Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- ARCAL Chrome
- Product Code
- 300-15-001ALBNL-ARC
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Industrial and professional uses. Perform risk assessment prior to use. Contact supplier for more information on uses. Industrial and professional use for chemical analysis, calibration, (routine) quality control, laboratory use, under controlled conditions.
Uses advised against
Consumer use. Uses other than those listed above are not supported, contact your supplier for more information on other uses.
Manufacturers & Suppliers
AIR LIQUIDE BV
national supplier
De Witbogt 1 5652 AG Eindhoven the Netherlands-Nederland
+31 (0)40 250 35 03
www.airliquide-benelux.com
L'AIR LIQUIDE BELGE S.A./N.V.
national supplier
Hermeslaan 11 1932 Zaventem Belgium-Belgique-Belgi
+32 (0)2 540 86 60
www.airliquide-benelux.com
L'AIR LIQUIDE LUXEMBOURG S.A.
national supplier
ZONE P.E.D .- B.P.20 L-4801 RODANGE Luxemburg
+352 26 30 29 03
www.airliquide-benelux.com
Emergency Contacts
Centre Anti-Poisons/Antigifcentrum c/o Hpital Militaire Reine Astrid
+32 70 245 245
24/7
Centre Anti-Poisons/Antigifcentrum c/o Hpital Militaire Reine Astrid
02 264 96 30
Centre Anti-Poisons/Antigifcentrum c/o Hpital Militaire Reine Astrid
+352 8002 5500
24/7 access
FR, NL, EN
Nationaal Vergiftigingen Informatie Centrum
+31 88 755 80 00
24 hours a day, 7 days a week
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS04
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Contains no other components or impurities which will influence the classification of the product.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| N/A | --- | --- | Yes |
| N/A | --- | --- | Yes |
*1: Listed in Annex IV / V REACH, exempted from registration. *3: Registration not required: Substance manufactured or imported < 1t/y.
First Aid Measures
Emergency procedures for chemical exposure incidents
Allow affected person to breathe fresh air. Allow the victim to rest. Remove victim to uncontaminated area wearing self contained breathing apparatus. Keep victim warm and rested. Call a doctor. Perform cardiopulmonary resuscitation if breathing stopped.
Symptoms: In high concentrations may cause asphyxiation. Symptoms may include loss of mobility/consciousness. Victim may not be aware of asphyxiation.
Remove affected clothing and wash all exposed skin area with mild soap and water, followed by warm water rinse.
Symptoms: Adverse effects not expected from this product.
Rinse immediately with plenty of water. Obtain medical attention if pain, blinking or redness persists.
Symptoms: Adverse effects not expected from this product.
Rinse mouth. Do NOT induce vomiting. Obtain emergency medical attention.
Symptoms: Ingestion is not considered a potential route of exposure.
Related Substances
Similar chemicals with comparable safety profiles
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide adequate general and local exhaust ventilation. Systems under pressure should be regularily checked for leakages. Ensure exposure is below occupational exposure limits (where available). Oxygen detectors should be used when asphyxiating gases may be released. Consider the use of a work permit system e.g. for maintenance activities.
Wear protective gloves. Wear working gloves when handling gas containers. Standard EN 388 - Protective gloves against mechanical risks, performance level 1 or higher. Recommended types include wrist gloves from leather or synthetic material with equivalent performance, fabric gloves, fabric gloves with leather palms.
A risk assessment should be conducted and documented in each work area to assess the risks related to the use of the product and to select the PPE that matches the relevant risk. The following recommendations should be considered: PPE compliant to the recommended EN/ISO standards should be selected. : Wear safety glasses with side shields. Chemical goggles or safety glasses. Standard EN 166 - Personal eye-protection - specifications.
Gas filters may be used if all surrounding conditions e.g. type and concentration of the contaminant(s) and duration of use are known. Wear appropriate mask. Use gas filters with full face mask, where exposure limits may be exceeded for a short-term period, e.g. connecting or disconnecting containers. Standard EN 137 - Self-contained open-circuit compressed air breathing apparatus with full face mask. Consult respiratory device supplier's product information for the selection of the appropriate device. When indicated by a risk assessment, Respiratory Protective Equipment must be used. The selection of the Respiratory Protective Device (RPD) must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected RPD. Gas filters do not protect against oxygen deficiency. Self contained breathing apparatus (SCBA) or positive pressure airline with mask are to be used in oxygen-deficient atmospheres. Standard EN 14387 - Gas filter(s), combined filter(s) and standard EN136, full face masks . Self contained breathing apparatus is recommended, where unknown exposure may be expected, e.g. during maintenance activities on installation systems.
Wear safety shoes while handling containers. Standard EN ISO 20345 - Personal protective equipment - Safety footwear.
None necessary.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1956
- Shipping Name
- COMPRESSED GAS, N.O.S. (Argon, Carbon dioxide)
- Transport Class
- 2
Avoid transport on vehicles where the load space is not separated from the driver's compartment. Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency. Before transporting product containers: - Ensure there is adequate ventilation. - Ensure that containers are firmly secured. - Ensure valve is closed and not leaking. - Ensure valve outlet cap nut or plug (where provided) is correctly fitted. - Ensure valve protection device (where provided) is correctly fitted.
Avoid transport on vehicles where the load space is not separated from the driver's compartment. Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency. Before transporting product containers: - Ensure there is adequate ventilation. - Ensure that containers are firmly secured. - Ensure valve is closed and not leaking. - Ensure valve outlet cap nut or plug (where provided) is correctly fitted. - Ensure valve protection device (where provided) is correctly fitted.
Avoid transport on vehicles where the load space is not separated from the driver's compartment. Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency. Before transporting product containers: - Ensure there is adequate ventilation. - Ensure that containers are firmly secured. - Ensure valve is closed and not leaking. - Ensure valve outlet cap nut or plug (where provided) is correctly fitted. - Ensure valve protection device (where provided) is correctly fitted.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for ARCAL Chrome?
The signal word is warning.
What is the physical form of ARCAL Chrome?
ARCAL Chrome is a gas. with colourless. color. It has characteristic. odor.
What is ARCAL Chrome used for?
Industrial and professional uses. Perform risk assessment prior to use. Contact supplier for more information on uses. Industrial and professional use for chemical analysis, calibration, (routine) quality control, laboratory use, under controlled conditions.
What are the hazard statements for ARCAL Chrome?
This substance has 1 hazard statement:
- H280: Contains gas under pressure; may explode if heated.
What is the melting point of ARCAL Chrome?
The melting point is Not applicable for gas mixtures. and the boiling point is Not applicable for gas mixtures. It is technically not possible to determine the boiling point or range of this mixture. Component with lowest boiling point: Argon -186.