NextSDS Logo
Tr

Transbond™M LR Light Cure Adhesive

WARNING Solid. SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Transbond™M LR Light Cure Adhesive
Product Code
712-038

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Orthodontic use

Overview

Transbond™M LR Light Cure Adhesive is a paste substance commonly used orthodontic use.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (WARNING!)

Hazard Classifications

Skin Sens. Category 1 H317

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H317: May cause an allergic skin reaction.

Precautionary Statements

  • P261: Avoid breathing dust/fume/gas/mist/vapours/spray.
  • P272: Contaminated work clothing should not be allowed out of the workplace.
  • P302 + P352: IF ON SKIN: Wash with plenty of soap and water.
  • P333 + P313: If skin irritation or rash occurs: Get medical advice/attention.
  • P363: Wash contaminated clothing before reuse.
  • P501: Dispose of contents/container in accordance with applicable local/regional/national/international regulations.
  • Wear protective gloves.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

3M Australia company logo - Safety Data Sheet supplier organization

3M Australia

manufacturer

📍

Building A, 1 Rivett Road, North Ryde NSW 2113

🌍

AU

📞

136 136

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

📞

1800 097 146

🌍

AU

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
2-Propenoic acid, 2-methyl-, 3- (trimethoxysilyl)propyl ester, reaction products with quartz, bulk material
EC: 309-515-8
100402-78-6 75-85% ✓ Non-hazardous
Bisphenol A Diglycidyl Ether Dimethacrylate
EC: 216-367-7
1565-94-2 5-15% ✓ Non-hazardous
Triethylene Glycol Dimethacrylate
EC: 203-652-6
109-16-0 Not specified ✓ Non-hazardous
Dichlorodimethylsilane Reaction Product with Silica
EC: 271-893-4
68611-44-9 Not specified ✓ Non-hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Remove person to fresh air. If you feel unwell, get medical attention.

🖐️ Skin Contact

Immediately wash with soap and water. Remove contaminated clothing and wash before reuse. If signs/symptoms develop, get medical attention.

👁️ Eye Contact

Flush with large amounts of water. Remove contact lenses if easy to do. Continue rinsing. If signs/symptoms persist, get medical attention.

🍽️ Ingestion/Swallowing

Rinse mouth. If you feel unwell, get medical attention.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

📊 Auto Ignition Temperature
No data available.
🧪 Physical State
Solid.
Critical Property
🔥 Flash Point
No flash point
Critical Property
📊 Partition Coefficient
No data available.
📊 Solidification Point
Not available
📊 Odor Threshold
No data available.
📊 Freezing Point
Not available
🧪 Ph
Not applicable.
🔥 Flammability
Not classified
📊 Upper Explosive Limit
Not applicable.
📊 Solubility In Water
Not available
📊 Solubility In Fat
Not available
💧 Solubility
Not available
📊 Form
Not available
📊 Bulk Density
Not available
📊 Properties Status
Not available
📊 Relative Evaporation Rate
Not available
💨 Evaporation Rate
Not applicable.
📊 Colour Intensity
Not available
📊 State Under Standard Conditions
Not available
📊 Decomposition Temperature
No data available.
📊 Crystallisation Point
Not available
📊 Softening Point
Not available
📊 Lower Explosive Limit
Not applicable.
💨 Boiling Point
Not applicable.
Critical Property
📊 Explosive Limits
Not available
📊 Vapor Density
Not available
📊 Dynamic Viscosity
Not available
🧊 Melting Point
No data available.
Critical Property
🎨 Colour
Off-White
⚖️ Density
No data available.
Critical Property
📊 Relative Density
Approximately 1.95 [Ref Std: WATER=1]
👁️ Appearance
Paste
📊 Voc Content
No data available.
📊 Metal Corrosion
Not available
💨 Vapor Pressure
Not applicable.
👃 Odor
Slight Acrylate
📊 Kinematic Viscosity
Not applicable.
📊 Cloud Point
Not available
📊 Physical State Data
solid
📊 Molecular Weight
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Use in a well-ventilated area.

🧤 Hand Protection

See Section 7.1 for additional information on skin protection.

👁️ Eye Protection

Select and use eye/face protection to prevent contact based on the results of an exposure assessment. The following eye/face protection(s) are recommended: Safety glasses with side shields. Select and use eye protection in accordance with AS/NZS 1336. Eye protection should comply with the performance specifications of AS/NZS 1337.

😷 Respiratory Protection

None required.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Transbond™M LR Light Cure Adhesive?

The signal word for this substance is "warning".

What is the physical form of Transbond™M LR Light Cure Adhesive?

Transbond™M LR Light Cure Adhesive is a solid. appearing as paste with off-white color. It has slight acrylate odor.

What is Transbond™M LR Light Cure Adhesive used for?

Orthodontic use

What are the hazard statements for Transbond™M LR Light Cure Adhesive?

This substance has 1 hazard statements: H317: May cause an allergic skin reaction.

What is the melting point of Transbond™M LR Light Cure Adhesive?

The melting point is No data available. and the boiling point is Not applicable..