Basic Product Information

Product Name
Injection Resin 86120
Product Code
86120

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Structural resins Adhesives

Overview

Injection Resin 86120 commonly used structural resins adhesives.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Eye Irrit. Category 2 H319
Skin Sens. Category 1 H317
Aquatic Chronic Category 3 H412

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H317: May cause an allergic skin reaction.
  • H319: Causes serious eye irritation.
  • H412: Harmful to aquatic life with long lasting effects.

Precautionary Statements

  • P272: Contaminated work clothing should not be allowed out of the workplace.
  • P280: Wear protective gloves / eye protection.
  • P302+P352: IF ON SKIN: Wash with plenty of soap and water.
  • P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
  • P403+P235: Store in a well-ventilated place. Keep cool.
  • P501: Dispose of contents/container in accordance with local/regional/national/international regulations.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

KENT (United Kingdom) Ltd

manufacturer

๐Ÿ“

Forsyth House Pitreavie Drive Pitreavie Business Park Dunfermline Fife KY11 8US

๐ŸŒ

GB

๐Ÿ“ž

0800 136925

๐Ÿ“ 

+44 1383 620079

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+44 01383 723344

๐ŸŒ

GB

๐Ÿ•’

During normal office hours - Monday - Thursday 8.30am - 5.30pm, Friday 9.00am - 3.00pm

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixture

General Composition

Mixture of the substances listed below with harmless additions.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
vinyltoluene
EC: 246-562-2
25013-15-4 1-10% โš ๏ธ Hazardous
Ethylvinylbenzene
EC: 248-846-1
28106-30-1 1-10% โš ๏ธ Hazardous
DIBENZOYL PEROXIDE
EC: 202-327-6
94-36-0 5% โš ๏ธ Hazardous
2-ethylhexyl benzoate
EC: 226-641-8
5444-75-7 5% โš ๏ธ Hazardous
Monoethyleenglycol, ethaan1,2-diol
EC: 203-473-3
107-21-1 5% โš ๏ธ Hazardous

Additional Information

For the wording of the listed hazard phrases refer to section 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Supply fresh air; consult doctor in case of symptoms.

๐Ÿ–๏ธ Skin Contact

Instantly wash with water and soap and rinse thoroughly. If skin irritation continues, consult a doctor.

๐Ÿ‘๏ธ Eye Contact

Rinse opened eye for several minutes under running water. Then consult doctor.

๐Ÿฝ๏ธ Ingestion/Swallowing

Do not induce vomiting; instantly call for medical help. Rinse out mouth and then drink plenty of water.

๐Ÿšจ Immediate Medical Attention Required

No further relevant information available.

Medical Treatment

No further relevant information available.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿ“Š Decomposition Temperature
Not determined.
๐Ÿงช Physical State
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Relative Density
Not determined.
๐Ÿ“Š Vapor Density
Not applicable.
๐Ÿ“Š Upper Explosive Limit
Not determined.
๐Ÿ“Š Solubility In Water
Unsoluble
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ”ฅ Flash Point
Not applicable
Critical Property
๐Ÿ“Š Bulk Density
Not available
๐Ÿ“Š Physical State Data
Not available
๐Ÿ“Š Voc Content
1.85g/l VOC
๐Ÿ“Š Auto Ignition Temperature
Not available
๐Ÿ’จ Evaporation Rate
Not applicable.
๐Ÿ“Š Kinematic Viscosity
Not applicable.
๐Ÿ“Š Solidification Point
Not available
๐Ÿ’จ Vapor Pressure
Not applicable.
๐Ÿ“Š Form
Pasty
๐ŸŽจ Colour
According to product specification
๐Ÿ“Š Properties Status
Not available
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ“Š Freezing Point
Not available
โš–๏ธ Density
Not determined
Critical Property
๐Ÿ‘๏ธ Appearance
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ‘ƒ Odor
Characteristic
๐Ÿ“Š Odor Threshold
Not determined.
๐Ÿ’จ Boiling Point
Not determined
Critical Property
๐Ÿ“Š Partition Coefficient
Not determined.
๐Ÿงช Ph
Not applicable.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Dynamic Viscosity
Not applicable.
๐Ÿ”ฅ Flammability
Not determined.
๐Ÿ“Š Lower Explosive Limit
Not determined.
๐Ÿ“Š Softening Point
Not available
๐ŸงŠ Melting Point
Not determined
Critical Property
๐Ÿ“Š Cloud Point
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Ensure good ventilation. If this is not sufficient breathing protection must be used so that the vaporisation level is held under the workplace limit. No further specific engineering controls detailed; see item 7.

๐Ÿงค Hand Protection

Protective gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: Nitrile rubber, NBR. Recommended thickness of the material: 0.5 mm. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Value for the permeation: Level 480 min (level 6). The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

๐Ÿ‘๏ธ Eye Protection

Safety glasses recommended during refilling.

๐Ÿ˜ท Respiratory Protection

Ensure good ventilation. If this is not sufficient breathing protection must be used so that the vaporisation level is held under the workplace limit. Filter to EN 141, Filter A.

๐Ÿฆบ Skin/Body Protection

Protective work clothing. (EN-13034/6)

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Injection Resin 86120?

The signal word for this substance is "warning".

What is Injection Resin 86120 used for?

Structural resins Adhesives

What are the hazard statements for Injection Resin 86120?

This substance has 3 hazard statements: H317: May cause an allergic skin reaction. H319: Causes serious eye irritation. H412: Harmful to aquatic life with long lasting effects.

What is the melting point of Injection Resin 86120?

The melting point is Not determined and the boiling point is Not determined.