NextSDS Logo
Safety Data Sheet EN

FennoStrength 505

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
FennoStrength 505

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Wet strength agent.

Uses advised against

Do not use for other purposes than the identified uses.

Manufacturers & Suppliers

K

Kemira Oyj

P.O. Box 33000101 HELSINKI FINLAND

+358108611

Emergency Contacts

Carechem 24 International (Europe)

+44 (0) 1235 239 670

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Aquatic Chronic Cat. 3

GHS Pictograms

Hazard Statements

H412 Harmful to aquatic life with long lasting effects.

Precautionary Statements

P273 Avoid release to the environment.
P501 Dispose of contents/ container to an approved waste disposal plant.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
N/A --- 19 - 21% Yes

For the full text of the H-Statements mentioned in this Section, see Section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If breathed in, move person into fresh air. Consult a physician after significant exposure.

Skin contact

Remove contaminated clothing. Wash off with soap and water. Seek medical advice if symptoms appear.

Eye contact

Rinse with plenty of water. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist.

Symptoms: eye irritation

Ingestion

Rinse mouth with water. Do not induce vomiting without medical advice. Never give anything by mouth to an unconscious person. Seek medical advice.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Water spray, Foam, Carbon dioxide (CO2), Dry chemical

Unsuitable media

High volume water jet

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Wear personal protective equipment. Avoid contact with skin, eyes and clothing.

Small spill

Soak up with inert absorbent material.

Large spill

Large spills should be collected mechanically (remove by pumping) for disposal.

Environmental

Try to prevent the material from entering drains or water courses. If the product contaminates rivers and lakes or drains inform respective authorities.

Cleanup methods

Large spills should be collected mechanically (remove by pumping) for disposal. Small spills: Soak up with inert absorbent material. Keep in suitable, closed containers for disposal.

Materials: inert absorbent material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with skin, eyes and clothing. Ensure adequate ventilation.

Storage

Keep container tightly closed in a dry and well-ventilated place. Store in cool place. Do not freeze.

Fire prevention

Normal measures for preventive fire protection.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Effective exhaust ventilation system

Hands

Gloves material: PVC, Break through time: > 480 min Gloves material: butyl-rubber, Break through time: > 480 min, Protective gloves complying with EN 374. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time.

Eyes

Safety glasses with side-shields conforming to EN166

Respiratory

not required under normal use

Skin/Body

Wear protective clothing (long-sleeved, long-legged).

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Solubility In Water
completely miscible
Molecular Weight
---
Solubility In Fat
---
Softening Point
---
Odor
Slight
Physical State
liquid (25 °C, 1 013 hPa), liquid
Density
---
Explosive Limits
---
Physical State Data
liquid
Boiling Point
> 100 °C
Flash Point
100 - 199 °C
Solidification Point
---
Freezing Point
---
Bulk Density
---
Colour Intensity
---
Upper Explosive Limit
Not applicable
Cloud Point
---
Vapor Density
---
Dynamic Viscosity
< 250 mPa.s (20 °C) (Brookfield)
Ph
2,5 - 4
Decomposition Temperature
---
Metal Corrosion
No data available
Odor Threshold
---
Relative Density
No data available
Voc Content
---
Flammability
No data available
Form
---
Solubility
---
Appearance
---
State Under Standard Conditions
---
Crystallisation Point
---
Properties Status
---
Partition Coefficient
No data available
Kinematic Viscosity
No data available
Evaporation Rate
No data available
Colour
yellow, clear
Melting Point
-1 °C
Auto Ignition Temperature
No data available
Vapor Pressure
< 25 hPa (20 °C)
Relative Evaporation Rate
---
Lower Explosive Limit
Not applicable
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage conditions.

Reactivity

Stable under normal conditions.

Hazardous reactions

No dangerous reaction known under conditions of normal use.

Avoid

Avoid extreme temperatures.

Incompatible

Strong alkalis Avoid contact with unalloyed steel or galvanized surfaces. Strong oxidizing agents Aluminium Copper Brass Iron

Decomposition

No hazardous decomposition products are known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for FennoStrength 505?

The signal word is no signal word.

What is the physical form of FennoStrength 505?

FennoStrength 505 is a liquid (25 °c, 1 013 hpa), liquid with yellow, clear color. It has slight odor.

What is FennoStrength 505 used for?

Wet strength agent.

What are the hazard statements for FennoStrength 505?

This substance has 1 hazard statement:

  • H412: Harmful to aquatic life with long lasting effects.

What is the melting point of FennoStrength 505?

The melting point is -1 °C and the boiling point is > 100 °C.

Compliance Scanner

Scan your compliance