NextSDS Logo
PT

PT185 POWERTINT(R) RED OXIDE

WARNING liquid SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
PT185 POWERTINT(R) RED OXIDE
Product Code
PT185

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
gebaseerd op gebruiksbeschrijvingssysteem afgegeven als richtlijn van het Europees Agentschap voor Chemische stoffen
Uses Advised Against
niet voor enig huishoudelijk gebruik

Overview

PT185 POWERTINT(R) RED OXIDE commonly used gebaseerd op gebruiksbeschrijvingssysteem afgegeven als richtlijn van het europees agentschap voor chemische stoffen.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Waarschuwing)

Hazard Classifications

Flam. Liq. Category 3 H226

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H226: Ontvlambare vloeistof en damp.

Precautionary Statements

  • P210: Verwijderd houden van warmte/vonken/open vuur/hete oppervlakken. - Niet roken.
  • P403 + P235: Op een goed geventileerde plaats bewaren. Koel bewaren.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Axalta Coating Systems Germany GmbH company logo - Safety Data Sheet supplier organization

Axalta Coating Systems Germany GmbH

manufacturer

Horbeller Str. 15, DE 50858 Köln

DE

+49(0) 2234 6019-01

+49 (0)202 529-2804

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

fabrikant

+31 (0)78 630-1899

NL

nationaal telefoonnummer voor noodgevallen

070 245.245

NL

vereist door verordening 1907/2006 annex II

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Mengsel uit synthetische kunstharsen, pigmenten en oplosmiddelen.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
N-BUTYLACETATE
EC: 204-658-1
123-86-4 15-20% Hazardous
heptane-2-one
EC: 203-767-1
110-43-0 5-7% Hazardous
exo-1,7,7-trimethylbicyclo[2.2.1]hept-2-ylmethacrylaat
EC: 231-403-1
7534-94-3 0.1-0.2% Hazardous

Additional Information

Volledige tekst van de R-zinnen: zie hoofdstuk16. Volledige tekst van de H-zinnen: zie hoofdstuk16.

Composition Notes

Gezondheids- of milieugevaarlijke stoffen volgens Richtlijn 67/548/EEG.

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Voorkom inademing van damp of nevel. In de frisse lucht brengen na onopzettelijk inademen van dampen. Bij onregelmatige ademhaling of ademstilstand kunstmatige beademing toepassen. Bij bewusteloosheid de patiënt in stabiele zijligging leggen en medische hulp inroepen.

Skin Contact

Verontreinigde kleding onmiddellijk uittrekken.

Eye Contact

Contactlenzen uitnemen. Oogleden openhouden en minstens 15 minuten met veel water spoelen. Medische hulp inroepen.

Ingestion/Swallowing

In geval van inslikken onmiddellijk een arts raadplegen en verpakking of etiket tonen. GEEN braken opwekken. Rustig houden.

Immediate Medical Attention Required

Bij bewusteloosheid de patiënt in stabiele zijligging leggen en medische hulp inroepen.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Physical State
liquid
Critical Property
Physical State Data
liquid
State Under Standard Conditions
Not available
Appearance
Not available
Colour
red
Colour Intensity
Not available
Form
liquid
Odor
no odor detectable
Odor Threshold
Not available
Ph
pH cannot be measured due to lower solubility in water.
Melting Point
Not available
Boiling Point
152 ℃
Critical Property
Flash Point
31 °C
Critical Property
Freezing Point
Not available
Softening Point
Not available
Solidification Point
Not available
Cloud Point
Not available
Crystallisation Point
Not available
Relative Evaporation Rate
Not available
Evaporation Rate
Slower than ether
Vapor Pressure
3.1 hPa
Vapor Density
no data available
Relative Density
1.57 g/cm3
Bulk Density
Not available
Density
Not available
Flammability
not relevant, since the product is liquid 1.1 vol-% based on the content of organic solvent
Upper Explosive Limit
7.9 vol-% based on the content of organic solvent
Lower Explosive Limit
1.1 vol-% based on the content of organic solvent
Explosive Limits
Not available
Auto Ignition Temperature
393 ℃
Decomposition Temperature
This product is a mixture. See section 10 for further information.
Solubility
partially miscible with most organic solvents
Partition Coefficient
This product is a mixture. see section 12 for details
Solubility In Water
partially miscible
Solubility In Fat
Not available
Molecular Weight
Not available
Voc Content
24.3 %
Metal Corrosion
Not available
Dynamic Viscosity
Not available
Kinematic Viscosity
23 s
Properties Status
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Zorg voor voldoende luchtverversing. Dit kan bereikt worden door goede algemene afzuiging of, waar praktisch uitvoerbaar, plaatselijke afzuigventilatie.

Hand Protection

De doordringingtijd van de handschoenen voor de stof zelf is onbekend. Het omschreven materiaal voor de handschoenen wordt aanbevolen op basis van de bestanddelen van het preparaat. Voor n-butylacetaat: Viton (R) ®, 0,7 mm, 10 min; Nitrilrubber, 0,33 mm, 30 min. De beschermende handschoen moet in alle gevallen worden gecontroleerd op werkplaatsspecifieke geschiktheid (bijvoorbeeld mechanische bestendigheid, productcompatibiliteit, antistatische eigenschappen). Voor bescherming bij spuiten moet een beschermende nitrilhandschoen van chemicaliënbestendigheidsgroep 3 (bijv. Dermatril®) worden gebruikt. Na verontreiniging moet de handschoen worden verwisseld. Bij onderdompeling van de handen in het product moet een butyl- of fluorrubber handschoen worden gedragen. Handschoenen moeten bij beschadiging of eerste tekenen van slijtage meteen worden vervangen.

Eye Protection

Ter bescherming van spatten van het oplosmiddel veiligheidsbril dragen.

Respiratory Protection

Als de stofconcentratie en oplosmiddelconcentratie boven de MAC waarde komen, moet geschikte adembescherming worden gedragen. Masker met gasfilter, type A (EN 141). Indien personeel wordt blootgesteld aan een niveau boven het maximum, moeten zij gebruik maken van de juiste, goedgekeurde ademhalingsbescherming.

Skin/Body Protection

Draag geschikte beschermende kleding. Antistatische kleding uit natuurlijke vezels (katoen) of synthetische vezels dragen die bestand is tegen hitte.

Environmental Exposure Controls

Product niet in de riolering laten komen. Zie hoofdstuk 12 voor ecologische informatie.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

1263

Proper Shipping Name

VERF

Transport Hazard Class

3

Packing Group

III

ADR Transport Precautions

zie deel 6 - 8

IMDG Maritime Transport Precautions

zie deel 6 - 8

IATA Air Transport Precautions

zie deel 6 - 8

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for PT185 POWERTINT(R) RED OXIDE?

The signal word for this substance is "warning".

What is the physical form of PT185 POWERTINT(R) RED OXIDE?

PT185 POWERTINT(R) RED OXIDE is a liquid with red color. It has no odor detectable odor.

What is the solubility of PT185 POWERTINT(R) RED OXIDE?

partially miscible with most organic solvents

What is PT185 POWERTINT(R) RED OXIDE used for?

gebaseerd op gebruiksbeschrijvingssysteem afgegeven als richtlijn van het Europees Agentschap voor Chemische stoffen

What are the hazard statements for PT185 POWERTINT(R) RED OXIDE?

This substance has 1 hazard statements: H226: Ontvlambare vloeistof en damp.