NextSDS Logo
Cu

Cut and Drill Fluid 2

DANGER Aërosol SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Cut and Drill Fluid 2
Product Code
85238

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Smeerolie

Overview

Cut and Drill Fluid 2 commonly used smeerolie.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Gevaar)

Hazard Classifications

Aerosol Category 1 H222
Aquatic Chronic Category 2 H411
STOT SE Category 3 H336
Lact. H362

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS09 GHS Hazard Pictogram: Environmental hazard - Materials toxic to aquatic life and environment

GHS09

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H222: Zeer licht ontvlambare aerosol.
  • H229: Houder onder druk: kan open barsten bij verhitting.
  • H336: Kan slaperigheid of duizeligheid veroorzaken.
  • H362: Kan schadelijk zijn via borstvoeding.
  • H411: Giftig voor in het water levende organismen, met langdurige gevolgen.

Precautionary Statements

  • P210: Verwijderd houden van warmte, hete oppervlakken, vonken, open vuur en andere ontstekingsbronnen. Niet roken.
  • P211: Niet in een open vuur of op andere ontstekingsbronnen spuiten.
  • P251: Ook na gebruik niet doorboren of verbranden.
  • P260: Nevel/damp/spuitnevel niet inademen.
  • P302 + P352: BIJ CONTACT MET DE HUID: Met veel water en zeep wassen.
  • P304 + P340: NA INADEMING: de persoon in de frisse lucht brengen en ervoor zorgen dat deze gemakkelijk kan ademen.
  • P308 + P313: NA (mogelijke) blootstelling: een arts raadplegen.
  • P410 + P412: Tegen zonlicht beschermen. Niet blootstellen aan temperaturen boven 50 °C/122 °F.
  • P501: De inhoud en de verpakking verwerken volgens de plaatselijke/regionale/nationale/internationale voorschriften.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

KENT Belux SPRL/BVBA

manufacturer

Rue Emile Francqui 4 B-1435 Mont-Saint-Guibert

BE

KENT Nederland BV

manufacturer

Claudius Prinsenlaan 128 NL-4818 CP Breda

NL

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

+ 32 10 48 76 40 (tussen 08.15 en 16.45 uur)

BE

tussen 08.15 en 16.45 uur

Antigifcentrum

070 245 245

24 uur op 24

Noodnummer

Emergency Contact

+ 31 85 4868360 (tussen 08.15 en 16.45 uur)

NL

tussen 08.15 en 16.45 uur

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Mengsel bestaande uit hierna genoemde stoffen.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
propaan vloeibaargemaakt
EC: 200-827-9
74-98-6 10-25% Hazardous
N/A N/A 10-25% Hazardous
butaan, zuiver
EC: 203-448-7
106-97-8 1-10% Hazardous
xyleen, mengsel van isomeren, zuiver
EC: 215-535-7
1330-20-7 3% Hazardous
isobutaan
EC: 200-857-2
75-28-5 5% Hazardous
alkanen, C14-17, chloor chloorparaffines, C14-17
EC: 287-477-0
85535-85-9 5% Hazardous

Additional Information

De woordelijke inhoud van de opgegeven aanwijzingen inzake de mogelijke gevaren is te vinden in hoofdstuk 16.

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Verse lucht aanvoeren, eventueel beademing, warmte. Wanneer de klachten niet ophouden, een arts consulteren. Bij bewusteloosheid ligging en vervoer in stabiele zijligging.

Skin Contact

Onmiddellijk met water en zeep afwassen en goed naspoelen. Wanneer de huid geïrriteerd blijft, een dokter opzoeken.

Eye Contact

De ogen gedurende verscheidene minuten onder stromend water afspoelen terwijl de oogspleet geopend blijft. Bij aanhoudende klachten een dokter raadplegen.

Ingestion/Swallowing

Geen braken teweegbrengen en onmiddellijk bijstand van arts inroepen. Mond spoelen en overvloedig water drinken.

Fire Safety

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

Suitable Extinguishing Media

CO2, bluspoeder of waternevel. Grotere brand met waternevel of met schuim dat tegen alcohol bestand is bestrijden.

Unsuitable Extinguishing Media

Krachtige waterstraal.

Specific Fire Hazards

Kan ontplofbaar gas-lucht-mengsel vormen.

Fire Fighting Instructions

De aan gevaar blootgestelde tanks met watersproeistraal koelen.

Firefighter Protection Equipment

Ontploffings- en brandgassen niet inademen. Adembeschermingsapparaat dragen dat niet afhankelijk is van de omgevingslucht.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Ph
Not available
Partition Coefficient
Not available
Appearance
Not available
Dynamic Viscosity
Not available
Solubility In Water
niet resp. gering mengbaar
Melting Point
niet bepaald
Critical Property
Flammability
Not available
Cloud Point
Not available
Relative Evaporation Rate
Not available
Physical State Data
aerosol
Bulk Density
Not available
Odor
karakteristiek
Colour Intensity
Not available
Relative Density
Not available
Odor Threshold
Not available
Molecular Weight
Not available
Crystallisation Point
Not available
Metal Corrosion
Not available
Upper Explosive Limit
9,0 Vol %
Evaporation Rate
Not available
Vapor Density
Not available
Kinematic Viscosity
Not available
Voc Content
294g/l VOC
Colour
bruin
Density
niet bepaald
Critical Property
Softening Point
Not available
Physical State
Aërosol
Critical Property
Explosive Limits
Not available
Lower Explosive Limit
0,8 Vol %
State Under Standard Conditions
Not available
Solubility In Fat
Not available
Vapor Pressure
Not available
Decomposition Temperature
Not available
Freezing Point
niet bepaald
Solidification Point
Not available
Flash Point
Vanwege aerosol niet bruikbaar
Critical Property
Form
Aërosol
Solubility
niet resp. gering mengbaar
Boiling Point
Vanwege aerosol niet bruikbaar
Critical Property
Properties Status
Not available
Auto Ignition Temperature
Het produkt is niet uit zichzelf ontbrandend.
Handling & Storage

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

Handling Precautions

Voor goede ventilatie/afzuiging op de arbeidsplaatsen zorgen.

Tanks voorzichtig openen en behandelen.

Storage Conditions

Op een koele plaats bewaren.

De overheidsbepalingen m.

b.

t.

de opslag van drukgaspakkingen moeten in acht genomen worden.

Koel en droog bewaren in goed gesloten vaten.

Tegen hitte en directe zonnestralen beschermen.

Fire Prevention Measures

Onststekingsbronnen op afstand houden - niet roken. Maatregelen treffen tegen ontlading van statische elektriciteit. Attentie: De tank staat onder druk. Beschermen tegen directe zonbestaling en temperaturen boven 50 °C. Zelfs na het verbruik niet met geweld openen of verbranden. Niet in open vuur of op gloeiende voorwerpen sproeien.

Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Hand Protection

Veiligheidshandschoenen. Het handschoenmateriaal moet ondoorlatend en bestand zijn tegen het product / de stof / de bereiding. Op grond van falende testen kan geen aanbeveling voor handschoenmateriaal voor het product / de bereiding / het chemicaliënmengsel afgegeven worden. Kies handschoenmateriaal rekening houdend met de penetratietijden, de permeatiegraden en de degradatie. Draag geschikte handschoenen getest volgens EN 374 Nitrielrubber (0.35 mm) De keuze van een geschikte handschoen is niet alleen afhankelijk van het materiaal, maar ook van andere kwaliteitskenmerken en verschilt van fabrikant tot fabrikant. Aangezien het product uit meerdere stoffen is samengesteld, is de duurzaamheid van de handschoenmaterialen niet vooraf berekenbaar en moet derhalve vóór het gebruik worden getest. Waarde voor de permeatie: Level ≤ 480 De precieze penetratietijd kunt u te weten komen bij de handschoenfabrikant; houd er rekening mee.

Eye Protection

Niet noodzakelijk.

Respiratory Protection

Alleen bij spuiten zonder voldoende afzuiging. Filter AX.

Skin/Body Protection

Draag geschikte beschermende arbeidskleding.

Section 10

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

Chemical Stability

Geen ontleding bij gebruik volgens voorschrift.

Reactivity

Geen verdere relevante informatie verkrijgbaar.

Hazardous Reactions

Geen gevaarlijke reacties bekend.

Conditions to Avoid

Warmte. Hete oppervlakken. Ontstekingsbronnen.Vlammen

Incompatible Materials

Sterke zuren en oxydatiemiddelen. Alkaliën (logen). sterk mineraalzuur

Hazardous Decomposition Products

Bij verhitting of brand is het ontstaan van vergiftige gassen mogelijk. Koolmonoxyde en kooldioxyde

Section 13

Waste Disposal & Treatment Methods

Waste disposal procedures, treatment methods, and regulatory compliance requirements

Product Disposal Recommendations

Mag niet tesamen met huisvuil gestort worden of in de riolering komen.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

1950

Proper Shipping Name

SPUITBUSSEN

ADR Transport Precautions

Waarschuwing: Gassen

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Cut and Drill Fluid 2?

The signal word for this substance is "danger".

What is the physical form of Cut and Drill Fluid 2?

Cut and Drill Fluid 2 is a aërosol with bruin color. It has karakteristiek odor.

What is the solubility of Cut and Drill Fluid 2?

niet resp. gering mengbaar

What is Cut and Drill Fluid 2 used for?

Smeerolie

What are the hazard statements for Cut and Drill Fluid 2?

This substance has 5 hazard statements: H222: Zeer licht ontvlambare aerosol. H229: Houder onder druk: kan open barsten bij verhitting. H336: Kan slaperigheid of duizeligheid veroorzaken. H362: Kan schadelijk zijn via borstvoeding. H411: Giftig voor in het water levende organismen, met langdurige gevolgen.

What is the melting point of Cut and Drill Fluid 2?

The melting point is niet bepaald and the boiling point is Vanwege aerosol niet bruikbaar.