NextSDS Logo
Na

Nachfüllgas

DANGER gaz liquéfié SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Nachfüllgas
Product Code
CFH No. 52103

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Carburant

Overview

Nachfüllgas commonly used carburant.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Aerosol Category 1

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H222: Aérosol extrêmement inflammable.
  • H229: Récipient sous pression: peut éclater sous l'effet de la chaleur.

Precautionary Statements

  • P102: Tenir hors de portée des enfants.
  • P210: Tenir à l'écart de la chaleur, des surfaces chaudes, des étincelles, des flammes nues et de toute autre source d'inflammation. Ne pas fumer.
  • P211: Ne pas vaporiser sur une flamme nue ou sur toute autre source d'ignition.
  • P251: Ne pas perforer, ni brûler, même après usage.
  • P410 + P412: Protéger du rayonnement solaire. Ne pas exposer à une température supérieure à 50 °C/122 °F.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

CFH Löt- und Gasgeräte GmbH company logo - Safety Data Sheet supplier organization

CFH Löt- und Gasgeräte GmbH

manufacturer

Bahnhofstraße 50 D-74254 Offenau

DE

+49 (0)7136 9594 0

+49 (0)7136 9594 44

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

GIZ-Nord

+49(0) 551 - 1 92 40

DE

24h

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
butane
EC: 203-448-7
106-97-8 80-90% Hazardous
propane
EC: 200-827-9
74-98-6 10-20% Hazardous
First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Transporter la personne à l'extérieur et la maintenir dans une position où elle peut confortablement respirer. Appeler un médecin en cas de malaise.

Skin Contact

Rincer abondamment avec de l'eau. Enlever les vêtements contaminés et les laver avant réutilisation.

Eye Contact

En cas de contact avec les yeux, rincer un moment avec de l'eau en gardant la paupière ouverte et consulter immédiatement un ophtamologiste.

Ingestion/Swallowing

EN CAS D'INGESTION: Appeler un médecin en cas de malaise.

Immediate Medical Attention Required

Consulter immédiatement un ophtamologiste en cas de contact avec les yeux. Appeler un médecin en cas de malaise après inhalation ou ingestion.

Medical Treatment

Traitement symptomatique.

Fire Safety

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

Suitable Extinguishing Media

Extincteur à sec, Dioxyde de carbone (CO2), mousse résistante à l'alcool

Unsuitable Extinguishing Media

Jet d'eau à grand débit

Specific Fire Hazards

Aérosol extrêmement inflammable. Récipient sous pression: peut éclater sous l’ effet de la chaleur. Non inflammable. Un échauffement provoque une élévation de la pression et génère un risque d 'éclatement.

Fire Fighting Instructions

En cas d'incendie: Utiliser un appareil respiratoire autonome. Utiliser un jet d'eau dans le périmètre de danger pour la protection des personnes et le refroidissement des récipients.

Firefighter Protection Equipment

Utiliser un appareil respiratoire autonome.

Spill Response

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

Emergency Procedures

Utiliser un équipement de protection personnel.

Environmental Precautions

Ne nécessite aucune mesure de prévention particulière pour la protection de l'environnement. Nettoyer soigneusement le sol et les objets souillés en se conformant aux réglementations relatives à l'environnement.

Cleanup Methods

Nettoyer soigneusement le sol et les objets souillés en se conformant aux réglementations relatives à l'environnement.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Physical State
gaz liquéfié
Critical Property
Physical State Data
gas
State Under Standard Conditions
Not available
Appearance
Not available
Colour
incolore
Colour Intensity
Not available
Form
Not available
Odor
Not available
Odor Threshold
Not available
Ph
non déterminé
Melting Point
non déterminé
Critical Property
Boiling Point
-44 °C
Critical Property
Flash Point
-97 °C
Critical Property
Freezing Point
Not available
Softening Point
Not available
Solidification Point
Not available
Cloud Point
Not available
Crystallisation Point
Not available
Relative Evaporation Rate
Not available
Evaporation Rate
non déterminé
Vapor Pressure
5000 hPa (à 20 °C)
Vapor Density
Not available
Relative Density
Not available
Bulk Density
Not available
Density
0,56 g/cm³
Critical Property
Flammability
solide: non applicable; gaz: non déterminé
Upper Explosive Limit
10,9 vol. %
Lower Explosive Limit
1,5 vol. %
Explosive Limits
Not available
Auto Ignition Temperature
365 °C
Decomposition Temperature
non déterminé
Solubility
non déterminé
Partition Coefficient
non déterminé
Solubility In Water
Not available
Solubility In Fat
Not available
Molecular Weight
Not available
Voc Content
Not available
Metal Corrosion
Not available
Dynamic Viscosity
Not available
Kinematic Viscosity
Not available
Properties Status
Not available
Handling & Storage

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

Handling Precautions

Ne pas perforer, ni brûler, même après usage.

Storage Conditions

Conserver les récipients bien fermés dans un endroit frais bien ventilé.

Ne pas fermer les récipients de manière étanche aux gaz.

Fire Prevention Measures

Ne pas vaporiser sur des flammes ou des objets incandescents. Protéger du rayonnement solaire. Ne pas exposer à une température supérieure à 50 °C/122 °F.

Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

S'assurer d'une ventilation suffisante et d'une aspiration ponctuelle au niveau des points critiques.

Hand Protection

Lors de la manipulation de substances chimiques, porter exclusivement des gants spécial chimie pourvus d'un marquage CE, y compris du numéro de contrôle à quatre chiffres. Le modèle des gants spécial chimie doit être choisi en fonction des concentrations et quantités des substances chimiques spécifiques au poste. Il est conseillé de demander au fabricant des précisions concernant la tenue aux agents chimiques des gants de protection susmentionnés pour des applications spécifiques.

Eye Protection

Porter un équipement de protection des yeux/du visage.

Respiratory Protection

Lorsque la ventilation du local est insuffisante porter un équipement de protection respiratoire.

Skin/Body Protection

Vêtements ignifuges. Porter des chaussures et des vêtements de travail antistatiques.

Section 10

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

Chemical Stability

Le produit est stable si stocké à des températures ambiantes normales.

Reactivity

Aérosol extrêmement inflammable. Récipient sous pression: peut éclater sous l’effet de la chaleur.

Hazardous Reactions

Des produits de réaction dangereux ne sont pas connus.

Conditions to Avoid

Tenir à l'écart de toute source de chaleur (p. ex. surfaces chaudes), des étincelles et des flammes directes. Les vapeurs peuvent former avec l'air un mélange explosif.

Incompatible Materials

Aucune information disponible.

Hazardous Decomposition Products

Des produits de décomposition dangereux ne sont pas connus.

Section 13

Waste Disposal & Treatment Methods

Waste disposal procedures, treatment methods, and regulatory compliance requirements

Product Disposal Recommendations

L'élimination doit se faire selon les prescriptions des autorités locales.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

UN 1950

Proper Shipping Name

AÉROSOLS

Transport Hazard Class

2

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Nachfüllgas?

The signal word for this substance is "danger".

What is the physical form of Nachfüllgas?

Nachfüllgas is a gaz liquéfié with incolore color.

What is the solubility of Nachfüllgas?

non déterminé

What is Nachfüllgas used for?

Carburant

What are the hazard statements for Nachfüllgas?

This substance has 2 hazard statements: H222: Aérosol extrêmement inflammable. H229: Récipient sous pression: peut éclater sous l'effet de la chaleur.

What is the melting point of Nachfüllgas?

The melting point is non déterminé and the boiling point is -44 °C.