Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
Jointfiller + is a poeder substance commonly used gipspleister.
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
GHS Hazard Pictograms & Safety Symbols
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
Precautionary Statements
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
Knauf S.C.S.
manufacturer
Rue du Parc Industriel, 1, B-4480 Engis
BE
+32 (0)4 273.83.11
+32 (0)4 273.83.30
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Antigif Centrum
+32 (0)70 245 245
BE
tijdens kantooruren
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
mixtureGeneral Composition
Calciumsulfaat op diverse graden van hydratie met additieven (cellulose ether, afgebroken eiwitten, oppervlakte-actieve stoffen)
Chemical Components & Hazardous Substances
Chemical Name | CAS Number | Concentration | Hazardous |
---|---|---|---|
Calciumsulfaat hemihydraat | 7778-18-9 | Not specified | β Non-hazardous |
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
π« Inhalation Exposure
Vermijd inademing van stof.
ποΈ Skin Contact
Wassen met water en zeep.
Symptoms:
Kan huidirritatie veroorzaken.
ποΈ Eye Contact
De ogen spoelen met stromend water. Raadpleeg een arts wanneer klachten aanhouden.
Symptoms:
Irritant voor de ogen.
π½οΈ Ingestion/Swallowing
Reinig de mond. Voldoende water drinken. Raadpleeg een arts.
Fire Fighting Measures & Emergency Response
Fire suppression methods, extinguishing media, and firefighting safety procedures
β Suitable Extinguishing Media
Gebruik een geschikt blusmiddel.
β Unsuitable Extinguishing Media
Niet van toepassing.
β οΈ Specific Fire Hazards
Niet van toepassing.
π‘οΈ Firefighter Protection Equipment
Ademhalingsuitrusting onafhankelijk van de binnenlucht dragen.
Accidental Release Measures & Spill Response
Emergency spill cleanup procedures, containment methods, and environmental protection
π Environmental Precautions
Vermijd dat het product in de riolering, oppervlaktewater of grondwater terecht komt.
π§Ή Cleanup Methods
Mechanisch, droog opnemen.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Safe Handling & Storage Procedures
Industrial handling precautions, storage conditions, and workplace safety requirements
β οΈ Handling Precautions
β’ Contact met ogen en huid vermijden.
β’ Inademing van stof vermijden.
β’ Zorg voor goed geventileerde ruimten.
πͺ Storage Conditions
β’ Droog en koel bewaren in goed afgesloten verpakking.
π₯ Fire Prevention Measures
Geen specifieke maatregelen vereist.
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
π§€ Hand Protection
Handschoenen. Handschoenmateriaal : Handschoenen in nitril gedrenkt katoen. Doordringtijd handschoenmateriaal : Raadpleeg de fabrikant/handelaar van beschermende middelen op geschiktheid en penetratietijd.
ποΈ Eye Protection
Veiligheidsbril met geΓ―ntegreerde zijbescherming.
π· Respiratory Protection
Respecteer de maximale grenswaarden (MAK = 10 mg/m3). Bij stofontwikkeling wordt het dragen van ademhalingsbescherming filtertype FFP2 aanbevolen.
π¦Ί Skin/Body Protection
Beschermende werkkledij.
Chemical Stability & Reactivity Data
Chemical stability, hazardous reactions, and incompatible materials information
β Chemical Stability
Geen ontleding bij correct gebruik en opslag. Inwerking van vocht vermijden.
βοΈ Reactivity
Geen verdere relevante informatie beschikbaar.
β οΈ Hazardous Reactions
Geen gevaarlijke reactie bekend.
π« Conditions to Avoid
Geen verdere relevante informatie beschikbaar.
π§ͺ Incompatible Materials
Onbekend.
π¨ Hazardous Decomposition Products
Geen gevaarlijke ontledingsproducten.
Ecological Information & Environmental Impact
Environmental toxicity, biodegradation, bioaccumulation, and ecological effects data
π± Toxiciteit
π± Persistentie en afbreekbaarheid
π± Bioaccumulatie
π± Mobiliteit in de bodem
π± Resultaten van PBT- en zPzB-beoordeling
π± Andere schadelijke effecten
Waste Disposal & Treatment Methods
Waste disposal procedures, treatment methods, and regulatory compliance requirements
β»οΈ Waste Treatment Methods
Afval verwijderen volgens de geldende wettelijke voorschriften.
ποΈ Product Disposal Recommendations
Verontreinigde verpakkingen volledig ledigen en kunnen na reinigen volgens de geldende voorschriften gerecycleerd worden. Verwijderen als bouwafval volgens de wettelijke voorschriften.
π·οΈ Waste Classification Codes
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
β οΈ Transport Hazard Class
Niet gereglementeerd
Regulatory Information & Compliance
Chemical regulations, safety assessments, and regulatory compliance status
π Regulatory Summary
Het product is niet onderworpen aan etikettering conform de verordening 1907/2006/EG betreft de klassering, etikettering en verpakking van gevaarlijke stoffen. Geen enkel bestanddeel is inbegrepen. Calciumsulfaat is niet onderworpen aan de etikettering volgens de richtlijnen met betrekking tot gevaarlijke stoffen. Het product is geen afvalstof die speciale behandeling noodzaakt in het kader van afvalstoffenrichtlijn. Vervuilingsklasse van het water: Niet giftig.
β Chemical Safety Assessment
No chemical safety assessment has been performed for this substance.
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for Jointfiller +?
The signal word for this substance is "no signal word".
What is Jointfiller + used for?
Gipspleister
What is the melting point of Jointfiller +?