition, the product should be used only in areas from which all naked lights and other sources of ignition have been excluded.
โข Electrical equipment should be protected to the appropriate standard.
โข To dissipate static electricity during transfer, ground drum and connect to receiving container with bonding strap.
โข No sparking tools should be used.
โข Contains epoxy constituents.
โข Avoid all possible skin contact with epoxy and amine containing products, they may cause allergic reactions.
โข Avoid inhalation of vapour, dust and spray mist.
โข Avoid contact with skin and eyes.
โข Eating, drinking and smoking should be prohibited in area where this material is handled, stored and processed.
โข Appropriate personal protective equipment: see Section 8.
โข Always keep in containers made from the same material as the original one.
๐ช Storage Conditions
โข Store in accordance with local regulations.
โข Store in a cool, well-ventilated area away from incompatible materials and ignition sources.
โข Keep out of the reach of children.
โข Keep away from: Oxidizing agents, strong alkalis, strong acids.
โข No smoking.
โข Prevent unauthorized access.
โข Containers that are opened must be carefully resealed and kept upright to prevent leakage.
๐งผ General Hygiene Measures
Eating, drinking and smoking should be prohibited in area where this material is handled, stored and processed.
๐ฅ Fire Prevention Measures
Prevent the creation of flammable or explosive concentrations of vapors in air and avoid vapor concentrations higher than the occupational exposure limits. In addition, the product should be used only in areas from which all naked lights and other sources of ignition have been excluded.
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
๐ญ Engineering Controls
Arrange sufficient ventilation by local exhaust ventilation and good general ventilation to keep the airborne concentrations of vapors or dust lowest possible and below their respective threshold limit value. Ensure that eyewash stations and safety showers are proximal to the workstation location.
๐งค Hand Protection
Wear chemically resistant gloves (tested to EN374) in combination with 'basic' employee training. The quality of the chemical-resistant protective gloves must be chosen as a function of the specific workplace concentrations and quantity of hazardous substances. Since the actual work situation is unknown. Supplier of gloves should be contacted in order to find the appropriate type. Below listed glove(s) should be regarded as generic advice: May be used: neoprene rubber (>0.1 mm), butyl rubber (>0.5 mm), nitrile rubber (>0.3 mm) Recommended: Silver Shield / Barrier / 4H gloves, Viton, polyvinyl alcohol (PVA) Short term exposure: polyvinyl chloride (PVC), butyl rubber (>0.3 mm), nitrile rubber (>0.1 mm), natural rubber (latex) (>0.4 mm)
๐๏ธ Eye Protection
Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: chemical splash goggles and/or face shield. If inhalation hazards exist, a full-face respirator may be required instead.
๐ท Respiratory Protection
When the product is applied by spraying and for continuous or prolonged work always wear an air-fed respirator e.g. hood with supply of fresh or compressed air or a full face, powered air purifying filter. Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator. If working areas have insufficient ventilation: When the product is applied by means that will not generate an aerosol such as, brush or roller wear half or totally covering mask equipped with gas filter of type A, when grinding use particle filter of type P. (EN140) Be sure to use an approved/certified respirator or equivalent.
๐ฆบ Skin/Body Protection
Personal protective equipment for the body should be selected based on the task being performed and the risks involved handling this product. Wear suitable protective clothing. Always wear protective clothing when spraying. Chemical-resistant apron.
๐ Environmental Exposure Controls
Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.
Chemical Stability & Reactivity Data
Chemical stability, hazardous reactions, and incompatible materials information
โ Chemical Stability
The product is stable.
โ๏ธ Reactivity
No specific test data related to reactivity available for this product or its ingredients.
โ ๏ธ Hazardous Reactions
Under normal conditions of storage and use, hazardous reactions will not occur.
๐ซ Conditions to Avoid
Avoid all possible sources of ignition (spark or flame). Do not pressurize, cut, weld, braze, solder, drill, grind or expose containers to heat or sources of ignition.
๐งช Incompatible Materials
Highly reactive or incompatible with the following materials: oxidizing materials. Reactive or incompatible with the following materials: reducing materials.
๐จ Hazardous Decomposition Products
When exposed to high temperatures (i.e. in case of fire) harmful decomposition products may be formed: Decomposition products may include the following materials: carbon oxides halogenated compounds metal oxide/oxides
Ecological Information & Environmental Impact
Environmental toxicity, biodegradation, bioaccumulation, and ecological effects data
๐ฑ Toxicity
๐ฑ Persistence and degradability
๐ฑ Bioaccumulative potential
๐ฑ Mobility in soil
๐ฑ Results of PBT and vPvB assessment
๐ฑ Endocrine disrupting properties
๐ฑ Other adverse effects
Waste Disposal & Treatment Methods
Waste disposal procedures, treatment methods, and regulatory compliance requirements
โป๏ธ Waste Treatment Methods
The generation of waste should be avoided or minimized wherever possible. Residues of the product is listed as hazardous waste. Dispose of according to all state and local applicable regulations. Waste should not be disposed of untreated to the sewer unless fully compliant with the requirements of all authorities with jurisdiction. Spillage, remains, discarded clothes and similar should be discarded in a fireproof container.
๐๏ธ Product Disposal Recommendations
Dispose of according to all state and local applicable regulations.
๐ท๏ธ Waste Classification Codes
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
๐ท๏ธ UN Number
UN1263
๐ฆ Proper Shipping Name
PAINT
โ ๏ธ Transport Hazard Class
3
๐ Packing Group
III
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for Hempadur 15579 Base?
The signal word for this substance is "danger".
What is the physical form of Hempadur 15579 Base?
Hempadur 15579 Base is a liquid. with brown. color. It has solvent-like odor.
What is Hempadur 15579 Base used for?
Consumer applications, Industrial applications, Professional applications, Used by spraying. buildings and metal industry. ships and shipyards.
What are the hazard statements for Hempadur 15579 Base?
This substance has 5 hazard statements: H226: Flammable liquid and vapor. H315: Causes skin irritation. H317: May cause an allergic skin reaction. H318: Causes serious eye damage. H332: Harmful if inhaled.
What is the melting point of Hempadur 15579 Base?
The melting point is Testing not relevant or not possible due to nature of the product. and the boiling point is Testing not relevant or not possible due to nature of the product..