NextSDS Logo
La

Lastinox TS pte

NO SIGNAL WORD pte SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Lastinox TS pte

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Pte de dcapage et de nettoyage des aciers inoxydables aprs soudage

Overview

Lastinox TS pte commonly used pte de dcapage et de nettoyage des aciers inoxydables aprs soudage.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

Hazard Classifications

Acute Tox. H300
Acute Tox. H310
Acute Tox. H330
Skin Corr. H314
Eye Dam. H314
STOT SE H335

GHS Hazard Pictograms & Safety Symbols

GHS05 GHS Hazard Pictogram: Corrosive hazard - Materials that can cause severe skin burns and eye damage

GHS05

GHS06 GHS Hazard Pictogram: Acute toxicity hazard - Poisonous materials that can cause death or serious harm

GHS06

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

  • P103: Lire l'tiquette avant utilisation
  • P260: Ne pas respirer les poussires / fumes / gaz / brouillards / vapeurs / arosols.
  • P262: Eviter tout contact avec les yeux, la peau ou les vetements.
  • P311: Appeler un CENTRE ANTIPOISON ou un mdecin.
  • P320: Un traitement spcifique et urgent (voirsur sette tiquette)
  • P501: Eliminer le contenu / rcipient dans un installation de traitement des dchets chimiques
  • Stocker dans un endroit bien ventil. Maintenir le rcipient ferm de manire tanche.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Lastek Belgium n.v./s.a.

manufacturer

📍

Industriepark Wolfstee, Toekomstlaan 50 - 2200 Herentals

🌍

BE

📠

014/22.32.91

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

📞

014/22.57.67

🌍

BE

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
acide fluorhydrique (HF)
EC: 231-634-8
7664-39-3 16% ✓ Non-hazardous
acide nitrique (HNO3)
EC: 231-714-2
7697-37-2 7% ✓ Non-hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

conduire la personne lair frais, veiller ce quelle nait pas froid. Garder au repos. Respiration irrgulire/arrt de respiration : respiration artificielle. Evanouissement : position latrale/appeler un mdecin.

Symptoms:

Respiration irrgulire/arrt de respiration, Evanouissement

🖐️ Skin Contact

enlever sans dlai les vtements souills. Laver avec de leau/du savon et rincer abondamment avec de leau.

👁️ Eye Contact

Retirer les lentilles de contact, garder les paupires ouvertes. Rincer avec beaucoup deau pendant au minimum 10-15 minutes, et consulter immdiatement un spcialiste/mdecin.

🍽️ Ingestion/Swallowing

appeler immdiatement un mdecin. Garder au repos. Ne pas vomir (risque de perforation).

Symptoms:

risque de perforation

🚨 Immediate Medical Attention Required

consulter immdiatement un spcialiste/mdecin (pour les yeux), appeler immdiatement un mdecin (pour l'ingestion). En cas de soupon dun effet systmatique, une surveillance intensive care et thrapie est ncessaire.

Medical Treatment

respiration artificielle, position latrale. En cas de soupon dun effet systmatique, une surveillance intensive care et thrapie est ncessaire. Consulter un docteur expriment de traitement des victimes d'acide fluorhydrique (HF).

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

🧪 Physical State
pte
Critical Property
📊 Physical State Data
Not available
📊 State Under Standard Conditions
Not available
👁️ Appearance
Not available
🎨 Colour
bleutre/ verdtre
📊 Colour Intensity
Not available
📊 Form
Not available
👃 Odor
au dbut lgre odeur dacide fluorhydrique
📊 Odor Threshold
Not available
🧪 Ph
<1 (20C)
🧊 Melting Point
p.d.d.
Critical Property
💨 Boiling Point
>120C
Critical Property
🔥 Flash Point
n.a.
Critical Property
📊 Freezing Point
Not available
📊 Softening Point
Not available
📊 Solidification Point
Not available
📊 Cloud Point
Not available
📊 Crystallisation Point
Not available
📊 Relative Evaporation Rate
Not available
💨 Evaporation Rate
Not available
💨 Vapor Pressure
<1000 hPa ( 20C)
📊 Vapor Density
Not available
📊 Relative Density
Not available
📊 Bulk Density
Not available
⚖️ Density
1 - 2 g/cm
Critical Property
🔥 Flammability
Not available
📊 Upper Explosive Limit
n.a.
📊 Lower Explosive Limit
n.a.
📊 Explosive Limits
Not available
📊 Auto Ignition Temperature
Not available
📊 Decomposition Temperature
Not available
💧 Solubility
Not available
📊 Partition Coefficient
Not available
📊 Solubility In Water
compltement
📊 Solubility In Fat
Not available
📊 Molecular Weight
Not available
📊 Voc Content
Not available
📊 Metal Corrosion
Not available
📊 Dynamic Viscosity
Not available
📊 Kinematic Viscosity
Not available
📊 Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Le lieu de travail doit être prévu d'une aspiration conforme à la législation sur l'environnement. L'air aspiré ne peut pas être soufflé sans filtrage (prévoir un dispositif de lavage : passage transversal, dans la même direction de courant ou contre courant)

🧤 Hand Protection

porter des gants appropriés (antiacide) en caoutchouc ou synthétique avec manchette. Matériaux appropriés : polychloroprène CR (0.5 mm), butylcaoutchouc butyl (0.5 mm), fluorcaoutchouc FKM (0.4 mm), polychlorure de vinyle PVC (0.5 mm). Le degré de protection et la durée d'emploi doivent être accordés avec votre fournisseur des moyens de protection.

👁️ Eye Protection

au minimum des lunettes de sûreté bien fermées en PC, ou mieux un écran visière en PC (résistant à l'acide fluorhydrique)

😷 Respiratory Protection

généralement : utiliser un appareil de protection respiratoire indépendant. En cas d'exposition courte (max. 30 min) et faible concentration, utiliser un filtre respiratoire. Exigences minimum filtre gaz combiné gris/bleu

🦺 Skin/Body Protection

porter des vêtements de protection antiacide, en PE-HD ou PP, et des chaussures de protection appropriées, en PP ou PE. Le degré de protection et la durée d'emploi doivent être accordés avec votre fournisseur des moyens de protection.

🌍 Environmental Exposure Controls

Prévoir un traitement physico-chimique approprié des eaux usées.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

🏷️ UN Number

UN2922

📦 Proper Shipping Name

corrosive liquid, toxic, n.o.s.

⚠️ Transport Hazard Class

8 (6.1)

📋 Packing Group

II

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Lastinox TS pte?

The signal word for this substance is "no signal word".

What is the physical form of Lastinox TS pte?

Lastinox TS pte is a pte with bleutre/ verdtre color. It has au dbut lgre odeur dacide fluorhydrique odor.

What is Lastinox TS pte used for?

Pte de dcapage et de nettoyage des aciers inoxydables aprs soudage

What is the melting point of Lastinox TS pte?

The melting point is p.d.d. and the boiling point is >120C.