Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
SIGMACOVER 300 LT (SIGMA TCN 300 LT) BASE is a viskeus substance .
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
Precautionary Statements
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
Sigma Coatings BV
manufacturer
Amsterdamsewcg 14 1422 AD Uithoorn
NL
+31297541911
+31297541050
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Emergency Contact
+31204075210
NL
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
mixtureChemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| POLYAMINE EPOXY ADDUCT | N/A | 10-25% | β Non-hazardous |
| xylcen EC: 215-535-7 | 1330-20-7 | 10-25% | β οΈ Hazardous |
| 2-methylpropaan-1-ol EC: 201-148-0 | 78-83-1 | 10-25% | β οΈ Hazardous |
| ethylbcnzeen EC: 202-849-4 | 100-41-4 | 2.5-10% | β οΈ Hazardous |
| 2,4,6-TRI(DIMETHYLAMINOMETHYL) FENOL EC: 202-013-9 | 90-72-2 | 2.5-10% | β οΈ Hazardous |
| 1-METHOXY-2-PROPANQL EC: 203-539-1 | 107-98-2 | 10-25% | β οΈ Hazardous |
| 4,4'-ISOPROPYLIDEENDIFENOL EC: 201-245-8 | 80-05-7 | 2.5-10% | β οΈ Hazardous |
| 4-NONYLPHENOL, BRANCHED EC: 284-325-5 | 84852-15-3 | 2.5% | β οΈ Hazardous |
Composition Notes
Zie voor componenten met een wettelijke grenswaarde (MAC) hoofdstuk 8.
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
π« Inhalation Exposure
Verse lucht toedienen. Betreffende persoon in rusttoestand brengen en warm houden. Bij onregelmatige ademhaling of ademstilstand kunstmatige beademing toepassen. Bij bewusteloosheid stabiele zijligging toepassen en medisch advies inwinnen.
Symptoms:
Onregelmatige ademhaling of ademstilstand, bewusteloosheid.
ποΈ Skin Contact
Verontreinigde kleding onmiddellijk uittrekken. De huid grondig wassen met water en zeep of een erkende huidreiniger. GEEN oplosmiddelen of verfverdunner gebruiken.
ποΈ Eye Contact
Oogleden openhouden en minstens 10 minuten lang rijkelijk met zuiver, vloeiend water spoelen. Contactlenzen uitdoen. Medisch advies inwinnen.
π½οΈ Ingestion/Swallowing
Bij inslikken direct arts raadplegen. Het slachtoffer laten rusten. Geen braken opwekken.
π¨ Immediate Medical Attention Required
Medische hulp dient te worden ingeroepen als de ziekteverschijnselen niet van voorbijgaande aard zijn of in geval van twijfel. Medisch advies inwinnen bij oogcontact, bewusteloosheid na inademing, of direct arts raadplegen bij inslikken.
Medical Treatment
Bij onregelmatige ademhaling of ademstilstand kunstmatige beademing toepassen.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
π Engineering Controls
Minimale hoeveelheid te ventileren lucht die nodig is voor 1 liter product: Om de MAC te bereiken: 2,389 m3/l (Basis: MAC (NL)), Om 10% OEG te bereiken: 110 m3/l. Indien werknemers - ook als ze niet zelf bezig zijn met de verwerking van het product - zich in een spuitcabine bevinden, dient ventilatie aanwezig te zijn voor eventuele spuitdeeltjes en oplosmiddeldampen.
π§€ Hand Protection
Bij langer of herhaaldelijk contact handschoenen gebruiken.
ποΈ Eye Protection
Het dragen van een chemicaliΓ«nbestendige beschermingsbril is verplicht.
π· Respiratory Protection
In deze omstandigheden dienen zij een verse-lucht kap te dragen tijdens het spuitproces tot het moment dat de concentratie is gedaald tot beneden de MAC-waarde.
π¦Ί Skin/Body Protection
Het personeel dient beschermende kleding te dragen. Werkkleding dient niet uit textiel te bestaan, dat in geval van brand een gevaarlijk smeltgedrag vertoont. Het dragen van antistatische schoenen is verplicht.
Chemical Stability & Reactivity Data
Chemical stability, hazardous reactions, and incompatible materials information
β οΈ Hazardous Reactions
Verwijderd houden van oxidatiemiddelen, sterk alkalische en sterk zure materialen om exothermische reacties te vermijden.
π« Conditions to Avoid
Vermijd temperaturen boven 60Β°C (140 F), direct zonlicht en aanraking met warmtebronnen.
π§ͺ Incompatible Materials
oxidatiemiddelen, sterk alkalische en sterk zure materialen
π¨ Hazardous Decomposition Products
Bij brand kunnen gevaarlijke ontledingsproducten worden gevormd zoals: Koolzuur (CO2), koolmonoxide (CO), stikstofoxiden (NOx), dichte zwarte rook.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
π·οΈ UN Number
2924
π¦ Proper Shipping Name
FLAMMABLE LIQUID, CORROSIVE, N.O.S.
β οΈ Transport Hazard Class
3
π Packing Group
III
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for SIGMACOVER 300 LT (SIGMA TCN 300 LT) BASE?
The signal word for this substance is "na: r-phrases".