NextSDS Logo
LA

LASAL 2001

WARNING Gaz. SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
LASAL 2001
Product Form
Gaz
Product Code
EIGA089A
Chemical Name
Azote liquide réfrigéré
Synonyms
Nitrogen, Nitrogen gas, Gaseous Nitrogen, GAN

Regulatory Identifiers

CAS Number

Chemical Abstracts Service registry number - unique identifier for chemical substances

EC Number

European Community number - used for regulatory compliance in EU/EEA

Uses Information

Identified Uses
Industriel et professionnel. Faire une analyse des risques avant utilisation. Gaz de test ou d'étalonnage. Purge. Utilisation en laboratoire. Gas de protection pour procédés de soudage. Utiliser dans la fabrication de composants électroniques ou photovoltaïques. Gaz de purge, de dilution, d'inertage. Contacter le fournisseur pour plus d'information sur l'utilisation.

Overview

LASAL 2001 (CAS: 7727-37-9 ) commonly used industriel et professionnel. faire une analyse des risques avant utilisation. gaz de test ou d'étalonnage. purge. utilisation en laboratoire. gas de protection pour procédés de soudage. utiliser dans la fabrication de composants électroniques ou photovoltaïques. gaz de purge, de dilution, d'inertage. contacter le fournisseur pour plus d'information sur l'utilisation..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Attention)

Hazard Classifications

Gaz sous pression - Gaz comprims H280

GHS Hazard Pictograms & Safety Symbols

GHS04 GHS Hazard Pictogram: Compressed gas hazard - Pressurized gases that may explode if heated

GHS04

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H280: Contient un gaz sous pression; peut exploser sous l'effet de la chaleur.

Precautionary Statements

  • P403: Stocker dans un endroit bien ventil.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

AIR LIQUIDE BV

undefined

De Witbogt 1 5652 AG Eindhoven Pays-Bas-Nederland

NL

AIR LIQUIDE INDUSTRIE BV

undefined

Corkstraat 46 3047 AC Rotterdam Pays-Bas-Nederland

NL

AIR LIQUIDE BELGE S.A./N.V.

undefined

Quai des Vennes, 8 B-4020 Liège-Luik Belgique-België

BE

AIR LIQUIDE INDUSTRY BELGIUM

undefined

Bourgetlaan 44 1130 Bruxelles-Brussel Belgique-België

BE

L'AIR LIQUIDE LUXEMBOURG S.A.

undefined

ZONE P.E.D.-B.P.20 L-4801 RODANGE Luxemburg

LU

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

INDUSTRIAL MERCHANT

+31 (0)40 250 35 03

NL

INDUSTRIAL MERCHANT

+32 (0)4 349 89 89

BE

INDUSTRIAL MERCHANT

+352 50 62 63 1

LU

LARGE INDUSTRIES

+31 (0)10 2 622 077

NL

LARGE INDUSTRIES

+32 (0)2 431 73 54

BE

AIR LIQUIDE

+31 (0) 40 250 35 03

NL

AIR LIQUIDE

+32 (0)4 349 89 89

BE

AIR LIQUIDE

+352 50 62 63 1

LU

National Poisons Information Centre

030-2748888

NL

Centre antipoisons

070 245 245

BE

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Substance

General Composition

Azote : 100 %

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Azote liquide réfrigéré
EC: 231-783-9
7727-37-9 100% Hazardous

Additional Information

Voir le texte complet des Phrases-R la section 16. Voir la section 16 le texte complet des mentions-H.

Composition Notes

Ne contient pas d'autres composants ni impurets qui pourraient modifier la classification du produit. - 2: Date limite d'enregistrement non dpasse. - 3: Enregistrement non requis : Substance produite ou importe < 1 T / an.

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Dplacer la victime dans une zone non contamine, en s'quipant d'un appareil respiratoire autonome individuel (ARI). Maintenir la victime au chaud et au repos. Appeler un mdecin. Pratiquer la respiration artificielle si la victime ne respire plus.

Symptoms:

Peut causer l'asphyxie concentration leve. Les symptmes peuvent tre une perte de connaissance ou de motricit. La victime peut ne pas tre consciente de l'asphyxie.

Skin Contact

Pas d'effets nfastes attendus avec ce produit.

Symptoms:

Pas d'effets nfastes attendus avec ce produit.

Eye Contact

Pas d'effets nfastes attendus avec ce produit.

Symptoms:

Pas d'effets nfastes attendus avec ce produit.

Ingestion/Swallowing

L'ingestion n'est pas considre comme un mode d'exposition possible.

Symptoms:

L'ingestion n'est pas considre comme un mode d'exposition possible.

Immediate Medical Attention Required

Aucun(e).

Medical Treatment

Aucun(e).

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Physical State
Gaz.
Critical Property
Physical State Data
gas
State Under Standard Conditions
Not available
Appearance
Not available
Colour
Incolore.
Colour Intensity
Not available
Form
Not available
Odor
Non dtectable l'odeur.
Odor Threshold
La dtection des seuils par l'odeur est subjective et inapproprie pour alerter en cas de surexposition.
Ph
Non applicable.
Melting Point
-210
Critical Property
Boiling Point
-196
Critical Property
Flash Point
Non applicable aux gaz et aux mlanges de gaz.
Critical Property
Freezing Point
Not available
Softening Point
Not available
Solidification Point
Not available
Cloud Point
Not available
Crystallisation Point
Not available
Relative Evaporation Rate
Not available
Evaporation Rate
Non applicable aux gaz et aux mlanges de gaz.
Vapor Pressure
Non applicable.
Vapor Density
Not available
Relative Density
Not available
Bulk Density
Not available
Density
Not available
Flammability
Non-inflammable.
Upper Explosive Limit
Not available
Lower Explosive Limit
Not available
Explosive Limits
Not available
Auto Ignition Temperature
Non applicable.
Decomposition Temperature
Not available
Solubility
Not available
Partition Coefficient
Non applicable aux gaz non organiques.
Solubility In Water
20
Solubility In Fat
Not available
Molecular Weight
28
Voc Content
Not available
Metal Corrosion
Not available
Dynamic Viscosity
Non applicable.
Kinematic Viscosity
Not available
Properties Status
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Les équipements sous pression doivent être régulièrement contrôlés pour vérifier l'absence de fuites. Des détecteurs d'oxygène doivent être utilisés lorsque des gaz asphyxiants peuvent être relâchés. Maintenir une ventilation d'extraction appropriée localement et de l'ensemble. Penser au permis de travail, ex. pour la maintenance.

Hand Protection

Porter des gants de protection lors de la manutention des bouteilles de gaz. Norme EN 388-Gants de protection contre les risques mécaniques.

Eye Protection

Porter des lunettes de sécurité équipées de protections latérales. Norme EN 166 - Protection personnel des Yeux.

Respiratory Protection

Appareil de respiration autonome (SCBA) ou masque avec arrivée d'air à pression positive doivent être utilisés dans les atmosphères sous oxygènes. Norme EN 137 - Appareil autonome d' air comprimé en circuit ouvert avec un masque complet du visage.

Skin/Body Protection

Porter des chaussures de sécurité lors de la manutention de bouteilles. Norme EN ISO 20345: Equipements de Protection Individuelle - chaussures de sécurité.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

1066

Transport Hazard Class

2.2

Packing Group

Non applicable.

ADR Transport Precautions

éviter le transport dans des véhicules dont le compartiment du chargement n'est pas séparé par de la cabine de conduite. S'assurer que le conducteur du véhicule connaît les dangers potentiels du chargement ainsi que les mesures à prendre en cas d'accident ou autre situation d'urgence. Avant de transporter les récipients: - S'assurer que les récipients sont fermement arrimés. - S'assurer que le robinet de la bouteille est fermé et ne fuit pas. - S'assurer que le bouchon de protection de sortie du robinet (quand il existe) est correctement mis en place. - S'assurer que le dispositif de protection du robinet (quand il existe) est correctement mis en place. - S'assurer qu'il y a une ventilation appropriée.

IMDG Maritime Transport Precautions

éviter le transport dans des véhicules dont le compartiment du chargement n'est pas séparé par de la cabine de conduite. S'assurer que le conducteur du véhicule connaît les dangers potentiels du chargement ainsi que les mesures à prendre en cas d'accident ou autre situation d'urgence. Avant de transporter les récipients: - S'assurer que les récipients sont fermement arrimés. - S'assurer que le robinet de la bouteille est fermé et ne fuit pas. - S'assurer que le bouchon de protection de sortie du robinet (quand il existe) est correctement mis en place. - S'assurer que le dispositif de protection du robinet (quand il existe) est correctement mis en place. - S'assurer qu'il y a une ventilation appropriée.

IATA Air Transport Precautions

éviter le transport dans des véhicules dont le compartiment du chargement n'est pas séparé par de la cabine de conduite. S'assurer que le conducteur du véhicule connaît les dangers potentiels du chargement ainsi que les mesures à prendre en cas d'accident ou autre situation d'urgence. Avant de transporter les récipients: - S'assurer que les récipients sont fermement arrimés. - S'assurer que le robinet de la bouteille est fermé et ne fuit pas. - S'assurer que le bouchon de protection de sortie du robinet (quand il existe) est correctement mis en place. - S'assurer que le dispositif de protection du robinet (quand il existe) est correctement mis en place. - S'assurer qu'il y a une ventilation appropriée.

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What other names is LASAL 2001 known by?

LASAL 2001 is also known as: Nitrogen, Nitrogen gas, Gaseous Nitrogen, GAN

What is the hazard signal word for LASAL 2001?

The signal word for this substance is "warning".

What is the physical form of LASAL 2001?

LASAL 2001 is a gaz. with incolore. color. It has non dtectable l'odeur. odor.

What is LASAL 2001 used for?

Industriel et professionnel. Faire une analyse des risques avant utilisation. Gaz de test ou d'étalonnage. Purge. Utilisation en laboratoire. Gas de protection pour procédés de soudage. Utiliser dans la fabrication de composants électroniques ou photovoltaïques. Gaz de purge, de dilution, d'inertage. Contacter le fournisseur pour plus d'information sur l'utilisation.

What are the hazard statements for LASAL 2001?

This substance has 1 hazard statements: H280: Contient un gaz sous pression; peut exploser sous l'effet de la chaleur.

What is the melting point of LASAL 2001?

The melting point is -210 and the boiling point is -196.