Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- FennoStrength 505
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Wet strength agent.
Uses advised against
Do not use for other purposes than the identified uses.
Manufacturers & Suppliers
Kemira Oyj
manufacturer
P.O. Box 33000101 HELSINKI FINLAND
+358108611
Emergency Contacts
Carechem 24 International (Europe)
+44 (0) 1235 239 670
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Adipic acid-diethylenetriamine-epichlorohydrin polymer | --- | 19 - 21% | Yes |
For the full text of the H-Statements mentioned in this Section, see Section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
If breathed in, move person into fresh air. Consult a physician after significant exposure.
Remove contaminated clothing. Wash off with soap and water. Seek medical advice if symptoms appear.
Rinse with plenty of water. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist.
Rinse mouth with water. Do not induce vomiting without medical advice. Never give anything by mouth to an unconscious person. Seek medical advice.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Water spray, Foam, Carbon dioxide (CO2), Dry chemical
High volume water jet
Hazardous combustion products, Carbon dioxide (CO2), Nitrogen oxides (NOx)
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wear personal protective equipment. Avoid contact with skin, eyes and clothing.
Small spills: Soak up with inert absorbent material.
Large spills should be collected mechanically (remove by pumping) for disposal.
Try to prevent the material from entering drains or water courses. If the product contaminates rivers and lakes or drains inform respective authorities.
Keep in suitable, closed containers for disposal.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with skin, eyes and clothing. Ensure adequate ventilation.
Keep container tightly closed in a dry and well-ventilated place. Store in cool place. Do not freeze.
Normal measures for preventive fire protection.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Effective exhaust ventilation system
Gloves material: PVC, Break through time: > 480 min; Gloves material: butyl-rubber, Break through time: > 480 min, Protective gloves complying with EN 374. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time.
Safety glasses with side-shields conforming to EN166
not required under normal use
Wear protective clothing (long-sleeved, long-legged).
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage conditions.
Stable under normal conditions.
No dangerous reaction known under conditions of normal use.
Avoid extreme temperatures.
Strong alkalis, Avoid contact with unalloyed steel or galvanized surfaces., Strong oxidizing agents, Aluminium, Copper, Brass, Iron
No hazardous decomposition products are known.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The product should not be allowed to enter drains, water courses or the soil. Do not contaminate ponds, waterways or ditches with chemical or used container. Hazardous waste. Dispose of contents/container in accordance with local regulation.
Dispose of contents/container in accordance with local regulation.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
This product is to be considered as a preparation according to EU-legislation.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for FennoStrength 505?
The signal word is no signal word.
What is the physical form of FennoStrength 505?
FennoStrength 505 is a liquid appearing as yellow, clear with yellow, clear color. It has slight odor.
What is FennoStrength 505 used for?
Wet strength agent.
What are the hazard statements for FennoStrength 505?
This substance has 1 hazard statement:
- H412: Harmful to aquatic life with long lasting effects.
What is the melting point of FennoStrength 505?
The melting point is -1 °C and the boiling point is > 100 °C.