Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Honilo 981
- Product Code
- 450910-US03
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Metalworking fluid - neat.
Manufacturers & Suppliers
BP Lubricants USA Inc.
manufacturer
1500 Valley Road, Wayne, NJ 07470
+1-888-CASTROL
Emergency Contacts
Emergency Contact
+1-800-447-8735
CHEMTREC USA
+1-800-424-9300
CHEMTREC outside the US
+1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Highly refined base oil and additives
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Distillates (petroleum), straight-run middle | 64741-44-2 | 50 - 75% | No |
| Distillates (petroleum), hydrotreated light naphthenic | 64742-53-6 | 10 - 25% | No |
Occupational exposure limits, if available, are listed in Section 8.
Notes
Any concentration shown as a range is to protect confidentiality or is due to batch variation. There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health and hence require reporting in this section.
First Aid Measures
Emergency procedures for chemical exposure incidents
If inhaled, remove to fresh air. Get medical attention if symptoms occur.
Wash skin thoroughly with soap and water or use recognized skin cleanser. Remove contaminated clothing and shoes. Wash clothing before reuse. Clean shoes thoroughly before reuse. Get medical attention if symptoms occur.
In case of contact, immediately flush eyes with plenty of water for at least 15 minutes. Eyelids should be held away from the eyeball to ensure thorough rinsing. Check for and remove any contact lenses. Get medical attention.
Do not induce vomiting. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Get medical attention immediately.
Symptoms: Aspiration hazard if swallowed. Can enter lungs and cause damage.
Immediate Medical Attention
Get medical attention immediately.
Medical Treatment
Treatment should in general be symptomatic and directed to relieving any effects.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
In case of fire, use foam, dry chemical or carbon dioxide extinguisher or spray.
Do not use water jet.
Swarf fires - Neat metal working oils may fume, thermally decompose or ignite if they come into contact with red hot swarf. To minimise the generation of red hot swarf ensure that a sufficient flow of oil is correctly directed to the cutting edge of the tool to flood it throughout cutting operations. As an additional precaution swarf should be regularly cleared from the immediate area to prevent the risk of fire. In a fire or if heated, a pressure increase will occur and the container may burst.
No action shall be taken involving any personal risk or without suitable training. Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire.
Firefighter Protection
Fire-fighters should wear positive pressure self-contained breathing apparatus (SCBA) and full turnout gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Contact emergency personnel. No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Avoid breathing vapor or mist. Provide adequate ventilation. Put on appropriate personal protective equipment. Floors may be slippery; use care to avoid falling.
Stop leak if without risk. Move containers from spill area. Absorb with an inert material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.
Stop leak if without risk. Move containers from spill area. Approach release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations.
Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.
Absorb with an inert material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.
Materials: inert material, non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Put on appropriate personal protective equipment (see Section 8). Do not swallow. Aspiration hazard if swallowed. Can enter lungs and cause damage. Never siphon by mouth. Avoid contact with eyes, skin and clothing. Avoid breathing vapor or mist. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Empty containers retain product residue and can be hazardous. Do not reuse container. Concentrations of mist, fumes and vapors in enclosed spaces may result in the formation of explosive atmospheres. Excessive splashing, agitation or heating must be avoided. During metal working, solid particles from workpieces or tools will contaminate the fluid and may cause abrasions of the skin.
Store in accordance with local regulations. Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Store locked up. Keep container tightly closed and sealed until ready for use. Store and use only in equipment/containers designed for use with this product. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers. Use appropriate containment to avoid environmental contamination.
Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Wash thoroughly after handling. Remove contaminated clothing and protective equipment before entering eating areas.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide exhaust ventilation or other engineering controls to keep the relevant airborne concentrations below their respective occupational exposure limits.
Wear protective gloves if prolonged or repeated contact is likely. Wear chemical resistant gloves. Recommended: Nitrile gloves. The correct choice of protective gloves depends upon the chemicals being handled, the conditions of work and use, and the condition of the gloves (even the best chemically resistant glove will break down after repeated chemical exposures). Most gloves provide only a short time of protection before they must be discarded and replaced. Because specific work environments and material handling practices vary, safety procedures should be developed for each intended application. Gloves should therefore be chosen in consultation with the supplier/manufacturer and with a full assessment of the working conditions.
Safety glasses with side shields.
In case of insufficient ventilation, wear suitable respiratory equipment. For protection against metal working fluids, respiratory protection that is classified as "resistant to oil" (class R) or oil proof (class P) should be selected where appropriate. Depending on the level of airborne contaminants, an air-purifying, half-mask respirator (with HEPA filter) including disposable (P- or R-series) (for oil mists less than 50mg/m3), or any powered, air-purifying respirator equipped with hood or helmet and HEPA filter (for oil mists less than 125 mg/m3). Where organic vapours are a potential hazard during metalworking operations, a combination particulate and organic vapour filter may be necessary. The correct choice of respiratory protection depends upon the chemicals being handled, the conditions of work and use, and the condition of the respiratory equipment. Safety procedures should be developed for each intended application. Respiratory protection equipment should therefore be chosen in consultation with the supplier/manufacturer and with a full assessment of the working conditions.
Use of protective clothing is good industrial practice. Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Cotton or polyester/cotton overalls will only provide protection against light superficial contamination that will not soak through to the skin. Overalls should be laundered on a regular basis. When the risk of skin exposure is high (e.g. when cleaning up spillages or if there is a risk of splashing) then chemical resistant aprons and/or impervious chemical suits and boots will be required. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.
Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable.
No specific test data available for this product. Refer to Conditions to avoid and Incompatible materials for additional information.
Under normal conditions of storage and use, hazardous reactions will not occur. Under normal conditions of storage and use, hazardous polymerization will not occur.
Avoid all possible sources of ignition (spark or flame).
Reactive or incompatible with the following materials: oxidizing materials.
Under normal conditions of storage and use, hazardous decomposition products should not be produced.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Significant quantities of waste product residues should be processed in a suitable effluent treatment plant.
Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- Not regulated.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Honilo 981?
The signal word is danger.
What is the physical form of Honilo 981?
Honilo 981 is a liquid. with yellow. color. It has mild. odor.
What is the solubility of Honilo 981?
Not available.
What is Honilo 981 used for?
Metalworking fluid - neat.
What are the hazard statements for Honilo 981?
This substance has 1 hazard statement:
- H304: May be fatal if swallowed and enters airways.
What is the melting point of Honilo 981?
The melting point is Not available. and the boiling point is Not available..