NextSDS Logo
Safety Data Sheet EN

ARCAL Chrome

How compliant is your chemical safety?

Free 2-minute compliance assessment

Check Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
ARCAL Chrome
Product Code
300-15-001ALBNL-ARC

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Industrial and professional uses. Perform risk assessment prior to use. Contact supplier for more information on uses. Industrial and professional use for chemical analysis, calibration, (routine) quality control, laboratory use, under controlled conditions.

Uses advised against

Consumer use. Uses other than those listed above are not supported, contact your supplier for more information on other uses.

Manufacturers & Suppliers

AIR LIQUIDE BV logo

AIR LIQUIDE BV

national supplier

De Witbogt 1 5652 AG Eindhoven the Netherlands-Nederland

+31 (0)40 250 35 03

www.airliquide-benelux.com

L'AIR LIQUIDE BELGE S.A./N.V. logo

L'AIR LIQUIDE BELGE S.A./N.V.

national supplier

Hermeslaan 11 1932 Zaventem Belgium-Belgique-Belgi

+32 (0)2 540 86 60

www.airliquide-benelux.com

L'AIR LIQUIDE LUXEMBOURG S.A. logo

L'AIR LIQUIDE LUXEMBOURG S.A.

national supplier

ZONE P.E.D .- B.P.20 L-4801 RODANGE Luxemburg

+352 26 30 29 03

www.airliquide-benelux.com

Emergency Contacts

Centre Anti-Poisons/Antigifcentrum c/o Hpital Militaire Reine Astrid

+32 70 245 245

24/7

Centre Anti-Poisons/Antigifcentrum c/o Hpital Militaire Reine Astrid

02 264 96 30

Centre Anti-Poisons/Antigifcentrum c/o Hpital Militaire Reine Astrid

+352 8002 5500

24/7 access

FR, NL, EN

Nationaal Vergiftigingen Informatie Centrum

+31 88 755 80 00

24 hours a day, 7 days a week

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Gases under pressure H280

GHS Pictograms

GHS04 - Compressed gas

GHS04

Hazard Statements

H280 Contains gas under pressure; may explode if heated.

Precautionary Statements

P403 Store in a well-ventilated place.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Contains no other components or impurities which will influence the classification of the product.

Chemical Name CAS Number Concentration Hazardous
N/A --- --- Yes
N/A --- --- Yes

*1: Listed in Annex IV / V REACH, exempted from registration. *3: Registration not required: Substance manufactured or imported < 1t/y.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Allow affected person to breathe fresh air. Allow the victim to rest. Remove victim to uncontaminated area wearing self contained breathing apparatus. Keep victim warm and rested. Call a doctor. Perform cardiopulmonary resuscitation if breathing stopped.

Symptoms: In high concentrations may cause asphyxiation. Symptoms may include loss of mobility/consciousness. Victim may not be aware of asphyxiation.

Skin contact

Remove affected clothing and wash all exposed skin area with mild soap and water, followed by warm water rinse.

Symptoms: Adverse effects not expected from this product.

Eye contact

Rinse immediately with plenty of water. Obtain medical attention if pain, blinking or redness persists.

Symptoms: Adverse effects not expected from this product.

Ingestion

Rinse mouth. Do NOT induce vomiting. Obtain emergency medical attention.

Symptoms: Ingestion is not considered a potential route of exposure.

Related Substances

Similar chemicals with comparable safety profiles

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Provide adequate general and local exhaust ventilation. Systems under pressure should be regularily checked for leakages. Ensure exposure is below occupational exposure limits (where available). Oxygen detectors should be used when asphyxiating gases may be released. Consider the use of a work permit system e.g. for maintenance activities.

Hands

Wear protective gloves. Wear working gloves when handling gas containers. Standard EN 388 - Protective gloves against mechanical risks, performance level 1 or higher. Recommended types include wrist gloves from leather or synthetic material with equivalent performance, fabric gloves, fabric gloves with leather palms.

Eyes

A risk assessment should be conducted and documented in each work area to assess the risks related to the use of the product and to select the PPE that matches the relevant risk. The following recommendations should be considered: PPE compliant to the recommended EN/ISO standards should be selected. : Wear safety glasses with side shields. Chemical goggles or safety glasses. Standard EN 166 - Personal eye-protection - specifications.

Respiratory

Gas filters may be used if all surrounding conditions e.g. type and concentration of the contaminant(s) and duration of use are known. Wear appropriate mask. Use gas filters with full face mask, where exposure limits may be exceeded for a short-term period, e.g. connecting or disconnecting containers. Standard EN 137 - Self-contained open-circuit compressed air breathing apparatus with full face mask. Consult respiratory device supplier's product information for the selection of the appropriate device. When indicated by a risk assessment, Respiratory Protective Equipment must be used. The selection of the Respiratory Protective Device (RPD) must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected RPD. Gas filters do not protect against oxygen deficiency. Self contained breathing apparatus (SCBA) or positive pressure airline with mask are to be used in oxygen-deficient atmospheres. Standard EN 14387 - Gas filter(s), combined filter(s) and standard EN136, full face masks . Self contained breathing apparatus is recommended, where unknown exposure may be expected, e.g. during maintenance activities on installation systems.

Skin/Body

Wear safety shoes while handling containers. Standard EN ISO 20345 - Personal protective equipment - Safety footwear.

Environmental

None necessary.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Gas.
Physical State Data
gas
State Under Standard Conditions
Gas.
Appearance
---
Colour
Colourless.
Colour Intensity
---
Form
---
Odor
characteristic.
Odor Threshold
---
Ph
Not applicable for gases and gas mixtures.
Melting Point
Not applicable for gas mixtures.
Boiling Point
Not applicable for gas mixtures. It is technically not possible to determine the boiling point or range of this mixture. Component with lowest boiling point: Argon -186
Flash Point
Not applicable for gases and gas mixtures.
Freezing Point
Not applicable for gas mixtures.
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not applicable for gases and gas mixtures.
Vapor Pressure
Not applicable.
Vapor Density
---
Relative Density
Not applicable for gases and gas mixtures.
Bulk Density
---
Density
Not applicable for gases and gas mixtures.
Flammability
Non flammable.
Upper Explosive Limit
Not applicable.
Lower Explosive Limit
Not applicable.
Explosive Limits
---
Auto Ignition Temperature
Non flammable.
Decomposition Temperature
Not applicable.
Solubility
---
Partition Coefficient
Not applicable for gas mixtures.
Solubility In Water
No reliable data available.
Solubility In Fat
---
Molecular Weight
Not applicable for gas mixtures.
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
No reliable data available.
Properties Status
---
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1956
Shipping Name
COMPRESSED GAS, N.O.S. (Argon, Carbon dioxide)
Transport Class
2
ADR

Avoid transport on vehicles where the load space is not separated from the driver's compartment. Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency. Before transporting product containers: - Ensure there is adequate ventilation. - Ensure that containers are firmly secured. - Ensure valve is closed and not leaking. - Ensure valve outlet cap nut or plug (where provided) is correctly fitted. - Ensure valve protection device (where provided) is correctly fitted.

IMDG

Avoid transport on vehicles where the load space is not separated from the driver's compartment. Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency. Before transporting product containers: - Ensure there is adequate ventilation. - Ensure that containers are firmly secured. - Ensure valve is closed and not leaking. - Ensure valve outlet cap nut or plug (where provided) is correctly fitted. - Ensure valve protection device (where provided) is correctly fitted.

IATA

Avoid transport on vehicles where the load space is not separated from the driver's compartment. Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency. Before transporting product containers: - Ensure there is adequate ventilation. - Ensure that containers are firmly secured. - Ensure valve is closed and not leaking. - Ensure valve outlet cap nut or plug (where provided) is correctly fitted. - Ensure valve protection device (where provided) is correctly fitted.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for ARCAL Chrome?

The signal word is warning.

What is the physical form of ARCAL Chrome?

ARCAL Chrome is a gas. with colourless. color. It has characteristic. odor.

What is ARCAL Chrome used for?

Industrial and professional uses. Perform risk assessment prior to use. Contact supplier for more information on uses. Industrial and professional use for chemical analysis, calibration, (routine) quality control, laboratory use, under controlled conditions.

What are the hazard statements for ARCAL Chrome?

This substance has 1 hazard statement:

  • H280: Contains gas under pressure; may explode if heated.

What is the melting point of ARCAL Chrome?

The melting point is Not applicable for gas mixtures. and the boiling point is Not applicable for gas mixtures. It is technically not possible to determine the boiling point or range of this mixture. Component with lowest boiling point: Argon -186.

Compliance Scan