Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
AdBlue
Product Form
Mengsel
Product Code
06.30.31

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Reactant voor het verminderen van NOx-emissies.

Uses advised against

Geen aanvullende informatie beschikbaar

Manufacturers & Suppliers

K

Kroon-Oil BV B.V.

manufacturer

Dollegoorweg, 15, NL-7602 EC Almelo, Nederland

0031 (0)546 81 81 65

Emergency Contacts

Centre Anti-Poisons/Antigifcentrum c/o Hôpital Militaire Reine Astrid

+32 70 245 245

Nationaal Vergiftigingen Informatie Centrum

+31 88 755 80 00

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Urea EC: 200-315-5 57-13-6 25 - 50% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

De persoon in de frisse lucht brengen en ervoor zorgen dat deze gemakkelijk kan ademen.

Skin contact

De huid met overvloedig water wassen.

Eye contact

Als voorzorgsmaatregel de ogen met water uitspoelen.

Ingestion

Bij onwel voelen een antigifcentrum of een arts raadplegen.

Medical Treatment

Symptomatische behandeling.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Verneveld water. Droog poeder. Schuim. Koolstofdioxide.

Unsuitable media

Gebruik geen sterke waterstraal.

Firefighter Protection

Niet ingrijpen zonder geschikte veiligheidsmiddelen. Onafhankelijk werkend ademhalingsapparaat. Volledig beschermende kleding.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Verontreinigde omgeving ventileren.

Environmental

Voorkom lozing in het milieu.

Cleanup methods

Gemorste vloeistof absorberen met een absorptiemiddel.

Materials: absorptiemiddel

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Zorg voor een goede ventilatie van de werkplek. Draag een persoonlijke beschermingsuitrusting.

Storage

Op een goed geventileerde plaats bewaren. Koel bewaren.

Hygiene

Niet eten, drinken of roken tijdens het gebruik van dit product. Na hantering van dit product altijd handen wassen.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Zorg voor een goede ventilatie van de werkplek.

Hands

Beschermende handschoenen. Type: Herbruikbare handschoenen, Materiaal: Nitrilrubber (NBR), permeatie: 6 (> 480 minuten), Dikte (mm): ≥0.35, Norm: EN ISO 374

Eyes

Veiligheidsbril. Type: Veiligheidsbril, Toepassingsgebied: Druppeltjes, Kenmerken: helder, Norm: EN 166

Respiratory

Bij ontoereikende ventilatie een geschikt ademhalingsapparaat gebruiken

Skin/Body

Draag geschikte beschermende kleding

Environmental

Voorkom lozing in het milieu.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Colour
Kleurloos tot lichtgeel.
Flash Point
> 100 °C
Cloud Point
---
Solubility In Fat
---
State Under Standard Conditions
---
Voc Content
0 %
Relative Density
Niet beschikbaar
Odor Threshold
Niet beschikbaar
Metal Corrosion
---
Vapor Density
---
Solidification Point
---
Melting Point
-11 °C
Physical State Data
liquid
Vapor Pressure
---
Dynamic Viscosity
---
Kinematic Viscosity
Niet beschikbaar
Solubility In Water
---
Colour Intensity
---
Decomposition Temperature
60 °C Geen ontleding bij gebruik volgens de voorschriften
Boiling Point
103 °C
Form
---
Crystallisation Point
---
Molecular Weight
---
Ph
8,5 – 10
Upper Explosive Limit
Niet beschikbaar
Physical State
Vloeibaar
Appearance
helder.
Density
1,09 g/cm³
Lower Explosive Limit
Niet beschikbaar
Flammability
Niet van toepassing
Partition Coefficient
Niet beschikbaar
Solubility
Water: Oplosbaar
Explosive Limits
---
Softening Point
---
Auto Ignition Temperature
Niet beschikbaar
Evaporation Rate
---
Properties Status
---
Bulk Density
---
Relative Evaporation Rate
---
Odor
karakteristiek.
Freezing Point
-11 °C
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stabiel onder normale omstandigheden.

Reactivity

Het product is onder normale gebruiks-, opslag- en transportcondities niet reactief.

Hazardous reactions

Geen gevaarlijke reacties bekend onder normale gebruiksomstandigheden.

Avoid

Geen onder aanbevolen opslag- en hanteringscondities (zie lid 7).

Incompatible

Geen aanvullende informatie beschikbaar

Decomposition

Onder normale opslag- en gebruiksvoorwaarden zullen er geen gevaarlijke ontledingsproducten ontstaan.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for AdBlue?

The signal word is no signal word.

What is the physical form of AdBlue?

AdBlue is a vloeibaar appearing as helder. with kleurloos tot lichtgeel. color. It has karakteristiek. odor.

What is the solubility of AdBlue?

Water: Oplosbaar

What is AdBlue used for?

Reactant voor het verminderen van NOx-emissies.

What is the melting point of AdBlue?

The melting point is -11 °C and the boiling point is 103 °C.

Compliance Scanner