NextSDS Logo
Safety Data Sheet EN

UNICUT MF-Spezial Frsen

How compliant is your chemical safety?

Free 2-minute compliance assessment

Check Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
UNICUT MF-Spezial Frsen
Product Code
37100

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Metal working lubricant for minimum lubrication

Manufacturers & Suppliers

UNICUT Wahl GmbH logo

UNICUT Wahl GmbH

manufacturer

Feld-Vorstmann-Str. 14 D-56170 Bendorf / Rh

www.unicut-wahl.de

Emergency Contacts

Emergency Contact

0049 (0) 2622 / 4266

Mon-Thu: 8.30 a.m. - 4:30 p.m Fri: 8:30 a.m. - 12:30 p.m.

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Aquatic Chronic Cat. 3 H412

GHS Pictograms

Hazard Statements

H412 Harmful to aquatic life with long lasting effects.

Precautionary Statements

P273 Avoid release to the environment.
P501 Dispose of contents/container in accordance with local/regional/national/international regulations.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Fatty alcohol derivates with AW-and EP-additves

Chemical Name CAS Number Concentration Hazardous
Talgalkylamin ethoxylat EC: 500-153-8 61791-26-2 0.1 - 0.5% Yes

For the wording of the listed hazard phrases refer to section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of complaints.

Skin contact

Immediately wash with water and soap and rinse thoroughly.

Eye contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

Ingestion

Do not induce vomiting; call for medical help immediately.

Immediate Medical Attention

No further relevant information available.

Related Substances

Similar chemicals with comparable safety profiles

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see item 7.

Hands

Oil resistant gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Nitrile rubber, NBR. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed. For the permanent contact gloves made of the following materials are suitable: Nitrile rubber, NBR.

Eyes

Goggles recommended during refilling

Respiratory

Not required.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Odor
Characteristic
Softening Point
---
Upper Explosive Limit
Not determined.
Lower Explosive Limit
Not determined.
Vapor Density
Not determined.
Properties Status
---
Physical State
Liquid
Boiling Point
324 C
Molecular Weight
---
Ph
Not determined.
Solubility In Water
Not miscible or difficult to mix.
Crystallisation Point
---
Odor Threshold
Not determined.
Density
0.85 g/cm
State Under Standard Conditions
---
Auto Ignition Temperature
Product is not selfigniting.
Colour
Dark yellow
Vapor Pressure
1 hPa
Decomposition Temperature
Not determined.
Solubility In Fat
---
Kinematic Viscosity
32 mm/s
Flammability
Not applicable.
Evaporation Rate
Not determined.
Colour Intensity
---
Form
Liquid
Metal Corrosion
---
Appearance
Liquid, Dark yellow
Relative Density
Not determined.
Flash Point
190 C
Solubility
---
Voc Content
---
Partition Coefficient
n-octanol/water: Not determined.
Cloud Point
---
Bulk Density
---
Dynamic Viscosity
Not determined.
Melting Point
0 C
Solidification Point
---
Freezing Point
0 C
Explosive Limits
---
Relative Evaporation Rate
---
Physical State Data
liquid
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for UNICUT MF-Spezial Frsen?

The signal word is no signal word.

What is the physical form of UNICUT MF-Spezial Frsen?

UNICUT MF-Spezial Frsen is a liquid appearing as liquid, dark yellow with dark yellow color. It has characteristic odor.

What is UNICUT MF-Spezial Frsen used for?

Metal working lubricant for minimum lubrication

What are the hazard statements for UNICUT MF-Spezial Frsen?

This substance has 1 hazard statement:

  • H412: Harmful to aquatic life with long lasting effects.

What is the melting point of UNICUT MF-Spezial Frsen?

The melting point is 0 C and the boiling point is 324 C.

Compliance Scan