NextSDS Logo
EP

EP Curing Agent

DANGER liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
EP Curing Agent
Product Code
EX-920

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Hardener Industrial uses: Uses of substances as such or in preparations at industrial sites Professional uses: Public domain (administration, education, entertainment, services, craftsmen)
Uses Advised Against
Do not use for private purposes (household).

Overview

EP Curing Agent is a liquid transparent substance commonly used hardener industrial uses: uses of substances as such or in preparations at industrial sites professional uses: public domain (administration, education, entertainment, services, craftsmen).

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Eye Dam. Category 1 H318
Skin Irrit. Category 2 H315
Flam. Liq. Category 3 H226
STOT SE Category 3 H335
STOT RE Category 2 H373

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS05 GHS Hazard Pictogram: Corrosive hazard - Materials that can cause severe skin burns and eye damage

GHS05

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H226: Flammable liquid and vapour.
  • H315: Causes skin irritation.
  • H318: Causes serious eye damage.
  • H335: May cause respiratory irritation.
  • H373: May cause damage to organs through prolonged or repeated exposure.

Precautionary Statements

  • P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
  • P233: Keep container tightly closed.
  • P310: Immediately call a POISON CENTER/doctor/....
  • P321: Specific treatment (see ... on this label).
  • P403 + P235: Store in a well-ventilated place. Keep cool.
  • P405: Store locked up.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Geholit + Wiemer Lack- und Kunststoff-Chemie GmbH

manufacturer

๐Ÿ“

Sofienstrae 36, 76676 Graben-Neud

๐ŸŒ

DE

๐Ÿ“ž

+49 (0) 7255 / 990

๐Ÿ“ 

+49 (0) 7255 / 99123

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+49 (0) 7255 / 99299

๐ŸŒ

DE

๐Ÿ•’

Mo - Thu 7.00 - 17.00 Uhr Fr 7.00 - 15.30 Uhr Only available during office hours.

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixtures

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
4-nonylfenol-, vertakt
EC: 215-535-7
1330-20-7 20-25% โš ๏ธ Hazardous
BUTAN-1-OL
EC: 200-751-6
71-36-3 5-10% โš ๏ธ Hazardous
ETHYLENEDIAMINE
EC: 203-468-6
107-15-3 0.1-0.5% โš ๏ธ Hazardous

Additional Information

Full text of H- and EUH-phrases: see section 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Remove casualty to fresh air and keep warm and at rest. If breathing is irregular or stopped, administer artificial respiration. In case of respiratory tract irritation, consult a physician. Provide fresh air.

Symptoms:

respiratory tract irritation, Asthmatic complaints, Respiratory complaints, Dizziness, Headache

๐Ÿ–๏ธ Skin Contact

Remove contaminated, saturated clothing immediately. Wash immediately with: Water and soap. In case of skin irritation, consult a physician.

Symptoms:

skin irritation, Allergic reactions

๐Ÿ‘๏ธ Eye Contact

In case of contact with eyes flush immediately with plenty of flowing water for 10 to 15 minutes holding eyelids apart and consult an ophthalmologist.

๐Ÿฝ๏ธ Ingestion/Swallowing

Rinse mouth thoroughly with water. Let water be drunken in little sips (dilution effect).

Medical Treatment

Treat symptomatically.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
liquid transparent
๐ŸŽจ Colour
transparent
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
like: Amines
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
Not available
๐ŸงŠ Melting Point
Not available
๐Ÿ’จ Boiling Point
approx. 120 C
Critical Property
๐Ÿ”ฅ Flash Point
24 C ISO 3679:2015
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
approx. 44 hPa
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
0,9 - 1 g/cm[3]
Critical Property
๐Ÿ”ฅ Flammability
Not available
๐Ÿ“Š Upper Explosive Limit
12 Vol-%
๐Ÿ“Š Lower Explosive Limit
0,8 Vol-%
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
> 200 C
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not available
๐Ÿ“Š Solubility In Water
Not available
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
33,25 Wt %
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Technical exhaust or ventilation measures

๐Ÿงค Hand Protection

Work must be in accordance with EN 374. Please observe the permeation times. Gloves with shorter permeation times are only suitable for short term contact activities. Full contact gloves should offer permeation times over 120 minutes. Contaminated gloves should be disposed of immediately, specially flattered gloves or short term contact gloves should be disposed of after the end of the shift. Camatril made by KCL, or comparable products Material thickness > 0,4mm Permeation time > 30 minutes. Recommended for short term contact: nitrile-based rubber, e.g. Butoject made by KCL, or comparable products. Material thickness > 0,7mm Permeation time > 30 minutes. Recommended for short term contact: butyl-based rubber, e.g.

๐Ÿ‘๏ธ Eye Protection

Eye glasses with side protection DIN EN 166

๐Ÿ˜ท Respiratory Protection

If technical exhaust or ventilation measures are not possible or insufficient, respiratory protection must be worn. Respiratory protection necessary at: exceeding exposure limit values

๐Ÿฆบ Skin/Body Protection

Required properties antistatic material Natural fibres (e.g. cotton)

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

UN 1866

๐Ÿ“ฆ Proper Shipping Name

RESIN SOLUTION

๐Ÿ“‹ Packing Group

III

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for EP Curing Agent?

The signal word for this substance is "danger".

What is the physical form of EP Curing Agent?

EP Curing Agent is a liquid appearing as liquid transparent with transparent color. It has like: amines odor.

What is EP Curing Agent used for?

Hardener Industrial uses: Uses of substances as such or in preparations at industrial sites Professional uses: Public domain (administration, education, entertainment, services, craftsmen)

What are the hazard statements for EP Curing Agent?

This substance has 5 hazard statements: H226: Flammable liquid and vapour. H315: Causes skin irritation. H318: Causes serious eye damage. H335: May cause respiratory irritation. H373: May cause damage to organs through prolonged or repeated exposure.