NextSDS Logo
AR

ARCAL Chrome

WARNING Gas. SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
ARCAL Chrome
Product Code
300-15-001ALBNL-ARC

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Industrial and professional uses. Perform risk assessment prior to use. Contact supplier for more information on uses. Industrial and professional use for chemical analysis, calibration, (routine) quality control, laboratory use, under controlled conditions.
Uses Advised Against
Consumer use. Uses other than those listed above are not supported, contact your supplier for more information on other uses.

Overview

ARCAL Chrome commonly used industrial and professional uses. perform risk assessment prior to use. contact supplier for more information on uses. industrial and professional use for chemical analysis, calibration, (routine) quality control, laboratory use, under controlled conditions..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Gases under pressure H280

GHS Hazard Pictograms & Safety Symbols

GHS04 GHS Hazard Pictogram: Compressed gas hazard - Pressurized gases that may explode if heated

GHS04

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H280: Contains gas under pressure; may explode if heated.

Precautionary Statements

  • P403: Store in a well-ventilated place.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

AIR LIQUIDE BV company logo - Safety Data Sheet supplier organization

AIR LIQUIDE BV

national supplier

๐Ÿ“

De Witbogt 1 5652 AG Eindhoven the Netherlands-Nederland

๐ŸŒ

NL

๐Ÿ“ž

+31 (0)40 250 35 03

L'AIR LIQUIDE BELGE S.A./N.V. company logo - Safety Data Sheet supplier organization

L'AIR LIQUIDE BELGE S.A./N.V.

national supplier

๐Ÿ“

Hermeslaan 11 1932 Zaventem Belgium-Belgique-Belgi

๐ŸŒ

BE

๐Ÿ“ž

+32 (0)2 540 86 60

L'AIR LIQUIDE LUXEMBOURG S.A. company logo - Safety Data Sheet supplier organization

L'AIR LIQUIDE LUXEMBOURG S.A.

national supplier

๐Ÿ“

ZONE P.E.D .- B.P.20 L-4801 RODANGE Luxemburg

๐ŸŒ

LU

๐Ÿ“ž

+352 26 30 29 03

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Centre Anti-Poisons/Antigifcentrum c/o Hpital Militaire Reine Astrid

๐Ÿ“ž

+32 70 245 245

๐ŸŒ

BE

๐Ÿ•’

24/7

๐Ÿ’ก

Please dial: 070 245 245 for any urgent questions about intoxication (free of charge 24/7), if not accessible, dial: 02 264 96 30 (standard fee)

Centre Anti-Poisons/Antigifcentrum c/o Hpital Militaire Reine Astrid

๐Ÿ“ž

02 264 96 30

๐ŸŒ

BE

๐Ÿ’ก

if not accessible, dial: 02 264 96 30 (standard fee)

Centre Anti-Poisons/Antigifcentrum c/o Hpital Militaire Reine Astrid

๐Ÿ“ž

+352 8002 5500

๐ŸŒ

LU

๐Ÿ•’

24/7 access

๐Ÿ—ฃ๏ธ

Languages: FR, NL, EN

๐Ÿ’ก

Free telephone number with a 24/7 access. Experts answer all urgency questions on dangerous products in French, Dutch and English

Nationaal Vergiftigingen Informatie Centrum

๐Ÿ“ž

+31 88 755 80 00

๐ŸŒ

NL

๐Ÿ•’

24 hours a day, 7 days a week

๐Ÿ’ก

Only for the purpose of informing medical personnel in cases of acute intoxications (24 hours a day, 7 days a week)

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Contains no other components or impurities which will influence the classification of the product.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Argon (diep gekoeld)
EC: 231-147-0
7440-37-1 Not specified โš ๏ธ Hazardous
CARBON DIOXIDE AEROSOL PROPELLANT substance with national workplace exposure limit(s) (GB); substance with a Community workplace exposure limit
EC: 204-696-9
124-38-9 Not specified โš ๏ธ Hazardous

Additional Information

*1: Listed in Annex IV / V REACH, exempted from registration. *3: Registration not required: Substance manufactured or imported < 1t/y.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Allow affected person to breathe fresh air. Allow the victim to rest. Remove victim to uncontaminated area wearing self contained breathing apparatus. Keep victim warm and rested. Call a doctor. Perform cardiopulmonary resuscitation if breathing stopped.

Symptoms:

In high concentrations may cause asphyxiation. Symptoms may include loss of mobility/consciousness. Victim may not be aware of asphyxiation.

๐Ÿ–๏ธ Skin Contact

Remove affected clothing and wash all exposed skin area with mild soap and water, followed by warm water rinse.

Symptoms:

Adverse effects not expected from this product.

๐Ÿ‘๏ธ Eye Contact

Rinse immediately with plenty of water. Obtain medical attention if pain, blinking or redness persists.

Symptoms:

Adverse effects not expected from this product.

๐Ÿฝ๏ธ Ingestion/Swallowing

Rinse mouth. Do NOT induce vomiting. Obtain emergency medical attention.

Symptoms:

Ingestion is not considered a potential route of exposure.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Gas.
Critical Property
๐Ÿ“Š Physical State Data
gas
๐Ÿ“Š State Under Standard Conditions
Gas.
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Colourless.
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
characteristic.
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
Not applicable for gases and gas mixtures.
๐ŸงŠ Melting Point
Not applicable for gas mixtures.
Critical Property
๐Ÿ’จ Boiling Point
Not applicable for gas mixtures. It is technically not possible to determine the boiling point or range of this mixture. Component with lowest boiling point: Argon -186
Critical Property
๐Ÿ”ฅ Flash Point
Not applicable for gases and gas mixtures.
Critical Property
๐Ÿ“Š Freezing Point
Not applicable for gas mixtures.
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not applicable for gases and gas mixtures.
๐Ÿ’จ Vapor Pressure
Not applicable.
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not applicable for gases and gas mixtures.
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not applicable for gases and gas mixtures.
Critical Property
๐Ÿ”ฅ Flammability
Non flammable.
๐Ÿ“Š Upper Explosive Limit
Not applicable.
๐Ÿ“Š Lower Explosive Limit
Not applicable.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Non flammable.
๐Ÿ“Š Decomposition Temperature
Not applicable.
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not applicable for gas mixtures.
๐Ÿ“Š Solubility In Water
No reliable data available.
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not applicable for gas mixtures.
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
No reliable data available.
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Provide adequate general and local exhaust ventilation. Systems under pressure should be regularily checked for leakages. Ensure exposure is below occupational exposure limits (where available). Oxygen detectors should be used when asphyxiating gases may be released. Consider the use of a work permit system e.g. for maintenance activities.

๐Ÿงค Hand Protection

Wear protective gloves. Wear working gloves when handling gas containers. Standard EN 388 - Protective gloves against mechanical risks, performance level 1 or higher. Recommended types include wrist gloves from leather or synthetic material with equivalent performance, fabric gloves, fabric gloves with leather palms.

๐Ÿ‘๏ธ Eye Protection

A risk assessment should be conducted and documented in each work area to assess the risks related to the use of the product and to select the PPE that matches the relevant risk. The following recommendations should be considered: PPE compliant to the recommended EN/ISO standards should be selected. : Wear safety glasses with side shields. Chemical goggles or safety glasses. Standard EN 166 - Personal eye-protection - specifications.

๐Ÿ˜ท Respiratory Protection

Gas filters may be used if all surrounding conditions e.g. type and concentration of the contaminant(s) and duration of use are known. Wear appropriate mask. Use gas filters with full face mask, where exposure limits may be exceeded for a short-term period, e.g. connecting or disconnecting containers. Standard EN 137 - Self-contained open-circuit compressed air breathing apparatus with full face mask. Consult respiratory device supplier's product information for the selection of the appropriate device. When indicated by a risk assessment, Respiratory Protective Equipment must be used. The selection of the Respiratory Protective Device (RPD) must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected RPD. Gas filters do not protect against oxygen deficiency. Self contained breathing apparatus (SCBA) or positive pressure airline with mask are to be used in oxygen-deficient atmospheres. Standard EN 14387 - Gas filter(s), combined filter(s) and standard EN136, full face masks . Self contained breathing apparatus is recommended, where unknown exposure may be expected, e.g. during maintenance activities on installation systems.

๐Ÿฆบ Skin/Body Protection

Wear safety shoes while handling containers. Standard EN ISO 20345 - Personal protective equipment - Safety footwear.

๐ŸŒ Environmental Exposure Controls

None necessary.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

1956

๐Ÿ“ฆ Proper Shipping Name

COMPRESSED GAS, N.O.S. (Argon, Carbon dioxide)

โš ๏ธ Transport Hazard Class

2

๐Ÿš› ADR Transport Precautions

Avoid transport on vehicles where the load space is not separated from the driver's compartment. Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency. Before transporting product containers: - Ensure there is adequate ventilation. - Ensure that containers are firmly secured. - Ensure valve is closed and not leaking. - Ensure valve outlet cap nut or plug (where provided) is correctly fitted. - Ensure valve protection device (where provided) is correctly fitted.

๐Ÿšข IMDG Maritime Transport Precautions

Avoid transport on vehicles where the load space is not separated from the driver's compartment. Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency. Before transporting product containers: - Ensure there is adequate ventilation. - Ensure that containers are firmly secured. - Ensure valve is closed and not leaking. - Ensure valve outlet cap nut or plug (where provided) is correctly fitted. - Ensure valve protection device (where provided) is correctly fitted.

โœˆ๏ธ IATA Air Transport Precautions

Avoid transport on vehicles where the load space is not separated from the driver's compartment. Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency. Before transporting product containers: - Ensure there is adequate ventilation. - Ensure that containers are firmly secured. - Ensure valve is closed and not leaking. - Ensure valve outlet cap nut or plug (where provided) is correctly fitted. - Ensure valve protection device (where provided) is correctly fitted.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for ARCAL Chrome?

The signal word for this substance is "warning".

What is the physical form of ARCAL Chrome?

ARCAL Chrome is a gas. with colourless. color. It has characteristic. odor.

What is ARCAL Chrome used for?

Industrial and professional uses. Perform risk assessment prior to use. Contact supplier for more information on uses. Industrial and professional use for chemical analysis, calibration, (routine) quality control, laboratory use, under controlled conditions.

What are the hazard statements for ARCAL Chrome?

This substance has 1 hazard statements: H280: Contains gas under pressure; may explode if heated.

What is the melting point of ARCAL Chrome?

The melting point is Not applicable for gas mixtures. and the boiling point is Not applicable for gas mixtures. It is technically not possible to determine the boiling point or range of this mixture. Component with lowest boiling point: Argon -186.