NextSDS Logo
Gl

Glycerin Glycerin

NO SIGNAL WORD viscous SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Glycerin Glycerin
Product Code
G2289
Chemical Name
Glycerin
Synonyms
Glycerin

Regulatory Identifiers

CAS Number

Chemical Abstracts Service registry number - unique identifier for chemical substances

EC Number

European Community number - used for regulatory compliance in EU/EEA

Uses Information

Identified Uses
Laboratory chemicals, Manufacture of substances

Overview

Glycerin Glycerin (CAS: 56-81-5 ) commonly used laboratory chemicals, manufacture of substances.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Sigma-Aldrich Chemie GmbH

undefined

๐Ÿ“

Eschenstrasse 5 D-82024 TAUFKIRCHEN

๐ŸŒ

DE

๐Ÿ“ž

+49 (0)89 6513-1130

๐Ÿ“ 

+49 (0)89 6513-1161

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

CHEMTREC Deutschland

๐Ÿ“ž

0800 181 7059

๐ŸŒ

DE

CHEMTREC weltweit

๐Ÿ“ž

+49 (0)696 43508409

๐ŸŒ

DE

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Glycerin
EC: 200-289-5
56-81-5 Not specified โœ“ Non-hazardous

Composition Notes

No components need to be disclosed according to the applicable regulations.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

If breathed in, move person into fresh air. If not breathing, give artificial respiration.

๐Ÿ–๏ธ Skin Contact

Wash off with soap and plenty of water.

๐Ÿ‘๏ธ Eye Contact

Flush eyes with water as a precaution.

๐Ÿฝ๏ธ Ingestion/Swallowing

Never give anything by mouth to an unconscious person. Rinse mouth with water.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐ŸงŠ Melting Point
Melting point/range: 20 - lit.
Critical Property
๐Ÿ“Š Properties Status
Not available
๐Ÿ“Š Lower Explosive Limit
2,7 %(V) at 1013 hPa
๐Ÿ‘๏ธ Appearance
Not available
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Solubility In Water
miscible
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
5,5 - 8
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ“Š Partition Coefficient
log Pow: - 1,75 at 25
๐Ÿ‘ƒ Odor
odorless
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Upper Explosive Limit
19 %(V) at 1013 hPa
๐Ÿ”ฅ Flammability
No data available
๐ŸŽจ Colour
clear
โš–๏ธ Density
1,25 g/cm3 - lit.
Critical Property
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Physical State Data
Not available
๐Ÿ”ฅ Flash Point
199 at ca.1013,0 hPa - Pensky-Martens closed cup
Critical Property
๐Ÿ“Š Bulk Density
Not available
๐Ÿ“Š Form
Not available
๐Ÿงช Physical State
viscous
Critical Property
๐Ÿ’จ Vapor Pressure
0,004 hPa at 50 0,260 hPa at 100 C 5,7 hPa at 150
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Auto Ignition Temperature
370
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ“Š Relative Density
No data available
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Dynamic Viscosity
No data available
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Kinematic Viscosity
No data available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Decomposition Temperature
No data available
๐Ÿ“Š Softening Point
Not available
๐Ÿ’จ Boiling Point
182 at 27 hPa - lit.
Critical Property

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿงค Hand Protection

Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it. Full contact Material: Nitrile rubber Minimum layer thickness: 0,11 mm Break through time: 480 min Material tested: Dermatril (KCL 740 / Aldrich Z677272, Size M) Splash contact Material: Nitrile rubber Minimum layer thickness: 0,11 mm Break through time: 480 min Material tested: Dermatril (KCL 740 / Aldrich Z677272, Size M) data source: KCL GmbH, D-36124 Eichenzell, phone +49 (0)6659 87300, e-mail [email protected], test method: EN374 If used in solution, or mixed with other substances, and under conditions which differ from EN 374, contact the supplier of the EC approved gloves. This recommendation is advisory only and must be evaluated by an industrial hygienist and safety officer familiar with the specific situation of anticipated use by our customers. It should not be construed as offering an approval for any specific use scenario.

๐Ÿ‘๏ธ Eye Protection

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).

๐Ÿ˜ท Respiratory Protection

Respiratory protection not required. For nuisance exposures use type OV/AG (US) or type ABEK (EU EN 14387) respirator cartridges. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).

๐Ÿฆบ Skin/Body Protection

Impervious clothing, The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.

๐ŸŒ Environmental Exposure Controls

No special environmental precautions required.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿ“ฆ Proper Shipping Name

Not dangerous goods

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What other names is Glycerin Glycerin known by?

Glycerin Glycerin is also known as: Glycerin

What is the hazard signal word for Glycerin Glycerin?

The signal word for this substance is "no signal word".

What is the physical form of Glycerin Glycerin?

Glycerin Glycerin is a viscous with clear color. It has odorless odor.

What is Glycerin Glycerin used for?

Laboratory chemicals, Manufacture of substances

What is the melting point of Glycerin Glycerin?

The melting point is Melting point/range: 20 - lit. and the boiling point is 182 at 27 hPa - lit..