NextSDS Logo
PH

PHENGUARD 985 BASE OFFWHITE

DANGER Liquid. SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
PHENGUARD 985 BASE OFFWHITE
Product Code
00463846

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Professional applications, Used by spraying. Coating.
Uses Advised Against
Product is not intended, labelled or packaged for consumer use.

Overview

PHENGUARD 985 BASE OFFWHITE is a characteristic. substance commonly used professional applications, used by spraying. coating..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Flam. Liq. Category 3 H226
Skin Irrit. Category 2 H315
Eye Dam. Category 1 H318
Skin Sens. Category 1 H317
Aquatic Chronic Category 3 H412

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS05 GHS Hazard Pictogram: Corrosive hazard - Materials that can cause severe skin burns and eye damage

GHS05

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

  • P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
  • P273: Avoid release to the environment.
  • P280: Wear protective gloves. Wear eye or face protection.
  • P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
  • P310: Immediately call a POISON CENTER or doctor.
  • P501: Dispose of contents and container in accordance with all local, regional, national and international regulations.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Sigma Paint Saudi Arabia Ltd.

undefined

๐Ÿ“

PO Box 7509 Dammam 31472 Saudi Arabia

๐ŸŒ

SA

๐Ÿ“ž

00966 138 47 31 00

๐Ÿ“ 

00966 138 47 17 34

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

00966 138473100 extn 1001

๐ŸŒ

SA

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixture

General Composition

There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment, are PBTs, vPvBs or Substances of equivalent concern, or have been assigned a workplace exposure limit and hence require reporting in this section.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Phenol, polymer with formaldehyde, glycidyl ether (MW<=700)
EC: 215-535-7
28064-14-4 10-25% โš ๏ธ Hazardous
xylene isomers mixture
EC: 905-215-1
1330-20-7 10-15% โš ๏ธ Hazardous
2-METHYL-1-PROPANOL
EC: 201-148-0
78-83-1 1-4.7% โš ๏ธ Hazardous
ETHYLBENZOL
EC: 202-849-4
100-41-4 1-5% โš ๏ธ Hazardous

Composition Notes

This mixture contains 1% of titanium dioxide. The Annex VI classification of titanium dioxide does not apply to this mixture according to Note 10.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Remove to fresh air. Keep person warm and at rest. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel.

Symptoms:

No known significant effects or critical hazards. No specific data.

๐Ÿ–๏ธ Skin Contact

Remove contaminated clothing and shoes. Wash skin thoroughly with soap and water or use recognised skin cleanser.

Symptoms:

Causes skin irritation. Defatting to the skin. May cause an allergic skin reaction. Adverse symptoms may include the following: pain or irritation, redness, dryness, cracking, blistering may occur.

๐Ÿ‘๏ธ Eye Contact

Check for and remove any contact lenses. Immediately flush eyes with running water for at least 15 minutes, keeping eyelids open.

Symptoms:

Causes serious eye damage. Adverse symptoms may include the following: pain, watering, redness.

๐Ÿฝ๏ธ Ingestion/Swallowing

If swallowed, seek medical advice immediately and show the container or label. Keep person warm and at rest. Do NOT induce vomiting.

Symptoms:

No known significant effects or critical hazards. Adverse symptoms may include the following: stomach pains.

๐Ÿšจ Immediate Medical Attention Required

Seek immediate medical attention. If swallowed, seek medical advice immediately and show the container or label. Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.

Medical Treatment

Treat symptomatically. No specific treatment.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid.
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Characteristic.
๐ŸŽจ Colour
Not available.
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Characteristic.
๐Ÿ“Š Odor Threshold
Not available.
๐Ÿงช Ph
Not available.
๐ŸงŠ Melting Point
Not available.
Critical Property
๐Ÿ’จ Boiling Point
>37.78C
Critical Property
๐Ÿ”ฅ Flash Point
26C
Critical Property
๐Ÿ“Š Freezing Point
-94.9C (-138.8F)
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
-94.9C (-138.8F)
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available.
๐Ÿ’จ Vapor Pressure
<12.00102 mm Hg, <1.6 kPa (at 20C)
๐Ÿ“Š Vapor Density
3.46 (Air = 1)
๐Ÿ“Š Relative Density
0.75compared with butyl acetate
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
Not applicable.
๐Ÿ“Š Upper Explosive Limit
10.9%
๐Ÿ“Š Lower Explosive Limit
1.7%
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
415C (779F)
๐Ÿ“Š Decomposition Temperature
Stable under recommended storage and handling conditions (see Section 7).
๐Ÿ’ง Solubility
Not applicable. insoluble in water.
๐Ÿ“Š Partition Coefficient
Not applicable.
๐Ÿ“Š Solubility In Water
insoluble in water. (cold water: Not soluble)
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
>21 mm2/s
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapour or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.

๐Ÿงค Hand Protection

butyl rubber Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated. When prolonged or frequently repeated contact may occur, a glove with a protection class of 6 (breakthrough time greater than 480 minutes according to EN 374) is recommended. When only brief contact is expected, a glove with a protection class of 2 or higher (breakthrough time greater than 30 minutes according to EN 374) is recommended. The user must check that the final choice of type of glove selected for handling this product is the most appropriate and takes into account the particular conditions of use, as included in the user's risk assessment.

๐Ÿ‘๏ธ Eye Protection

Chemical splash goggles and face shield.

๐Ÿฆบ Skin/Body Protection

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. When there is a risk of ignition from static electricity, wear anti-static protective clothing. For the greatest protection from static discharges, clothing should include anti-static overalls, boots and gloves. Refer to European Standard EN 1149 for further information on material and design requirements and test methods. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

๐ŸŒ Environmental Exposure Controls

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

UN1263

๐Ÿ“ฆ Proper Shipping Name

PAINT

โš ๏ธ Transport Hazard Class

3

๐Ÿ“‹ Packing Group

III

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for PHENGUARD 985 BASE OFFWHITE?

The signal word for this substance is "danger".

What is the physical form of PHENGUARD 985 BASE OFFWHITE?

PHENGUARD 985 BASE OFFWHITE is a liquid. appearing as characteristic. with not available. color. It has characteristic. odor.

What is the solubility of PHENGUARD 985 BASE OFFWHITE?

Not applicable. insoluble in water.

What is PHENGUARD 985 BASE OFFWHITE used for?

Professional applications, Used by spraying. Coating.

What is the melting point of PHENGUARD 985 BASE OFFWHITE?

The melting point is Not available. and the boiling point is >37.78C.