NextSDS Logo
Safety Data Sheet FR

BICAR® FCC

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
BICAR® FCC
Chemical Name
Hydrogénocarbonate de sodium
Synonyms
Bicarbonate de sodium

Regulatory Identifiers

CAS Number
N/A
REACH No.
01-2119457606-32

Identified Uses

Additif alimentaire (E500ii), Traitement des eaux

Manufacturers & Suppliers

S

SOLVAY-CARBONATE-FRANCE S.A.S.

manufacturer

RUE GABRIEL PERI, F- 54110 DOMBASLE-SUR-MEURTHE

+33383185454

Emergency Contacts

CareChem 24

+44(0)1235 239 670

Centre Anti-poison

+3270245245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Bicarbonate de sodium EC: 205-633-8 144-55-8 99% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Amener la victime l'air libre.

Symptoms: Pas de dangers particuliers signaler.

Skin contact

Laver avec de l'eau et du savon.

Symptoms: Pas de dangers particuliers signaler. Exposition rpte ou prolonge: Le contact avec la poussire peut provoquer une irritation mcanique ou le dsschement de la peau.

Eye contact

Bien rincer avec beaucoup d'eau, y compris sous les paupires.

Symptoms: Le contact de la poussire avec les yeux peut provoquer une irritation mcanique.

Ingestion

Se rincer la bouche l'eau.

Symptoms: L'ingestion peut provoquer une irritation de l'appareil digestif, des nauses, des vomissements et des diarrhes.

Immediate Medical Attention

Si les troubles se prolongent (inhalation), consulter un mdecin. Si l'irritation oculaire persiste, consulter un mdecin spcialiste. Si les troubles se prolongent (ingestion), appeler immdiatement un mdecin ou un Centre AntiPoison.

Medical Treatment

Si les symptmes persistent ou si le moindre doute existe, il faut consulter un mdecin. Si l'irritation oculaire persiste, consulter un mdecin spcialiste.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Prvoir une ventilation adquate aux endroits o la poussire se forme. Appliquer les mesures techniques ncessaires pour respecter les valeurs limites d'exposition professionnelle.

Hands

Gants impermeables

Eyes

Lunettes de protection

Respiratory

Utiliser seulement un appareil respiratoire conforme aux rglements/ normes nationaux/internationaux. Respirateur avec un filtre poussire Type de Filtre recommand: P2

Skin/Body

Ne ncessite pas d'quipement de protection spcial.

Environmental

Eliminer l'eau de rinage en accord avec les rglementations locales et nationales.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
solid
Physical State Data
solid
State Under Standard Conditions
---
Appearance
cristallis, poudre
Colour
blanc
Colour Intensity
---
Form
---
Odor
inodore
Odor Threshold
---
Ph
8,4; 8,4 g/l, 25 (Eau); 8,6; 52 g/l
Melting Point
donne non disponible, Dcomposition thermique
Boiling Point
donne non disponible, Dcomposition thermique
Flash Point
non applicable, inorganique
Freezing Point
donne non disponible, Dcomposition thermique
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Pas de donnes
Vapor Pressure
donne non disponible, Dcomposition thermique
Vapor Density
non applicable
Relative Density
2,21 - 2,23, 20
Bulk Density
entre 0,5 - 1,3 kg/dm3
Density
2,21 kg/dm3
Flammability
Ce produit n'est pas inflammable. non applicable
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
non applicable
Decomposition Temperature
> 50
Solubility
insoluble, Alcool
Partition Coefficient
non applicable, inorganique
Solubility In Water
69 g/l (Eau), 0 93 g/l (Eau), 20 165 g/l (Eau), 60
Solubility In Fat
---
Molecular Weight
84,01 g/mol
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is BICAR® FCC known by?

BICAR® FCC is also known as: Bicarbonate de sodium

What is the hazard signal word for BICAR® FCC?

The signal word is no signal word.

What is the physical form of BICAR® FCC?

BICAR® FCC is a solid appearing as cristallis, poudre with blanc color. It has inodore odor.

What is the solubility of BICAR® FCC?

insoluble, Alcool

What is BICAR® FCC used for?

Additif alimentaire (E500ii), Traitement des eaux

What is the melting point of BICAR® FCC?

The melting point is donne non disponible, Dcomposition thermique and the boiling point is donne non disponible, Dcomposition thermique.