NextSDS Logo
SI

SIGMACOVER 300 LT (SIGMA TCN 300 LT) BASE

NA: R-PHRASES SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
SIGMACOVER 300 LT (SIGMA TCN 300 LT) BASE
Product Code
634100

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Overview

SIGMACOVER 300 LT (SIGMA TCN 300 LT) BASE is a viskeus substance .

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

na: r-phrases

Hazard Classifications

BIJtend

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Sigma Coatings BV

manufacturer

πŸ“

Amsterdamsewcg 14 1422 AD Uithoorn

🌍

NL

πŸ“ž

+31297541911

πŸ“ 

+31297541050

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

πŸ“ž

+31204075210

🌍

NL

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
POLYAMINE EPOXY ADDUCT N/A 10-25% βœ“ Non-hazardous
xylcen
EC: 215-535-7
1330-20-7 10-25% ⚠️ Hazardous
2-methylpropaan-1-ol
EC: 201-148-0
78-83-1 10-25% ⚠️ Hazardous
ethylbcnzeen
EC: 202-849-4
100-41-4 2.5-10% ⚠️ Hazardous
2,4,6-TRI(DIMETHYLAMINOMETHYL) FENOL
EC: 202-013-9
90-72-2 2.5-10% ⚠️ Hazardous
1-METHOXY-2-PROPANQL
EC: 203-539-1
107-98-2 10-25% ⚠️ Hazardous
4,4'-ISOPROPYLIDEENDIFENOL
EC: 201-245-8
80-05-7 2.5-10% ⚠️ Hazardous
4-NONYLPHENOL, BRANCHED
EC: 284-325-5
84852-15-3 2.5% ⚠️ Hazardous

Composition Notes

Zie voor componenten met een wettelijke grenswaarde (MAC) hoofdstuk 8.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Verse lucht toedienen. Betreffende persoon in rusttoestand brengen en warm houden. Bij onregelmatige ademhaling of ademstilstand kunstmatige beademing toepassen. Bij bewusteloosheid stabiele zijligging toepassen en medisch advies inwinnen.

Symptoms:

Onregelmatige ademhaling of ademstilstand, bewusteloosheid.

πŸ–οΈ Skin Contact

Verontreinigde kleding onmiddellijk uittrekken. De huid grondig wassen met water en zeep of een erkende huidreiniger. GEEN oplosmiddelen of verfverdunner gebruiken.

πŸ‘οΈ Eye Contact

Oogleden openhouden en minstens 10 minuten lang rijkelijk met zuiver, vloeiend water spoelen. Contactlenzen uitdoen. Medisch advies inwinnen.

🍽️ Ingestion/Swallowing

Bij inslikken direct arts raadplegen. Het slachtoffer laten rusten. Geen braken opwekken.

🚨 Immediate Medical Attention Required

Medische hulp dient te worden ingeroepen als de ziekteverschijnselen niet van voorbijgaande aard zijn of in geval van twijfel. Medisch advies inwinnen bij oogcontact, bewusteloosheid na inademing, of direct arts raadplegen bij inslikken.

Medical Treatment

Bij onregelmatige ademhaling of ademstilstand kunstmatige beademing toepassen.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

πŸ§ͺ Physical State
Not available
πŸ“Š Physical State Data
Not available
πŸ“Š State Under Standard Conditions
Not available
πŸ‘οΈ Appearance
viskeus
🎨 Colour
geel
πŸ“Š Colour Intensity
Not available
πŸ“Š Form
viskeus
πŸ‘ƒ Odor
sterk aromatisch
πŸ“Š Odor Threshold
Not available
πŸ§ͺ Ph
Not available
🧊 Melting Point
Not available
πŸ’¨ Boiling Point
Not available
πŸ”₯ Flash Point
31.0 C
Critical Property
πŸ“Š Freezing Point
Not available
πŸ“Š Softening Point
Not available
πŸ“Š Solidification Point
Not available
πŸ“Š Cloud Point
Not available
πŸ“Š Crystallisation Point
Not available
πŸ“Š Relative Evaporation Rate
Not available
πŸ’¨ Evaporation Rate
Not available
πŸ’¨ Vapor Pressure
Not available
πŸ“Š Vapor Density
Not available
πŸ“Š Relative Density
Not available
πŸ“Š Bulk Density
Not available
βš–οΈ Density
0.95 g/cmΒ³ bij 20 Β°C
Critical Property
πŸ”₯ Flammability
Not available
πŸ“Š Upper Explosive Limit
Not available
πŸ“Š Lower Explosive Limit
1.24 % (V)
πŸ“Š Explosive Limits
Not available
πŸ“Š Auto Ignition Temperature
Not available
πŸ“Š Decomposition Temperature
Not available
πŸ’§ Solubility
Not available
πŸ“Š Partition Coefficient
Not available
πŸ“Š Solubility In Water
niet mengbaar
πŸ“Š Solubility In Fat
Not available
πŸ“Š Molecular Weight
Not available
πŸ“Š Voc Content
Not available
πŸ“Š Metal Corrosion
Not available
πŸ“Š Dynamic Viscosity
200 mPa.s bij 23 Β°C
πŸ“Š Kinematic Viscosity
Not available
πŸ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Minimale hoeveelheid te ventileren lucht die nodig is voor 1 liter product: Om de MAC te bereiken: 2,389 m3/l (Basis: MAC (NL)), Om 10% OEG te bereiken: 110 m3/l. Indien werknemers - ook als ze niet zelf bezig zijn met de verwerking van het product - zich in een spuitcabine bevinden, dient ventilatie aanwezig te zijn voor eventuele spuitdeeltjes en oplosmiddeldampen.

🧀 Hand Protection

Bij langer of herhaaldelijk contact handschoenen gebruiken.

πŸ‘οΈ Eye Protection

Het dragen van een chemicaliΓ«nbestendige beschermingsbril is verplicht.

😷 Respiratory Protection

In deze omstandigheden dienen zij een verse-lucht kap te dragen tijdens het spuitproces tot het moment dat de concentratie is gedaald tot beneden de MAC-waarde.

🦺 Skin/Body Protection

Het personeel dient beschermende kleding te dragen. Werkkleding dient niet uit textiel te bestaan, dat in geval van brand een gevaarlijk smeltgedrag vertoont. Het dragen van antistatische schoenen is verplicht.

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

⚠️ Hazardous Reactions

Verwijderd houden van oxidatiemiddelen, sterk alkalische en sterk zure materialen om exothermische reacties te vermijden.

🚫 Conditions to Avoid

Vermijd temperaturen boven 60Β°C (140 F), direct zonlicht en aanraking met warmtebronnen.

πŸ§ͺ Incompatible Materials

oxidatiemiddelen, sterk alkalische en sterk zure materialen

πŸ’¨ Hazardous Decomposition Products

Bij brand kunnen gevaarlijke ontledingsproducten worden gevormd zoals: Koolzuur (CO2), koolmonoxide (CO), stikstofoxiden (NOx), dichte zwarte rook.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

🏷️ UN Number

2924

πŸ“¦ Proper Shipping Name

FLAMMABLE LIQUID, CORROSIVE, N.O.S.

⚠️ Transport Hazard Class

3

πŸ“‹ Packing Group

III

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for SIGMACOVER 300 LT (SIGMA TCN 300 LT) BASE?

The signal word for this substance is "na: r-phrases".