NextSDS Logo
SI

SIGMACOVER 435 BASE

NO SIGNAL WORD SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
SIGMACOVER 435 BASE
Product Code
PR-974973

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
verf

Overview

SIGMACOVER 435 BASE commonly used verf.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word (Schadelijk)

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

PPG Coatings SPRL/BVBA

manufacturer

๐Ÿ“

Noordersingel 23 B-2040 Borgerhout

๐ŸŒ

BE

๐Ÿ“ž

+32 3 3606311

๐Ÿ“ 

+32 3 3606435

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+31 20 4075210

๐ŸŒ

NL

NATIONAL POISONS INFORMATION CENTRE

๐Ÿ“ž

+31 30 2748888

๐ŸŒ

NL

CENTRE ANTI-POISONS/ANTIGIFCENTRUM

๐Ÿ“ž

+32 70 245 245

๐ŸŒ

BE

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

De producent verklaart dat voor de in hoofdstuk 3 niet vermelde R-zinnen, de totale hoeveelheid gevaarlijke componenten beneden de grens liggen.Het benzeengehalte van dit product is minder dan 0,1%.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
xyleen
EC: 215-535-7
1330-20-7 10-12.5% โš ๏ธ Hazardous
2-methylpropaan-1-ol
EC: 201-148-0
78-83-1 1-2.5% โš ๏ธ Hazardous
ethylbenzeen
EC: 202-849-4
100-41-4 2.5-10% โš ๏ธ Hazardous
reactieprodukt: bisfenolA-epichloorhydrine epoxyhars 25068-38-6 5-10% โš ๏ธ Hazardous
1-methoxy-2-propanol
EC: 203-539-1
107-98-2 1-2.5% โš ๏ธ Hazardous
nonylfenol
EC: 246-672-0
25154-52-3 1-2.5% โš ๏ธ Hazardous
aluminium
EC: 231-072-3
7429-90-5 2.5-10% โš ๏ธ Hazardous
nafta (aardolie), met waterstof behandeld zwaar
EC: 265-150-3
64742-48-9 1-2.5% โš ๏ธ Hazardous

Additional Information

Dit veiligheidsinformatieblad is opgesteld overeenkomstig Bijlage I van Verordening (EG) nr. 453/2010.

Composition Notes

Nota P en H zijn van toepassing. - Kandidaat-lijst van zeer zorgwekkende stoffen voor autorisatie

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Verse lucht toedienen. Betreffende persoon in rusttoestand brengen en warm houden. Bij onregelmatige ademhaling of ademstilstand kunstmatige beademing toepassen. Bij bewusteloosheid stabiele zijligging toepassen en medische advies inwinnen.

๐Ÿ–๏ธ Skin Contact

Verontreinigde kleding onmiddellijk uittrekken. De huid grondig wassen met water en zeep of een erkende huidreiniger.

๐Ÿ‘๏ธ Eye Contact

Oogleden openhouden en minstens 10 minuten lang rijkelijk met zuiver, vloeiend water spoelen. Contactlenzen uitdoen. Medisch advies inwinnen.

๐Ÿฝ๏ธ Ingestion/Swallowing

Bij inslikken direkt arts raadplegen. Het slachtoffer laten rusten.

๐Ÿšจ Immediate Medical Attention Required

Als de ziekteverschijnselen niet van voorbijgaande aard zijn en in geval van twijfel dient medische hulp te worden ingeroepen. Bij een ongeval of indien men zich onwel voelt onmiddellijk een arts raadplegen (indien mogelijk het etiket tonen). Dit veiligheidsinformatieblad aan de dienstdoende arts tonen.

Medical Treatment

Symptomatisch behandelen.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Not available
๐Ÿ“Š Physical State Data
Not available
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
verscheidene
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
viskeus
๐Ÿ‘ƒ Odor
mild aromatisch
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
Not available
๐ŸงŠ Melting Point
Not available
๐Ÿ’จ Boiling Point
Not available
๐Ÿ”ฅ Flash Point
29.3 C
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
Not available
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
1.53 g/cm3 bij 20 C
Critical Property
๐Ÿ”ฅ Flammability
Not available
๐Ÿ“Š Upper Explosive Limit
7.72 %(V)
๐Ÿ“Š Lower Explosive Limit
1.02 %(V)
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
- 430 C
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not available
๐Ÿ“Š Solubility In Water
te verwaarlozen
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
3,000 mPa.s bij 23 C
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Ventilation must be present for any spray particles and solvent vapors, especially if workers are in a spray booth. This includes local exhaust ventilation to reduce exposure.

๐Ÿงค Hand Protection

For prolonged or repeated contact, use chemical-resistant gloves as indicated in standard EN 374: Protective gloves against chemicals and microorganisms. Recommended gloves: Viton (R) with a minimum breakthrough time of 480 minutes. For long-term and regular contact, a glove with protection class 6 (breakthrough time more than 480 minutes according to EN 374) is recommended. For short contact, a glove with protection class 2 or higher (breakthrough time greater than 30 minutes according to EN 374) is recommended. The choice of specific gloves should be based on all relevant workplace factors, including other chemicals used, physical requirements, possible body reactions to glove material, and supplier instructions.

๐Ÿ‘๏ธ Eye Protection

Wearing chemical-resistant safety glasses is mandatory. Sealed glasses are recommended.

๐Ÿ˜ท Respiratory Protection

If workers are in a spray booth, they must wear a fresh-air hood during the spraying process until the concentration has fallen below the MAC value. A P2A2 half-face combination mask is recommended.

๐Ÿฆบ Skin/Body Protection

Personnel must wear protective clothing. Wash thoroughly after skin contact. Work clothing should not consist of textiles that exhibit dangerous melting behavior in case of fire. Wearing anti-static shoes is mandatory.

๐ŸŒ Environmental Exposure Controls

Refer to national legislation in chapter 15 for regulations regarding environmental protection.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

1263

๐Ÿ“ฆ Proper Shipping Name

PAINT

โš ๏ธ Transport Hazard Class

3

๐Ÿ“‹ Packing Group

III

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for SIGMACOVER 435 BASE?

The signal word for this substance is "no signal word".

What is SIGMACOVER 435 BASE used for?

verf