NextSDS Logo
Fi

Fix ALL Turbo

NO SIGNAL WORD Vast SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Fix ALL Turbo
Product Form
Mengsel

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Consumentengebruik,Professioneel gebruik,Afdichtingsmiddelen
Uses Advised Against
Geen aanvullende informatie beschikbaar

Overview

Fix ALL Turbo is a pasta-achtig. substance commonly used consumentengebruik,professioneel gebruik,afdichtingsmiddelen.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

Hazard Classifications

Not Classified

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Soudal (UK) Ltd company logo - Safety Data Sheet supplier organization

Soudal (UK) Ltd

distributor

Soudal House, Unit 1, Centurion Way B77 5PN Centurion Park Tamworth

GB

+44 1827 261 092

Soudal N.V. company logo - Safety Data Sheet supplier organization

Soudal N.V.

undefined

Everdongenlaan 18-20 2300 Turnhout

BE

+32 14 42 42 31

+32 14 42 65 14

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Centre Anti-Poisons/Antigifcentrum

+32 70 245 245

BE

24/7

Alle dringende vragen over vergiftigingen: 070 245 245 (gratis), of indien onbereikbaar tel. 02 264 96 30 (normaal tarief).

Centre Anti-Poisons/Antigifcentrum

02 264 96 30

BE

indien onbereikbaar tel. 02 264 96 30 (normaal tarief).

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
N/A N/A 1-5% Hazardous
trimethoxyvinylsilaan
EC: 220-449-8
2768-02-7 1% Hazardous
3-(trimethoxysilyl)propylamine
EC: 237-511-5
13822-56-5 1-5% Hazardous

Additional Information

Volledige tekst van H- en EUH-zinnen: zie sectie 16

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

De persoon in de frisse lucht brengen en ervoor zorgen dat deze gemakkelijk kan ademen. Bij ademhalingsproblemen: arts/medische dienst raadplegen.

Skin Contact

Huid met water afspoelen/afdouchen. Bij huidirritatie of uitslag: een arts raadplegen.

Eye Contact

Als voorzorgsmaatregel de ogen met water uitspoelen. Contactlenzen verwijderen, indien mogelijk. Blijven spoelen. Indien de irritatie aanhoudt, een oogarts raadplegen.

Ingestion/Swallowing

Mond met water spoelen. Bij onwel voelen een arts raadplegen.

Immediate Medical Attention Required

Symptomatische behandeling.

Medical Treatment

Symptomatische behandeling.

Fire Safety

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

Suitable Extinguishing Media

Verneveld water. Droog poeder. Schuim. Koolstofdioxide.

Unsuitable Extinguishing Media

Geen enkele bekend.

Fire Fighting Instructions

Niet ingrijpen zonder geschikte veiligheidsmiddelen.

Firefighter Protection Equipment

Niet ingrijpen zonder geschikte veiligheidsmiddelen. Onafhankelijk werkend ademhalingsapparaat. Volledig beschermende kleding.

Spill Response

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

Emergency Procedures

Verontreinigde omgeving ventileren.

Large Spill Procedures

Grote hoeveelheden vrijgekomen stoffen: gemorste vaste stoffen opscheppen en in afsluitbare vaten deponeren.

Environmental Precautions

Voorkom lozing in het milieu.

Cleanup Methods

Verontreinigde oppervlakken reinigen met overvloedig water. Na werkzaamheden kleding en materiaal reinigen.

Cleanup Materials:

overvloedig water

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Appearance
Pasta-achtig.
Lower Explosive Limit
Niet van toepassing
Colour
Variabele.
Crystallisation Point
Not available
Relative Evaporation Rate
Not available
Odor
karakteristiek.
Boiling Point
Niet beschikbaar
Critical Property
Odor Threshold
Niet beschikbaar
Solubility
Niet beschikbaar
Physical State
Vast
Critical Property
Bulk Density
Not available
Solubility In Fat
Not available
Properties Status
Not available
Dynamic Viscosity
Not available
Metal Corrosion
Not available
Melting Point
Niet van toepassing
Critical Property
Physical State Data
solid
Density
1,505 g/cm³ (20°C)
Critical Property
Cloud Point
Not available
Form
Not available
Flash Point
> 100 °C
Critical Property
Freezing Point
Niet beschikbaar
Solidification Point
Not available
Relative Density
1,505 (20°C)
Vapor Pressure
Niet beschikbaar
Colour Intensity
Not available
Explosive Limits
Not available
Softening Point
Not available
State Under Standard Conditions
Not available
Auto Ignition Temperature
Niet van toepassing
Molecular Weight
Not available
Solubility In Water
Not available
Evaporation Rate
Not available
Ph
Niet beschikbaar
Kinematic Viscosity
Niet van toepassing
Voc Content
< 1 %
Upper Explosive Limit
Niet van toepassing
Vapor Density
Not available
Decomposition Temperature
Niet beschikbaar
Flammability
Niet van toepassing
Partition Coefficient
Niet beschikbaar
Handling & Storage

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

Handling Precautions

Zorg voor een goede ventilatie van de werkplek.

Draag een persoonlijke beschermingsuitrusting.

Storage Conditions

Bewaren bij kamertemperatuur.

Op een goed geventileerde plaats bewaren.

De vaten gesloten houden als ze niet worden gebruikt.

General Hygiene Measures

Niet eten, drinken of roken tijdens het gebruik van dit product. Na hantering van dit product altijd handen wassen.

Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Zorg voor een goede ventilatie van de werkplek.

Hand Protection

Beschermende handschoenen

Eye Protection

Veiligheidsbril

Respiratory Protection

Bij ontoereikende ventilatie een geschikt ademhalingsapparaat gebruiken

Skin/Body Protection

Draag geschikte beschermende kleding

Environmental Exposure Controls

Voorkom lozing in het milieu.

Section 10

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

Chemical Stability

Stabiel onder normale omstandigheden.

Reactivity

Het product is onder normale gebruiks-, opslag- en transportcondities niet reactief.

Hazardous Reactions

Geen gevaarlijke reacties bekend onder normale gebruiksomstandigheden.

Conditions to Avoid

Geen onder aanbevolen opslag- en hanteringscondities (zie lid 7).

Incompatible Materials

Geen aanvullende informatie beschikbaar

Hazardous Decomposition Products

Onder normale opslag- en gebruiksvoorwaarden zullen er geen gevaarlijke ontledingsproducten ontstaan.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

Niet gereglementeerd

Proper Shipping Name

Niet gereglementeerd

Transport Hazard Class

Niet gereglementeerd

Packing Group

Niet gereglementeerd

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Fix ALL Turbo?

The signal word for this substance is "no signal word".

What is the physical form of Fix ALL Turbo?

Fix ALL Turbo is a vast appearing as pasta-achtig. with variabele. color. It has karakteristiek. odor.

What is the solubility of Fix ALL Turbo?

Niet beschikbaar

What is Fix ALL Turbo used for?

Consumentengebruik,Professioneel gebruik,Afdichtingsmiddelen

What is the melting point of Fix ALL Turbo?

The melting point is Niet van toepassing and the boiling point is Niet beschikbaar.