Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Ultraschall-Koppelmittel ZGF

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Coupling gel

Uses advised against

None known.

Manufacturers & Suppliers

GE Sensing & Inspection Technologies GmbH logo

GE Sensing & Inspection Technologies GmbH

undefined

Robert-Bosch-Str. 3 50354 Hrth / GERMANY

+49 (0) 2233-601-0

www.ge-mcs.com

Emergency Contacts

GEC

+49 (0) 700-24112112

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

STOT RE Cat. 2 H373

GHS Pictograms

GHS08 - Serious health hazard

GHS08

Hazard Statements

H373 May cause damage to organs through prolonged or repeated exposure.

Precautionary Statements

P260 Do not breathe vapours.
P314 Get medical advice / attention if you feel unwell.
P501 Dispose of contents / container to in accordance with local / regional / national / international regulation.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Mono Ethylene Glycol EC: 203-473-3 107-21-1 12.5 - 20% Yes
Azotan(III) sodu EC: 231-555-9 7632-00-0 0.5% Yes

Notes

Substances of Very High Concern - SVHC: substances are not contained or are below 0.1%. For full text of H-statements and R-phrases: see SECTION 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Ensure supply of fresh air. In the event of symptoms seek for medical treatment.

Skin contact

In case of contact with skin wash off immediately with soap and water. Consult a doctor if skin irritation persists.

Eye contact

In case of contact with eyes rinse thoroughly and immediately with plenty of water and seek medical advice.

Ingestion

Rinse out mouth and give plenty of water to drink. Do not induce vomiting. Supply with medical care.

Symptoms: Gastro-intestinal complaints.

Immediate Medical Attention

Treat symptomatically. Forward this sheet to the doctor.

Medical Treatment

Treat symptomatically. Forward this sheet to the doctor.

Related Substances

Similar chemicals with comparable safety profiles

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
green
Colour Intensity
---
Form
liquid
Odor
characteristic
Odor Threshold
not determined
Ph
9
Melting Point
not determined
Boiling Point
100 [C]
Flash Point
not applicable
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
not determined
Vapor Pressure
16.49 mbar (20C)
Vapor Density
---
Relative Density
---
Bulk Density
not applicable
Density
1.00 (20C)
Flammability
not applicable
Upper Explosive Limit
not determined
Lower Explosive Limit
not determined
Explosive Limits
---
Auto Ignition Temperature
not determined
Decomposition Temperature
not determined
Solubility
---
Partition Coefficient
not determined
Solubility In Water
miscible
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Ultraschall-Koppelmittel ZGF?

The signal word is warning.

What is the physical form of Ultraschall-Koppelmittel ZGF?

Ultraschall-Koppelmittel ZGF is a liquid with green color. It has characteristic odor.

What is Ultraschall-Koppelmittel ZGF used for?

Coupling gel

What are the hazard statements for Ultraschall-Koppelmittel ZGF?

This substance has 1 hazard statement:

  • H373: May cause damage to organs through prolonged or repeated exposure.

What is the melting point of Ultraschall-Koppelmittel ZGF?

The melting point is not determined and the boiling point is 100 [C].

Compliance Scan

Free compliance check