Product Name
Buz Mark Ex

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

UFI Code
FS50-3026-700E-5M4Q

Unique Formula Identifier - for poison centres and emergency response

Uses Information

Identified Uses
EuPCS: PC-CLN-OTH Andere reinigings-, verzorgings- en onderhoudsmiddelen (uitgezonderd biociden) Procescategorien [PROC]: 11

Overview

Buz Mark Ex commonly used eupcs: pc-cln-oth andere reinigings-, verzorgings- en onderhoudsmiddelen (uitgezonderd biociden) procescategorien [proc]: 11.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Gevaar)

Hazard Classifications

Eye Dam. Category 1 H318

GHS Hazard Pictograms & Safety Symbols

GHS05 GHS Hazard Pictogram: Corrosive hazard - Materials that can cause severe skin burns and eye damage

GHS05

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H318: Veroorzaakt ernstig oogletsel.

Precautionary Statements

  • P280: Beschermende handschoenen/beschermende kleding/oogbescherming/gelaatsbescherming dragen.
  • P305 + P351 + P338: BIJ CONTACT MET DE OGEN: voorzichtig afspoelen met water gedurende een aantal minuten; contactlenzen verwijderen, indien mogelijk; blijven spoelen.
  • P310: Onmiddellijk een ANTIGIFCENTRUM/arts raadplegen.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

BUZIL-WERK Wagner GmbH & Co. KG company logo - Safety Data Sheet supplier organization

BUZIL-WERK Wagner GmbH & Co. KG

manufacturer

Fraunhofer Str. 17 D-87700 Memmingen

DE

+49 (0) 8331 930-880

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

+49 (0) 8331 930-6

DE

08:00 - 16:00 h

Nationaal Vergiftigingen Informatie Centrum (NVIC)

+31 088 755 8000

NL

Uitsluitend bestemd om profesionele hulpverlenders te informeren bij acute vergiftingen

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

parfums (Limonene, Linalool, Citral)

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Propaan-2-ol; Isopropylalcohol; Isopropanol
EC: 200-661-7
67-63-0 10-15% Hazardous
1-ethoxypropan-2-ol
EC: 216-374-5
1569-02-4 5-10% Hazardous
2-phenoxy ethanol
EC: 204-589-7
122-99-6 5-10% Hazardous
2-(2-butoxyethoxyethanol)
EC: 203-961-6
112-34-5 5-10% Hazardous
Limonene N/A Not specified Non-hazardous
Linalool N/A Not specified Non-hazardous
Citral N/A Not specified Non-hazardous

Composition Notes

Volledige inhoud van de H- en EUH-zinnen: zie rubriek 16.

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Voor frisse lucht zorgen.

Skin Contact

Na aanraking met de huid onmiddellijk wassen met veel water en zeep. Verontreinigde kleding uittrekken en wassen alvorens deze opnieuw te gebruiken.

Eye Contact

Direct voorzichtig en grondig met oogdouche of met water spoelen.

Ingestion/Swallowing

Onmiddellijk mond spoelen en veel water drinken.

Medical Treatment

Symptomatische behandeling.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Lower Explosive Limit
niet bepaald
Solubility In Water
volledig mengbaar
Relative Evaporation Rate
Not available
Solidification Point
Not available
Upper Explosive Limit
niet bepaald
Vapor Density
Not available
Explosive Limits
Not available
Auto Ignition Temperature
niet bepaald
Cloud Point
Not available
Odor
Parfums, geurmiddelen
Physical State Data
liquid
Melting Point
ca. -5 C
Critical Property
Bulk Density
Not available
Flash Point
44 C
Critical Property
Dynamic Viscosity
< 10 mPas (50 1/s)
Colour Intensity
Not available
Solubility
Not available
Properties Status
Not available
Physical State
Vloeibaar
Critical Property
Flammability
niet van toepassing
Partition Coefficient
niet van toepassing
Boiling Point
- 90 C
Critical Property
Vapor Pressure
niet bepaald
Evaporation Rate
Not available
Metal Corrosion
Not available
Relative Density
niet bepaald
Softening Point
Not available
Form
Not available
Odor Threshold
Not available
Appearance
Not available
Freezing Point
Not available
Colour
kleurloos - lichtgeel
State Under Standard Conditions
Not available
Density
0,99 g/cm
Critical Property
Molecular Weight
Not available
Kinematic Viscosity
niet bepaald
Solubility In Fat
Not available
Crystallisation Point
Not available
Ph
9 - 10
Decomposition Temperature
niet van toepassing
Voc Content
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Hand Protection

Draag geschikte handschoenen. (EN 374, Categorie III) Bij de omgang met chemische werkstoffen mogen handschoenen die tegen chemicalin beschermen met CE-kenmerk inclusief het viercijferige controlenummer, gedragen worden. Geschikt materiaal: NBR (Nitrilrubber) / dikte van het handschoenenmateriaal > 0,1 mm Het gebruik van veiligheidshandschoenen is niet nodig indien gelijkwaardige veiligheidsmaatregelen met inachtneming van een verhoogde huidbelasting door vochtig werk worden getroffen (bijv. gebruik van geschikte huidbeschermingszalf).

Eye Protection

Draag oogbescherming/gelaatsbescherming. (EN 166)

Respiratory Protection

Uitsluitend op goed geventileerde plaatsen gebruiken.

Skin/Body Protection

Draag geschikte werkkleding.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Buz Mark Ex?

The signal word for this substance is "danger".

What is the physical form of Buz Mark Ex?

Buz Mark Ex is a vloeibaar with kleurloos - lichtgeel color. It has parfums, geurmiddelen odor.

What is Buz Mark Ex used for?

EuPCS: PC-CLN-OTH Andere reinigings-, verzorgings- en onderhoudsmiddelen (uitgezonderd biociden) Procescategorien [PROC]: 11

What are the hazard statements for Buz Mark Ex?

This substance has 1 hazard statements: H318: Veroorzaakt ernstig oogletsel.

What is the melting point of Buz Mark Ex?

The melting point is ca. -5 C and the boiling point is - 90 C.