MicroVue C1-Inhibitor Plus EIA kit is a clear liquid substance commonly used the microvue c1-inhibitor plus enzyme immunoassay (eia) measures the amount of functional c1-inhibitor protein in human plasma or serum. this kit is for in vitro diagnostic use..
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS07
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
- H315: Causes skin irritation.
- H317: May cause an allergic skin reaction.
- H319: Causes serious eye irritation.
- H319: Causes serious eye irritation.
- H336: May cause dizziness or drowsiness.
- H360: May damage fertility or the unborn child.
Precautionary Statements
- P264: Wash hands thoroughly after handling.
- P280: Wear protective gloves and safety glasses.
- P303 + P361 + P353: IF ON SKIN (or hair): Remove immediately all contaminated clothing. Rinse skin with water.
- P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P333 + P313: If skin irritation or rash occurs: Get medical attention.
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
Quidel Corporation
manufacturer
2005 East State Street, Suite 100 Athens, OH 45701
US
1.800.874.1517
1.740.592.9820
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Quidel Corporation
1.866.519.4752
US
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Chemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Chloorwaterstof EC: 231-595-7 | 7647-01-0 | 4% | โ Non-hazardous |
| Peroxyde d'hydrogene EC: 231-765-0 | 7722-84-1 | 0.1% | โ Non-hazardous |
| 1-Ethyl-2-Pyrrolidone (NEP) EC: 220-250-6 | 2687-91-4 | 1-5% | โ Non-hazardous |
| Dimethylketon EC: 200-662-2 | 67-64-1 | 1-10% | โ Non-hazardous |
| Mixture for Proclin 300: 5-Chloro-2-methyl-2,3-dihydroisothiazol-3-one; 2-Methyl-2,3-dihydroisothiazol-3-one (3:1) | 55965-84-9 | 0.035% | โ Non-hazardous |
| Mixture for Proclin 300: 5-Chloro-2-methyl-2,3-dihydroisothiazol-3-one; 2-Methyl-2,3-dihydroisothiazol-3-one (3:1) | 55965-84-9 | 0.035% | โ Non-hazardous |
| Mixture for Proclin 300: 5-Chloro-2-methyl-2,3-dihydroisothiazol-3-one; 2-Methyl-2,3-dihydroisothiazol-3-one (3:1) | 55965-84-9 | 0.035% | โ Non-hazardous |
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
๐ซ Inhalation Exposure
Move the person to fresh air and support breathing as required.
๐๏ธ Skin Contact
Wash affected area with soap and water. Seek medical advice if irritation develops.
Symptoms:
if irritation develops
๐๏ธ Eye Contact
Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists, get medical attention.
Symptoms:
If eye irritation persists
๐ฝ๏ธ Ingestion/Swallowing
Never give anything by mouth to an unconscious person. Rinse mouth with water (do not swallow). Seek medical advice if irritation develops.
Symptoms:
if irritation develops
Medical Treatment
Treat symptomatically.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
๐ญ Engineering Controls
Use with adequate ventilation.
๐งค Hand Protection
Handle with appropriately rated chemical resistant gloves. Gloves should be inspected prior to use. Use proper glove technique to remove gloves to avoid contact with skin. Wash hands after handling the components within this kit.
๐๏ธ Eye Protection
Wear safety glasses with side shields or goggles to prevent eye contact.
๐ท Respiratory Protection
None needed under normal conditions of use.
๐ฆบ Skin/Body Protection
Use body protection appropriate for the task. A laboratory coat is recommended.
๐ Environmental Exposure Controls
No special environmental controls are required.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for MicroVue C1-Inhibitor Plus EIA kit?
The signal word for this substance is "warning".
What is MicroVue C1-Inhibitor Plus EIA kit used for?
The MicroVue C1-Inhibitor Plus Enzyme Immunoassay (EIA) measures the amount of functional C1-Inhibitor protein in human plasma or serum. This kit is for In Vitro Diagnostic use.
What are the hazard statements for MicroVue C1-Inhibitor Plus EIA kit?
This substance has 6 hazard statements: H315: Causes skin irritation. H317: May cause an allergic skin reaction. H319: Causes serious eye irritation. H319: Causes serious eye irritation. H336: May cause dizziness or drowsiness. H360: May damage fertility or the unborn child.
What is the melting point of MicroVue C1-Inhibitor Plus EIA kit?
The melting point is No data available and the boiling point is No data available.