NextSDS Logo
MO

MOUSSE PU EXPANSIVE RÉSISTANTE AU FEU MANUELLE 750 ML ROUGE CLAIR

DANGER Liquide Fluide. Aérosol. SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
MOUSSE PU EXPANSIVE RÉSISTANTE AU FEU MANUELLE 750 ML ROUGE CLAIR
Product Code
BIZ 710 580

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

UFI Code
DQV2-70W4-C00E-EUUP

Unique Formula Identifier - for poison centres and emergency response

Uses Information

Identified Uses
Utilisations identifiées pertinentes de la substance ou du mélange
Uses Advised Against
utilisations déconseillées

Overview

MOUSSE PU EXPANSIVE RÉSISTANTE AU FEU MANUELLE 750 ML ROUGE CLAIR commonly used utilisations identifiées pertinentes de la substance ou du mélange.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (DANGER)

Hazard Classifications

Aerosol Category 1 H222
Skin Irrit. Category 2 H315
Eye Irrit. Category 2 H319
Resp. Sens. Category 1 H334
Skin Sens. Category 1 H317
Carc. Category 2 H351
STOT SE Category 3 H335
STOT RE Category 2 H373

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H222: Aérosol extrêmement inflammable.
  • H229: Récipient sous pression: peut éclater sous l’effet de la chaleur.
  • H315: Provoque une irritation cutanée.
  • H317: Peut provoquer une allergie cutanée.
  • H319: Provoque une sévère irritation des yeux.
  • H334: Peut provoquer des symptômes allergiques ou d'asthme ou des difficultés respiratoires par inhalation.
  • H335: Peut irriter les voies respiratoires.
  • H351: Susceptible de provoquer le cancer (par inhalation).
  • H373: Risque présumé d'effets graves pour les organes à la suite d'expositions répétées ou d'une exposition prolongée .

Precautionary Statements

  • P101: En cas de consultation d’un médecin, garder à disposition le récipient ou l’étiquette.
  • P102: Tenir hors de portée des enfants.
  • P210: Tenir à l'écart de la chaleur, des surfaces chaudes, des étincelles, des flammes nues et de toute autre source d'inflammation. Ne pas fumer.
  • P211: Ne pas vaporiser sur une flamme nue ou sur toute autre source d’ignition.
  • P251: Ne pas perforer, ni brûler, même après usage.
  • P271: Utiliser seulement en plein air ou dans un endroit bien ventilé.
  • P280: Porter des gants de protection/des vêtements de protection/un équipement de protection des yeux/du visage/une protection auditive/ ...
  • P304 + P340: EN CAS D’INHALATION: transporter la personne à l’extérieur et la maintenir dans une position où elle peut confortablement respirer.
  • P305 + P351 + P338: EN CAS DE CONTACT AVEC LES YEUX: Rincer avec précaution à l'eau pendant plusieurs minutes. Enlever les lentilles de contact si la victime en porte et si elles peuvent être facilement enlevées. Continuer à rincer.
  • P410 + P412: Protéger du rayonnement solaire. Ne pas exposer à une température supérieure à 50 oC/122 oF.
  • P501: Éliminer le contenu/récipient dans ...

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

BIZLINE SAS. company logo - Safety Data Sheet supplier organization

BIZLINE SAS.

national supplier

📍

13 boulevard du Fort de Vaux.75017.PARIS.FRANCE.

🌍

FR

📞

+33 (0)1 42 85 85 00

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

📞

112

ORFILA (INRS)

📞

+ 33 (0)1 45 42 59 59

🌍

FR

Tox Info Suisse

📞

145

🌍

CH

Emergency Contact

📞

+32022649636

🌍

BE

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
4,4´-METHYLENEDIPHENYL DIISOCYANATE, ISOMERS AND HOMOLOGUES
EC: 618-498-9
9016-87-9 25-50% ⚠️ Hazardous
POLYETHERPOLYOL HALOGENE 86675-46-9 10-25% ⚠️ Hazardous
BUTANE
EC: 203-448-7
106-97-8 2.5-10% ⚠️ Hazardous
PROPANE
EC: 200-827-9
74-98-6 2.5-10% ⚠️ Hazardous
DIMETHYL ETHER
EC: 204-065-8
115-10-6 2.5-10% ⚠️ Hazardous
PHOSPHATE DE TRIETHYLE
EC: 201-114-5
78-40-0 2.5% ⚠️ Hazardous

Composition Notes

Texte complet des phrases H: voir la rubrique 16

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

En cas d'inhalation massive, transporter le patient à l’air libre, le garder au chaud et au repos. Si la personne est inconsciente, la placer en position latérale de sécurité. Avertir un médecin dans tous les cas pour juger de l’opportunité d’une surveillance et d’un traitement symptomatique en milieu hospitalier. Si la respiration est irrégulière ou arrêtée, pratiquer la respiration artificielle et faire appel à un médecin. En cas de manifestation allergique, consulter un médecin.

Symptoms:

respiration irrégulière ou arrêtée, manifestation allergique

🖐️ Skin Contact

Enlever les vêtements imprégnés et laver soigneusement la peau avec de l'eau et du savon ou utiliser un nettoyant connu. Prendre garde au produit pouvant subsister entre la peau et les vêtements, la montre, les chaussures, ... En cas de manifestation allergique, consulter un médecin. Lorsque la zone contaminée est étendue et/ou s'il apparaît des lésions cutanées, il est nécessaire de consulter un médecin ou de faire transférer en milieu hospitalier.

Symptoms:

manifestation allergique, lésions cutanées

👁️ Eye Contact

Laver abondamment avec de l'eau douce et propre durant 15 minutes en maintenant les paupières écartées. S'il apparaît une douleur, une rougeur ou une gêne visuelle, consulter un ophtalmologiste.

Symptoms:

douleur, rougeur ou gêne visuelle

🍽️ Ingestion/Swallowing

Ne rien faire absorber par la bouche. En cas d'ingestion, si la quantité est peu importante, (pas plus d'une gorgée), rincer la bouche avec de l'eau et consulter un médecin. Faire immédiatement appel à un médecin et lui montrer l'étiquette.

🚨 Immediate Medical Attention Required

En cas de doute ou si des symptômes persistent, toujours faire appel à un médecin. Avertir un médecin dans tous les cas pour juger de l’opportunité d’une surveillance et d’un traitement symptomatique en milieu hospitalier. Si la respiration est irrégulière ou arrêtée, faire appel à un médecin. En cas de manifestation allergique, consulter un médecin. S'il apparaît une douleur, une rougeur ou une gêne visuelle, consulter un ophtalmologiste. Lorsque la zone contaminée est étendue et/ou s'il apparaît des lésions cutanées, il est nécessaire de consulter un médecin ou de faire transférer en milieu hospitalier. Faire immédiatement appel à un médecin et lui montrer l'étiquette.

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

Suitable Extinguishing Media

Les poudres chimiques, le dioxyde de carbone et les autres gaz extincteurs conviennent pour de petits feux.

⚠️ Specific Fire Hazards

Un incendie produira souvent une épaisse fumée noire. L'exposition aux produits de décomposition peut comporter des risques pour la santé. Ne pas respirer les fumées.

🔥 Fire Fighting Instructions

Refroidir les emballages à proximité des flammes pour éviter les risques d'éclatement des récipients sous pression.

🛡️ Firefighter Protection Equipment

Les intervenants seront équipés d'appareils de protection respiratoire autonomes isolants.

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

🚨 Emergency Procedures

Pour les non-secouristes Eviter d'inhaler les vapeurs. Eviter tout contact avec la peau et les yeux. Si les quantités répandues sont importantes, évacuer le personnel en ne faisant intervenir que des opérateurs entraînés munis d'équipements de protection.

🌊 Large Spill Procedures

Si les quantités répandues sont importantes, évacuer le personnel en ne faisant intervenir que des opérateurs entraînés munis d'équipements de protection.

🌍 Environmental Precautions

Empêcher toute pénétration dans les égouts ou cours d'eau.

🧹 Cleanup Methods

Nettoyer de préférence avec un détergent, éviter l'utilisation de solvants. Les surfaces contaminées doivent être très rapidement nettoyées.

Cleanup Materials:

détergent, eau (45 parties, éthanol ou isopropanol (50 parties), ammoniaque concentré (d=0.880)(5 parties), carbonates de sodium (5 parties), eau (95 parties)

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

📊 Lower Explosive Limit
Non précisé.
🧪 Physical State
Liquide Fluide. Aérosol.
Critical Property
🧊 Melting Point
Non concerné.
Critical Property
📊 Bulk Density
Not available
👃 Odor
Not available
📊 Partition Coefficient
Non précisé.
📊 Vapor Density
Not available
📊 Freezing Point
Non précisé.
📊 Cloud Point
Not available
📊 Solubility In Fat
Non précisé.
📊 Decomposition Temperature
Non concerné.
📊 Upper Explosive Limit
Non précisé.
📊 Relative Density
Not available
💨 Boiling Point
Non concerné.
Critical Property
📊 Molecular Weight
Not available
📊 Auto Ignition Temperature
460 °C
👁️ Appearance
Not available
💨 Vapor Pressure
Inférieure à 110 kPa (1.10 bar).
📊 Solubility In Water
Insoluble.
📊 Metal Corrosion
Not available
🔥 Flammability
Non précisé.
📊 Form
Not available
📊 Kinematic Viscosity
Non précisé.
🔥 Flash Point
Non concerné.
Critical Property
📊 Dynamic Viscosity
Not available
📊 Explosive Limits
Not available
⚖️ Density
1,053
Critical Property
📊 Relative Evaporation Rate
Not available
💨 Evaporation Rate
Not available
📊 Crystallisation Point
Not available
📊 Voc Content
Not available
💧 Solubility
Not available
📊 State Under Standard Conditions
Not available
📊 Properties Status
Not available
📊 Solidification Point
Not available
🎨 Colour
Non précisé
📊 Softening Point
Not available
🧪 Ph
Non concerné.
📊 Odor Threshold
Non précisé.
📊 Colour Intensity
Not available
📊 Physical State Data
aerosol

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

⚠️ Handling Precautions

• Les prescriptions relatives aux locaux de stockage sont applicables aux ateliers où est manipulé le mélange.

• Les personnes qui ont des antécédents d'asthme, allergies, des difficultés respiratoires chroniques ou périodiques ne doivent en aucun cas mettre en oeuvre ces mélanges.

• Les personnes qui ont des antécédents de sensibilisation cutanée ne doivent en aucun cas manipuler ce mélange.

• Observer les précautions indiquées sur l'étiquette ainsi que les réglementations de la protection du travail.

• Ne pas respirer les aérosols.

• Eviter l'inhalation des vapeurs.

• Eviter le contact du mélange avec la peau et les yeux.

• Eviter l'exposition - se procurer les instructions spéciales avant utilisation.

🏪 Storage Conditions

• Conserver hors de la portée des enfants.

• Conserver le récipient bien fermé, dans un endroit sec et bien ventilé.

• Conserver à l'écart de toute source d'ignition - Ne pas fumer.

• Tenir éloigné de toute source d'ignition, de chaleur et de la lumière solaire directe.

• Récipient sous pression.

• A protéger contre les rayons solaires et à ne pas exposer à une température supérieure à 50°C.

🧼 General Hygiene Measures

Se laver les mains après chaque utilisation. Enlever et laver les vêtements contaminés avant réutilisation. Il est interdit de fumer, manger et boire dans les locaux où le mélange est utilisé.

🔥 Fire Prevention Measures

Manipuler dans des zones bien ventilées. Empêcher la création de concentrations inflammables ou explosives dans l'air et éviter les concentrations de vapeurs supérieures aux valeurs limites d'exposition professionnelle. Ne pas vaporiser vers une flamme ou un corps incandescent. Ne pas percer ou brûler même après usage. Utiliser le mélange dans des locaux dépourvus de toute flamme nue ou autres sources d'ignition, et posséder un équipement électrique protégé. Garder les emballages solidement fermés et les éloigner des sources de chaleur, d'étincelles et de flammes nues. Ne pas utiliser des outils pouvant provoquer des étincelles. Ne pas fumer. Interdire l'accès aux personnes non autorisées.

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Assurer une ventilation adéquate, surtout dans les endroits clos.

🧤 Hand Protection

Utiliser des gants de protection appropriés résistants aux agents chimiques conformes à la norme EN ISO 374-1. La sélection des gants doit être faite en fonction de l'application et de la durée d'utilisation au poste de travail. Les gants de protection doivent être choisis en fonction du poste de travail : autres produits chimiques pouvant être manipulés, protections physiques nécessaires (coupure, piqûre, protection thermique), dextérité demandée. Type de gants conseillés : - Caoutchouc Nitrile (Copolymère butadiène-acrylonitrile (NBR)) Caractéristiques recommandées : - Gants antistatiques conformes à la norme NF EN16350

👁️ Eye Protection

Eviter le contact avec les yeux. Utiliser des protections oculaires conçues contre les projections de liquide. Avant toute manipulation, il est nécessaire de porter des lunettes à protection latérale conformes à la norme NF EN166. En cas de danger accru, utiliser un écran facial pour la protection du visage. Le port de lunettes correctrices ne constitue pas une protection. Il est recommandé aux porteurs de lentilles de contact d'utiliser des verres correcteurs lors des travaux où ils peuvent être exposés à des vapeurs irritantes. Prévoir des fontaines oculaires dans les ateliers où le produit est manipulé de façon constante.

😷 Respiratory Protection

Eviter l'inhalation des vapeurs. En cas de ventilation insuffisante, porter un appareil respiratoire approprié. Lorsque les travailleurs sont confrontés à des concentrations supérieures aux limites d'exposition, ils doivent porter un appareil de protection respiratoire appropriés et agréés. Type de masque FFP : Porter un demi-masque filtrant contre les aérosols à usage unique conforme à la norme NF EN149/A1. Classe : - FFP1 Filtre(s) anti-gaz et vapeurs (Filtres combinés) conforme(s) à la norme NF EN14387/A1 : - A1 (Marron) Filtre à particules conforme à la norme NF EN143/A1 : - P1 (Blanc)

🦺 Skin/Body Protection

Eviter le contact avec la peau. Porter des vêtements de protection appropriés. Type de vêtement de protection approprié : En cas de fortes projections, porter des vêtements de protection chimique étanches aux liquides (type 3) conformes à la norme NF EN14605/A1 pour éviter tout contact avec la peau. En cas de risque d'éclaboussures, porter des vêtements de protection chimique (type 6) conformes à la norme NF EN13034/A1 pour éviter tout contact avec la peau. Le personnel portera un vêtement de travail régulièrement lavé. Après contact avec le produit, toutes les parties du corps souillées devront être lavées.

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

Chemical Stability

Ce mélange est stable aux conditions de manipulation et de stockage recommandées dans la rubrique 7.

⚗️ Reactivity

Tenir à l'écart d'agents oxydants et de matières fortement acides ou basiques afin d'éviter des réactions exothermiques.

⚠️ Hazardous Reactions

Exposé à des températures élevées, le mélange peut dégager des produits de décomposition dangereux, tels que monoxyde et dioxyde de carbone, fumées, oxyde d'azote. Le mélange peut également dégager du cyanure d'hydrogène, des amines et alcools.

🚫 Conditions to Avoid

Tout appareil susceptible de produire une flamme ou de porter à haute température une surface métallique (brûleurs, arcs électriques, fours...) sera banni des locaux. Eviter : - l'échauffement - la chaleur

🧪 Incompatible Materials

Aucune donnée n'est disponible.

💨 Hazardous Decomposition Products

La décomposition thermique peut dégager/former : - monoxyde de carbone (CO) - dioxyde de carbone (CO2)

Waste Disposal & Treatment Methods

Waste disposal procedures, treatment methods, and regulatory compliance requirements

♻️ Waste Treatment Methods

Ne pas déverser dans les égouts ni dans les cours d'eau. Recycler ou éliminer conformément aux législations en vigueur, par un collecteur ou une entreprise agréée. Ne pas contaminer le sol ou l'eau avec des déchets, ne pas procéder à leur élimination dans l'environnement.

🗂️ Product Disposal Recommendations

La gestion des déchets se fait sans mettre en danger la santé humaine et sans nuire à l'environnement, et notamment sans créer de risque pour l'eau, l'air, le sol, la faune ou la flore. Recycler ou éliminer conformément aux législations en vigueur, par un collecteur ou une entreprise agréée.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

🏷️ UN Number

1950

📦 Proper Shipping Name

AÉROSOLS inflammables

⚠️ Transport Hazard Class

2.1

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for MOUSSE PU EXPANSIVE RÉSISTANTE AU FEU MANUELLE 750 ML ROUGE CLAIR?

The signal word for this substance is "danger".

What is the physical form of MOUSSE PU EXPANSIVE RÉSISTANTE AU FEU MANUELLE 750 ML ROUGE CLAIR?

MOUSSE PU EXPANSIVE RÉSISTANTE AU FEU MANUELLE 750 ML ROUGE CLAIR is a liquide fluide. aérosol. with non précisé color.

What is MOUSSE PU EXPANSIVE RÉSISTANTE AU FEU MANUELLE 750 ML ROUGE CLAIR used for?

Utilisations identifiées pertinentes de la substance ou du mélange

What are the hazard statements for MOUSSE PU EXPANSIVE RÉSISTANTE AU FEU MANUELLE 750 ML ROUGE CLAIR?

This substance has 9 hazard statements: H222: Aérosol extrêmement inflammable. H229: Récipient sous pression: peut éclater sous l’effet de la chaleur. H315: Provoque une irritation cutanée. H317: Peut provoquer une allergie cutanée. H319: Provoque une sévère irritation des yeux. H334: Peut provoquer des symptômes allergiques ou d'asthme ou des difficultés respiratoires par inhalation. H335: Peut irriter les voies respiratoires. H351: Susceptible de provoquer le cancer (par inhalation). H373: Risque présumé d'effets graves pour les organes à la suite d'expositions répétées ou d'une exposition prolongée .

What is the melting point of MOUSSE PU EXPANSIVE RÉSISTANTE AU FEU MANUELLE 750 ML ROUGE CLAIR?

The melting point is Non concerné. and the boiling point is Non concerné..