NextSDS Logo
Fi

Fix ALL Turbo

NO SIGNAL WORD Solide SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Fix ALL Turbo
Product Form
Mlange

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Mastics
Uses Advised Against
Pas dinformations complmentaires disponibles

Overview

Fix ALL Turbo is a pteux. substance commonly used mastics.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

Hazard Classifications

Not Classified

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Soudal N.V. company logo - Safety Data Sheet supplier organization

Soudal N.V.

undefined

πŸ“

Everdongenlaan 18-20 2300 Turnhout Belgium

🌍

BE

πŸ“ž

+32 14 42 42 31

πŸ“ 

+32 14 42 65 14

🌐 www.Soudal.com

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

ORFILA

πŸ“ž

+33 1 45 42 59 59

🌍

FR

πŸ•’

24 heures sur 24 et 7 jours sur 7

πŸ’‘

Ce numro permet dobtenir les coordonnes de tous les centres Anti poison Franais. Ces centres anti-poison et de toxicovigilance fournissent une aide mdicale gratuite (hors cot dappel), 24 heures sur 24 et 7 jours sur 7.

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Trimethoxyvinylsilane
EC: 220-449-8
2768-02-7 Not specified ⚠️ Hazardous
hydrocarbons, C13-C23, n-alkanes, isoalkanes, cyclics, <0.03% aromatics
EC: 932-078-5
N/A 29% ⚠️ Hazardous
3-(trimthoxysilyl)propylamine
EC: 237-511-5
13822-56-5 45% ⚠️ Hazardous

Additional Information

Texte intgral des mentions H et EUH : voir rubrique 16

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Transporter la personne lextrieur et la maintenir dans une position o elle peut confortablement respirer.

Symptoms:

Troubles respiratoires

πŸ–οΈ Skin Contact

Rincer la peau leau/se doucher.

Symptoms:

irritation ou druption cutane

πŸ‘οΈ Eye Contact

Rincer les yeux leau par mesure de prcaution. Enlever les lentilles de contact si la victime en porte et si elles peuvent tre facilement enleves. Continuer rincer.

Symptoms:

irritation

🍽️ Ingestion/Swallowing

Rincer la bouche leau.

Symptoms:

malaise

🚨 Immediate Medical Attention Required

En cas de malaise consulter un mdecin. Troubles respiratoires: consulter un mdecin/service mdical. En cas d'irritation ou d'ruption cutane: consulter un mdecin. Consulter un ophtalmologue si l'irritation persiste.

Medical Treatment

Traitement symptomatique.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

πŸ§ͺ Physical State
Solide
Critical Property
πŸ“Š Physical State Data
solid
πŸ“Š State Under Standard Conditions
Not available
πŸ‘οΈ Appearance
Pteux.
🎨 Colour
Variable.
πŸ“Š Colour Intensity
Not available
πŸ“Š Form
Not available
πŸ‘ƒ Odor
caractristique.
πŸ“Š Odor Threshold
Pas disponible
πŸ§ͺ Ph
Pas disponible
🧊 Melting Point
Non applicable
Critical Property
πŸ’¨ Boiling Point
Pas disponible
Critical Property
πŸ”₯ Flash Point
- 100 C
Critical Property
πŸ“Š Freezing Point
Pas disponible
πŸ“Š Softening Point
Not available
πŸ“Š Solidification Point
Not available
πŸ“Š Cloud Point
Not available
πŸ“Š Crystallisation Point
Not available
πŸ“Š Relative Evaporation Rate
Not available
πŸ’¨ Evaporation Rate
Not available
πŸ’¨ Vapor Pressure
Pas disponible
πŸ“Š Vapor Density
Not available
πŸ“Š Relative Density
1,505 (20C)
πŸ“Š Bulk Density
Not available
βš–οΈ Density
1,505 g/cm (20C)
Critical Property
πŸ”₯ Flammability
Non applicable
πŸ“Š Upper Explosive Limit
Non applicable
πŸ“Š Lower Explosive Limit
Non applicable
πŸ“Š Explosive Limits
Not available
πŸ“Š Auto Ignition Temperature
Non applicable
πŸ“Š Decomposition Temperature
Pas disponible
πŸ’§ Solubility
Pas disponible
πŸ“Š Partition Coefficient
Pas disponible
πŸ“Š Solubility In Water
Not available
πŸ“Š Solubility In Fat
Not available
πŸ“Š Molecular Weight
Not available
πŸ“Š Voc Content
< 1 %
πŸ“Š Metal Corrosion
Not available
πŸ“Š Dynamic Viscosity
Not available
πŸ“Š Kinematic Viscosity
Non applicable
πŸ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Assurer une bonne ventilation du poste de travail.

🧀 Hand Protection

Gants de protection

πŸ‘οΈ Eye Protection

Lunettes de scurit

😷 Respiratory Protection

En cas de ventilation insuffisante, porter un appareil respiratoire appropri

🦺 Skin/Body Protection

Porter un vtement de protection appropri

🌍 Environmental Exposure Controls

viter le rejet dans lenvironnement.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Fix ALL Turbo?

The signal word for this substance is "no signal word".

What is the physical form of Fix ALL Turbo?

Fix ALL Turbo is a solide appearing as pteux. with variable. color. It has caractristique. odor.

What is the solubility of Fix ALL Turbo?

Pas disponible

What is Fix ALL Turbo used for?

Mastics

What is the melting point of Fix ALL Turbo?

The melting point is Non applicable and the boiling point is Pas disponible.