NextSDS Logo
EC

ECO Interior 10

NO SIGNAL WORD liquide SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
ECO Interior 10
Product Code
293501_281176_294501_ECO

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Nettoyant intérieurs pour usage professionnel (AISE_SUMI_PW_8a_2; AISE_SUMI_PW_10_1; AISE_SUMI_PW_11_1; AISE_SUMI_PW_19_1)

Overview

ECO Interior 10 commonly used nettoyant intérieurs pour usage professionnel (aise_sumi_pw_8a_2; aise_sumi_pw_10_1; aise_sumi_pw_11_1; aise_sumi_pw_19_1).

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Greenspeed company logo - Safety Data Sheet supplier organization

Greenspeed

manufacturer

📍

P.O.Box 1250, 2280 CG Rijswijk (ZH), NL

🌍

NL

📞

+31703458737

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

📞

+32 70 245 245

🌍

BE

Nationaal Vergiftigingen Informatie Centrum (NVIC)

📞

+31 88 755 8000

🌍

NL

🕒

Uitsluitend bestemd om professionele hulpverleners te informeren bij acute vergiftigingen.

Emergency Contact

📞

+ 33 (0)1 45 42 59 59

🌍

FR

Emergency Contact

📞

(+352) 8002-5500

🌍

LU

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Sodium Laureth Sulfate
EC: 500-234-8
68891-38-3 4% ✓ Non-hazardous
3-Butoxypropane-2-ol
EC: 225-878-4
5131-66-8 2% ✓ Non-hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

en cas d'inconfort sévère ou persistant : déplacer à l'air frais et consulter un médecin

Symptoms:

aucun

🖐️ Skin Contact

rincer à l'eau.

Symptoms:

aucun

👁️ Eye Contact

rincer d'abord avec beaucoup d'eau puis consulter un médecin si nécessaire.

Symptoms:

rougeur

🍽️ Ingestion/Swallowing

rincer d'abord avec beaucoup d'eau, consulter un médecin si nécessaire.

Symptoms:

diarrhée, céphalée, crampes abdominales, somnolence, vomissements

🚨 Immediate Medical Attention Required

aucun

Medical Treatment

aucun

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

📊 Odor Threshold
Not available
📊 Colour Intensity
Not available
🧊 Melting Point
0 ℃
Critical Property
📊 State Under Standard Conditions
Not available
🧪 Ph
10,5
📊 Properties Status
Not available
💨 Evaporation Rate
2,000
📊 Cloud Point
Not available
📊 Lower Explosive Limit
1,100 %
📊 Relative Density
1,0130 kg/l
📊 Metal Corrosion
Not available
📊 Dynamic Viscosity
1 mPa.s
⚖️ Density
Not available
💧 Solubility
complètement soluble
🧪 Physical State
liquide
Critical Property
👁️ Appearance
Not available
📊 Explosive Limits
Not available
📊 Partition Coefficient
sans objet
📊 Relative Evaporation Rate
Not available
🎨 Colour
bleu
📊 Freezing Point
Not available
📊 Physical State Data
liquid
📊 Crystallisation Point
Not available
📊 Solubility In Water
complètement soluble
💨 Boiling Point
100 °C - 199 ℃
Critical Property
📊 Molecular Weight
Not available
📊 Voc Content
4,00 %
💨 Vapor Pressure
2 332 Pa
📊 Vapor Density
Not available
👃 Odor
caractéristique
📊 Decomposition Temperature
Not available
📊 Solidification Point
Not available
📊 Auto Ignition Temperature
207 ℃
📊 Softening Point
Not available
📊 Bulk Density
Not available
📊 Upper Explosive Limit
8,700 %
🔥 Flash Point
Not available
🔥 Flammability
sans objet
📊 Kinematic Viscosity
1 mm2/s
📊 Solubility In Fat
Not available
📊 Form
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Le niveau de protection et les types de contrôles nécessaires varient en fonction des conditions d'exposition potentielles. Une ventilation adéquate doit être assurée afin que les limites d'exposition ne soient pas dépassées. Pour plus d'informations, consulter la section 7.

🧤 Hand Protection

manipuler avec des gants en nitrile (EN 374). Délai de rupture > 480' Épaisseur 0,35 mm. Contrôler les gants minutieusement avant l'usage. Retirer les gants convenablement, sans toucher l'extérieur avec les mains nues. Le caractère approprié pour un poste de travail spécifique doit faire l'objet d'une concertation avec le fabricant des gants de protection. Laver et sécher vos mains.

👁️ Eye Protection

garder un flacon d'eau pour bains oculaires à portée de main. Lunettes de protection bien ajustées. Si de très importantes quantités de produit sont utilisées, porter un masque et une combinaison de protection.

😷 Respiratory Protection

pas besoin de moyens de protection respiratoire. En cas d'exposition nocive, utilisez des masques antigaz du type ABEK. A utiliser éventuellement avec une ventilation d'extraction suffissante.

🦺 Skin/Body Protection

vêtements imperméables. Le type d'équipement de protection dépend de la concentration et de la quantité de substances dangereuses sur le poste de travail en question.

🌍 Environmental Exposure Controls

Se conformer aux réglementations environnementales applicables limitant les rejets dans l'air, l'eau et le sol. Protéger l'environnement en appliquant des mesures de contrôle appropriées afin de prévenir ou de limiter les émissions. Pour plus d'informations, consulter les sections 6 et 13.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for ECO Interior 10?

The signal word for this substance is "no signal word".

What is the physical form of ECO Interior 10?

ECO Interior 10 is a liquide with bleu color. It has caractéristique odor.

What is the solubility of ECO Interior 10?

complètement soluble

What is ECO Interior 10 used for?

Nettoyant intérieurs pour usage professionnel (AISE_SUMI_PW_8a_2; AISE_SUMI_PW_10_1; AISE_SUMI_PW_11_1; AISE_SUMI_PW_19_1)

What is the melting point of ECO Interior 10?

The melting point is 0 ℃ and the boiling point is 100 °C - 199 ℃.