NextSDS Logo
Safety Data Sheet EN

Ilation paste E-COLL

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Ilation paste E-COLL
Product Form
paste
Product Code
4317784015417, 4317784348935

Regulatory Identifiers

CAS Number
N/A

Identified Uses

SU21 Consumer uses: Private households / general public / consumers, SU22 Professional uses: Public domain (administration, education, entertainment, services, craftsmen), Application of the substance / the mixture Lubricant

Manufacturers & Suppliers

E

E/D/E - Einkaufsbuero Deutscher Eisenhaendler GmbH

manufacturer

EDE Platz 1, D-42389 Wuppertal, Germany

+49 202 6096-0

Emergency Contacts

Giftinformationszentrum Mainz

+49 (6131) 19240

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture of substances listed below with nonhazardous additions.

For the wording of the listed risk phrases refer to section 16.

Notes

Dangerous components: Void

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of complaints. Supply fresh air.

Eye contact

Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.

Ingestion

Rinse out mouth and then drink plenty of water. Drink plenty of water and provide fresh air. Call for a doctor immediately.

Immediate Medical Attention

Call for a doctor immediately.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use fire extinguishing methods suitable to surrounding conditions.

Specific hazards

Formation of toxic gases is possible during heating or in case of fire.

Firefighter Protection

No special measures required.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Not required.

Environmental

Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Send for recovery or disposal in suitable receptacles.

Materials: suitable receptacles

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

No special precautions are necessary if used correctly.

Storage

No special requirements.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see item 7.

Hands

Not required. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

Respiratory

Not necessary if room is well-ventilated.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Colour
Copper coloured
Freezing Point
---
Appearance
---
Odor
Characteristic
Evaporation Rate
Not applicable.
Colour Intensity
---
Voc Content
0,00 %
Kinematic Viscosity
Not applicable.
Form
Solid
Explosive Limits
---
Vapor Pressure
Not applicable.
Ph
Not applicable.
Properties Status
---
Melting Point
Undetermined.
Metal Corrosion
---
Decomposition Temperature
Not determined.
Flammability
Not determined.
Boiling Point
> 360 °C
Odor Threshold
Not determined.
Physical State
Solid
Physical State Data
solid
Softening Point
---
Solidification Point
---
Solubility In Fat
---
Density
Not determined.
Solubility
---
Molecular Weight
---
Relative Density
Not determined.
Lower Explosive Limit
Not determined.
Partition Coefficient
Not determined.
Dynamic Viscosity
Not applicable.
Upper Explosive Limit
Not determined.
Auto Ignition Temperature
>350 °C
Solubility In Water
Insoluble.
Crystallisation Point
---
Vapor Density
Not applicable.
Relative Evaporation Rate
---
State Under Standard Conditions
---
Cloud Point
---
Bulk Density
---
Flash Point
200 °C
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Hazardous reactions

Forms heat. Reacts with strong oxidizing agents.

Avoid

No further relevant information available.

Incompatible

No further relevant information available.

Decomposition

No dangerous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Containers can be recycled if completely empty; if not, dispose product/containers as dangerous waste. Observe local regulations.

Disposal

Completely emptied packagings can be given for recycling. (In accordance with local authority regulations, take to chemical/physical treatment plant.)

Waste Codes

07 06 99 wastes not otherwise specified EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
Void
Shipping Name
Void
Transport Class
Void
Packing Group
Void
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

A Chemical Safety Assessment has not been carried out.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Ilation paste E-COLL?

The signal word is no signal word.

What is the physical form of Ilation paste E-COLL?

Ilation paste E-COLL is a solid with copper coloured color. It has characteristic odor.

What is Ilation paste E-COLL used for?

SU21 Consumer uses: Private households / general public / consumers, SU22 Professional uses: Public domain (administration, education, entertainment, services, craftsmen), Application of the substance / the mixture Lubricant

What is the melting point of Ilation paste E-COLL?

The melting point is Undetermined. and the boiling point is > 360 °C.

Compliance Scanner

Scan your compliance