Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
Xpert Omni MTB/RIF Ultra is a beads are solid white components in cartridges; reagents are clear liquids which are primarily buffered in aqueous solutions. components are odorless. substance commonly used laboratory use.
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS02
GHS05
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
- H226: Flammable liquid and vapour
- H314: Causes severe skin burns and eye damage.
- H318: Causes serious eye damage
- Suspected of causing genetic defects.
- Suspected of damaging fertility or the unborn child.
- May cause damage to organs through prolonged or repeated exposure.
Precautionary Statements
- P210: Keep away from heat, sparks, open flames and/or hot surfaces. - No smoking.
- P233: Keep container tightly closed.
- P260: Do not breathe mists, vapours, and/or spray.
- P264: Wash thoroughly after handling.
- P280: Wear protective gloves/protective clothing/eye protection/face protection.
- P301+P330+P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
- P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower.
- P304+P340: IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing.
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P310: Immediately call a POISON CENTER or doctor/physician.
- P321: Specific treatment, see supplemental first aid information.
- P363: Wash contaminated clothing before reuse.
- P370+P378: In case of fire: Use appropriate media for extinction.
- P501: Dispose of content and/or container in accordance with local, regional, national, and/or international regulations.
- Obtain special instructions before use.
- Do not handle until all safety precautions have been read and understood.
- Use personal protective equipment as required.
- IF exposed or concerned: Get medical advice/attention.
- Get medical advice/attention if you feel unwell.
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
Cepheid
manufacturer
904 Caribbean Drive Sunnyvale, CA 94089 United States
US
(888) 838-3222 - US Option 2; 1 (408) 541-4191 - Outside of the US
Cepheid AB
distributor
Rntgenvgen 5 SE-171 54 Solna Sweden
SE
+33 563 825 319 - EU
Cepheid India Private Limited
distributor
1, SIPCOT Industrial Growth Centre, Oragadam, Kanchipuram, Tamil Nadu - 602 105, India
IN
+91 11 48353010
Cepheid Holdings Pty Ltd
distributor
Suite 2, Level 3, Building A 11 Talavera Road Macquarie Park, NSW 2113 Australia
AU
1800 107 884
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
INFOTRAC
1 (800) 535-5053
US
24 hr Emergency
Emergency Contact
1 (352) 323-3500
US
Outside of the US
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
MixtureGeneral Composition
Material does not meet the criteria of a substance in accordance with Regulation (EC) No 1272/2008.
Chemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Isopropylique Alcohol EC: 200-661-7 | 67-63-0 | 10-15% | โ ๏ธ Hazardous |
| Sodium Hydroxide (NaOH) EC: 215-185-5 | 1310-73-2 | 5-8% | โ ๏ธ Hazardous |
Additional Information
Safety Data Sheet Effective Date: 2023-06 Supersedes: 2022-4 Xpert MTB/RIF Xpert MTB/RIF Ultra Xpert MTB/XDR Xpert Omni MTB/RIF Ultra
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
๐ซ Inhalation Exposure
Remove to fresh air. Administer oxygen if breathing is difficult. Give artificial respiration if victim is not breathing. If signs/symptoms continue, get medical attention.
๐๏ธ Skin Contact
Wash skin with soap and water. Get medical attention.
๐๏ธ Eye Contact
Hold eye open and rinse slowly and gently with water for 15-20 minutes. Remove contact lenses, if present, after the first five minutes, then continue rinsing eye. Get medical attention.
๐ฝ๏ธ Ingestion/Swallowing
Rinse mouth. Never give anything by mouth to an unconscious person. Get medical attention.
๐จ Immediate Medical Attention Required
All treatments should be based on observed signs and symptoms of distress in the patient.
Medical Treatment
All treatments should be based on observed signs and symptoms of distress in the patient.
Fire Fighting Measures & Emergency Response
Fire suppression methods, extinguishing media, and firefighting safety procedures
โ Suitable Extinguishing Media
Use water spray (fog), foam, dry powder, or carbon dioxide.
โ Unsuitable Extinguishing Media
No data available
โ ๏ธ Specific Fire Hazards
This material is classified flammable, however it is in small vials and is unlikely to cause significant flammability hazard in use.
๐ก๏ธ Firefighter Protection Equipment
Fire fighters should wear complete protective clothing including self-contained breathing apparatus.
Accidental Release Measures & Spill Response
Emergency spill cleanup procedures, containment methods, and environmental protection
๐จ Emergency Procedures
No emergency procedures are expected to be necessary if material is used under ordinary conditions as recommended.
๐ง Small Spill Procedures
For small spills, wear gloves and absorb spill with paper towel. Do not dispose spilled materials down drain.
๐ Environmental Precautions
Prevent entry into waterways, sewers, basements or confined areas.
๐งน Cleanup Methods
absorb spill with paper towel.
Cleanup Materials:
paper towel
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Safe Handling & Storage Procedures
Industrial handling precautions, storage conditions, and workplace safety requirements
โ ๏ธ Handling Precautions
โข Use good safety and industrial hygiene practices.
โข Use appropriate Personal Protective Equipment (PPE).
โข Avoid contact with skin and eyes.
๐ช Storage Conditions
โข Store according to product labeling.
๐งผ General Hygiene Measures
Wash thoroughly with soap and water after handling and before eating, drinking, or using tobacco.
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
๐ญ Engineering Controls
Good general ventilation should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level.
๐๏ธ Eye Protection
Wear chemical splash safety goggles.
๐ท Respiratory Protection
Follow the OSHA respirator regulations found in 29 CFR 1910.134 or European Standard EN 149. Use a NIOSH/MSHA or European Standard EN 149 approved respirator if exposure limits are exceeded or symptoms are experienced.
๐ฆบ Skin/Body Protection
Wear protective clothing
๐ Environmental Exposure Controls
Follow best practice for site management and disposal of waste.
Chemical Stability & Reactivity Data
Chemical stability, hazardous reactions, and incompatible materials information
โ Chemical Stability
Stable under normal temperatures and pressures.
โ๏ธ Reactivity
No dangerous reaction known under conditions of normal use.
โ ๏ธ Hazardous Reactions
Isopropyl alcohol may form explosive mixture in air. For all other ingredients, no potential for hazardous reactions identified.
๐ซ Conditions to Avoid
Heat, flames, sparks.
๐งช Incompatible Materials
Acids, oxidizing agents.
Ecological Information & Environmental Impact
Environmental toxicity, biodegradation, bioaccumulation, and ecological effects data
๐ฑ Toxicity
๐ฑ Persistence and Degradability
๐ฑ Bioaccumulative Potential
๐ฑ Mobility in Soil
๐ฑ Results of PBT and vPvB assessment
๐ฑ Other Adverse Effects
Waste Disposal & Treatment Methods
Waste disposal procedures, treatment methods, and regulatory compliance requirements
โป๏ธ Waste Treatment Methods
Dispose of content and/or container in accordance with local, regional, national, and/or international regulations.
๐๏ธ Product Disposal Recommendations
Dispose of content and/or container in accordance with local, regional, national, and/or international regulations.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
๐ท๏ธ UN Number
UN2920
๐ฆ Proper Shipping Name
Corrosive liquids, flammable, n.o.s. (sodium hydroxide, isopropanol)
โ ๏ธ Transport Hazard Class
8,3
๐ Packing Group
II
๐ข IMDG Maritime Transport Precautions
None specified.
โ๏ธ IATA Air Transport Precautions
None specified.
Regulatory Information & Compliance
Chemical regulations, safety assessments, and regulatory compliance status
โ Chemical Safety Assessment
No chemical safety assessment has been performed for this substance.
โน๏ธ Additional Regulatory Information
SARA Hazard Classifications Acute, Chronic, Fire
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for Xpert Omni MTB/RIF Ultra?
The signal word for this substance is "danger".
What is the physical form of Xpert Omni MTB/RIF Ultra?
Xpert Omni MTB/RIF Ultra is a liquid appearing as beads are solid white components in cartridges; reagents are clear liquids which are primarily buffered in aqueous solutions. components are odorless. with white/clear color. It has data lacking odor.
What is Xpert Omni MTB/RIF Ultra used for?
Laboratory use
What are the hazard statements for Xpert Omni MTB/RIF Ultra?
This substance has 6 hazard statements: H226: Flammable liquid and vapour H314: Causes severe skin burns and eye damage. H318: Causes serious eye damage Suspected of causing genetic defects. Suspected of damaging fertility or the unborn child. May cause damage to organs through prolonged or repeated exposure.
What is the melting point of Xpert Omni MTB/RIF Ultra?
The melting point is Data lacking and the boiling point is Data lacking.