Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Unique Formula Identifier - for poison centres and emergency response
Uses Information
Overview
AlCr commonly used metallurgical industry, additive to casting alloy.
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
GHS Hazard Pictograms & Safety Symbols
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
Precautionary Statements
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
Alumetal Poland Sp. z o. o. Zakad Gorzyce
national supplier
ul. Odlewnikw 52, 39-432 Gorzyce, Poland
PL
+48 15 644 94 00
+48 15 644 94 01
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
producer
+48 15644 94 00
PL
7:00 15:00
emergency centre
112
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
mixtureGeneral Composition
The product is a mixture alloy of aluminium and chromium
Chemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Aluminium EC: 231-072-3 | 7429-90-5 | 78-96% | โ Non-hazardous |
| Chromium EC: 231-157-5 | 7440-47-3 | 4-22% | โ Non-hazardous |
Composition Notes
The classification of hazardous substances contained in the product is given in Table 3 of Annex VI to the Regulation of the European Parliament and Council Regulation (EC) No 1272/2008 including its amends, REACH data, the manufacturer and available literature data.
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
๐ซ Inhalation Exposure
Move victim to fresh air. If symptoms persist, consult a doctor. If breathing is difficult, give oxygen, in the absence of breath use artificial respiration. Seek medical advice immediately.
Symptoms:
Symptoms persist, difficulty breathing.
๐๏ธ Skin Contact
In case of burns immediately cool the skin, apply dressing contact with doctor. In case of skin injury by sharp edges, clean, disinfect and dress the wound, if necessary, contact with doctor. In the case of persistent irritation consult a dermatologist.
Symptoms:
Burns, skin injury by sharp edges, persistent irritation.
๐๏ธ Eye Contact
Immediately rinse eyes with running water with wide-open eyelids a continuous stream of water for about 10 minutes. In the case of persistent irritation consult an ophthalmologist.
Symptoms:
Eye irritation by fumes or dust arising from the treatment.
๐จ Immediate Medical Attention Required
Immediately contact doctor in the event of health problems. Seek medical advice immediately for inhalation exposure.
Medical Treatment
No specific antidote, treat symptomatically.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
๐ญ Engineering Controls
Use engineering controls to reduce air contamination to permissible exposure level. Explosion-proof general and local exhaust ventilation. Monitor exposure and apply all possible technical measures to ensure the maintenance of the concentrations of hazardous products in the workplace below recommended exposure limits.
๐งค Hand Protection
Recommended protective gloves. Relevant standards include EN ISO 21420:2020, EN ISO 374-1:2017/A1:2018, EN ISO 374-2:2020, EN 16523-1:2015+A1:2018, EN 407:2020.
๐๏ธ Eye Protection
Safety glasses in a sealed cover (goggles) (e.g. EN 166). Relevant standards include EN ISO 16321-1:2022, EN ISO 16321-3:2022, EN ISO 4007:2018.
๐ท Respiratory Protection
Not necessary under normal conditions with sufficient ventilation, required during exposure to high concentrations of dust. Wear mask or respirator completed with the antidust filter. Relevant standards include EN 140:1999/AC:2000, EN 143:2021, EN 149:2001+A1:2009.
๐ฆบ Skin/Body Protection
Protective, working clothing. Body protection must be chosen depending on activity and possible exposure (according to EN ISO 13982 in case of dust). Relevant standards include EN ISO 13688:2013, EN 14605:2005+A1:2009, EN ISO 20345:2022.
๐ Environmental Exposure Controls
Do not allow to enter large amounts of product into ground water, sewage, waste water or soil.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for AlCr?
The signal word for this substance is "no signal word".
What is the physical form of AlCr?
AlCr is a solid, bars with grey color. It has no odor.
What is the solubility of AlCr?
insoluble in water
What is AlCr used for?
Metallurgical industry, additive to casting alloy
What is the melting point of AlCr?
The melting point is not determined and the boiling point is does not apply.