Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- UHU repair all powerkitt
- Product Code
- GRF EPOXY REPAIR STICK DP 114G*12 L41
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Colle
Manufacturers & Suppliers
UHU GmbH & Co.KG
manufacturer
Herrmannstrae 7 D-77815 Bhl (Baden)
0049-(0)7223-284-0
Bison International
Excelsiorlaan 27, B 3 B-1930 Zaventem
+32 3 710 92 92
Emergency Contacts
Centre Antipoisons
070 245245
Emergency Contact
8002 - 5500
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Colle
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| reaction product: bisphenol A- (epichlorhydrin); epoxy resin (number average molecular weight <700) EC: 500-033-5 | 25068-38-6 | 10 - 25% | Yes |
| 2,4,6-tris(diméthylaminométhyl)phénol EC: 202-013-9 | 90-72-2 | 1 - 2.5% | Yes |
Pour le libellé des phrases de risque citées, se référer au chapitre 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
Donner de l'air frais en abondance et consulter un mdecin pour plus de scurit. En cas d'inconscience, coucher et transporter la personne en position latrale stable.
Laver immdiatement l'eau et au savon et bien rincer.
Rincer les yeux, pendant plusieurs minutes, sous l'eau courante en cartant bien les paupires. Si les troubles persistent, consulter un mdecin.
Si les troubles persistent, consulter un mdecin.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The data for this section has not been processed yet.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
The data for this section has not been processed yet.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
The data for this section has not been processed yet.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Gants de protection Le matriau des gants doit tre impermable et rsistant au produit / la substance / la prparation. Choix du matriau des gants en fonction des temps de pntration, du taux de permabilit et de la dgradation. Matriau des gants : butyl-rubber (e.g. Butoject 898: material thickness 0,7 mm), Break through time : > 8 h Material : Ethyl Vinyl Alcohol Laminate (EVAL), Break through time : > 8 h glove material for short-term use / splash: (10 min <BTT <480 min): nitrile rubber, neoprene rubber The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it. Gloves should be discarded and replaced if there is any indication of degradation or chemical breakthrough. Take note of the information given by the producer concerning permeability and break through times, and of special workplace conditions (mechanical strain, duration of contact). The suitability for a specific workplace should be discussed with the producers of the protective gloves. Temps de pntration du matriau des gants : Le temps de pntration exact est dterminer par le fabricant des gants de protection et respecter.
Lunettes de protection hermtiques Lunettes de protection recommandes pour le transvasement.
N'est pas ncessaire.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The data for this section has not been processed yet.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for UHU repair all powerkitt?
The signal word is warning.
What is the physical form of UHU repair all powerkitt?
UHU repair all powerkitt is a liquide with selon dsignation produit color. It has caractristique odor.
What is UHU repair all powerkitt used for?
Colle
What are the hazard statements for UHU repair all powerkitt?
This substance has 4 hazard statements:
- H315: Provoque une irritation cutane.
- H317: Peut provoquer une allergie cutane.
- H319: Provoque une svre irritation des yeux.
- H412: Nocif pour les organismes aquatiques, entrane des effets nfastes long terme.
What is the melting point of UHU repair all powerkitt?
The melting point is Non dtermin. and the boiling point is Non dtermin..