NextSDS Logo
Br

Britesil C20

NO SIGNAL WORD SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Britesil C20

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Detergent industry - raw material; Water- and waste water treatment - process chemical; Refractory industry - raw material

Overview

Britesil C20 is a fine, hygroscopic granules (mean particle size: 80 -900 micrometer) substance commonly used detergent industry - raw material; water- and waste water treatment - process chemical; refractory industry - raw material.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

Hazard Classifications

Eye Dam. Category 1
STOT SE Category 3
Skin Irrit. Category 2

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

PQ Europe

undefined

PQ Nederland B.V.

undefined

๐Ÿ“

Ankerkade 111 6222 NL Maastricht

๐ŸŒ

NL

๐Ÿ“ 

+31 43 3525955

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

PQ Europe

๐Ÿ“ž

+31 43 3525959

๐ŸŒ

NL

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

General Composition

Sodium silicate in powder and granular form, 1,6 < molar ratio 2,6

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Sodium silicate, 1,6 < molar ratio 2,6
EC: 215-687-4
1344-09-8 80% โš ๏ธ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Move to fresh air, rest, half upright position, loosen clothing. Seek medical advice if irritation develops.

Symptoms:

Irritating to respiratory system.

๐Ÿ–๏ธ Skin Contact

Remove immediately all contaminated clothing. Wash immediately with plenty of water. Seek medical advice if irritation develops.

Symptoms:

Irritating to skin.

๐Ÿ‘๏ธ Eye Contact

Thoroughly rinse immediately with plenty of water for 15 minutes. Eyelids should be held away from the eyeball to ensure thorough rinsing. Ophthalmic treatment necessary.

Symptoms:

Causes injury to the cornea and eyelids. Risk of serious damage to eyes.

๐Ÿฝ๏ธ Ingestion/Swallowing

Only when conscious, rinse mouth, give plenty of water to drink. Do not induce vomiting. Seek medical advice.

๐Ÿšจ Immediate Medical Attention Required

Ophthalmic treatment necessary.

Medical Treatment

Ophthalmic treatment necessary.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Bulk Density
400 - 900 kg/m
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ‘ƒ Odor
odourless
๐Ÿ“Š Form
granules
โš–๏ธ Density
not determined
Critical Property
๐Ÿ“Š Partition Coefficient
not applicable
๐Ÿ”ฅ Flammability
not applicable
๐Ÿ’จ Boiling Point
not applicable
Critical Property
๐Ÿ“Š Dynamic Viscosity
Not available
๐ŸŽจ Colour
white
๐Ÿงช Physical State
Not available
๐Ÿ“Š Physical State Data
solid
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ“Š Solubility In Water
partly soluble
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Freezing Point
Not available
๐Ÿ’จ Vapor Pressure
not applicable
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ‘๏ธ Appearance
Fine, hygroscopic granules (Mean particle size: 80 -900 micrometer)
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Relative Density
Not available
๐ŸงŠ Melting Point
not determined
Critical Property
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ”ฅ Flash Point
non combustible
Critical Property
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Odor Threshold
Not available
๐Ÿ“Š Properties Status
Not available
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ’ง Solubility
Not available
๐Ÿงช Ph
11,2 - 11,9 (1% solution)
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Auto Ignition Temperature
non combustible

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Working areas and methods should be organized in such a way that direct contact is avoided. Avoid dust generation. Areas in which handling generates dust should have adequate ventilation equipment to minimize exposure to personnel.

๐Ÿงค Hand Protection

Wear chemical or alkali resistant protective gloves (according to EN 374, cat. III).

๐Ÿ‘๏ธ Eye Protection

Wear basket eye glasses or a face protection shield.

๐Ÿ˜ท Respiratory Protection

In case of dust formation use suitable respiratory equipment. (respirator with filter P2).

๐Ÿฆบ Skin/Body Protection

Wear suitable protective clothing.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Britesil C20?

The signal word for this substance is "no signal word".

What is Britesil C20 used for?

Detergent industry - raw material; Water- and waste water treatment - process chemical; Refractory industry - raw material

What is the melting point of Britesil C20?

The melting point is not determined and the boiling point is not applicable.