NextSDS Logo
GR

GRF CLE Cleaner ANER PVC TI 1L*6 L58

DANGER Vloeibaar SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
GRF CLE Cleaner ANER PVC TI 1L*6 L58
Product Code
606-002-00-3

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Reinigingsmiddel

Overview

GRF CLE Cleaner ANER PVC TI 1L*6 L58 commonly used reinigingsmiddel.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Gevaar)

Hazard Classifications

Flam. Liq. Category 2 H225
Eye Irrit. Category 2 H319
STOT SE Category 3 H336

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H225: Licht ontvlambare vloeistof en damp.
  • H319: Veroorzaakt ernstige oogirritatie.
  • H336: Kan slaperigheid of duizeligheid veroorzaken.

Precautionary Statements

  • P101: Bij het inwinnen van medisch advies, de verpakking of het etiket ter beschikking houden.
  • P102: Buiten het bereik van kinderen houden.
  • P210: Verwijderd houden van warmte, hete oppervlakken, vonken, open vuur en andere ontstekingsbronnen. Niet roken.
  • P261: Inademing van damp vermijden.
  • P403+P233: Op een goed geventileerde plaats bewaren. In goed gesloten verpakking bewaren.
  • P501: De inhoud/verpakking afvoeren overeenkomstig de nationale voorschriften.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Bison International

manufacturer

πŸ“

Dr.A.F.Philipsstraat 9 NL-4462 EW Goes PO Box 160 NL-4460 AD Goes

🌍

NL

πŸ“ž

+31 88 3235700

πŸ“ 

+31 88 3235800

Bison International

manufacturer

πŸ“

Excelsiorlaan 27, B 3 B-1930 Zaventem

🌍

BE

πŸ“ž

+32 3 710 92 92

πŸ“ 

+32 3 710 92 90

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Antigifcentrum

πŸ“ž

070 245245

🌍

BE

Emergency Contact

πŸ“ž

8002 - 5500

🌍

LU

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
butanon
EC: 201-159-0
78-93-3 Not specified βœ“ Non-hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Frisse lucht toedienen; bij klachten arts ontbieden. Geen speciale maatregelen noodzakelijk.

πŸ‘οΈ Eye Contact

De ogen gedurende verscheidene minuten onder stromend water afspoelen terwijl de oogspleet geopend blijft. Bij aanhoudende klachten een dokter raadplegen.

🚨 Immediate Medical Attention Required

Geen verdere relevante informatie verkrijgbaar.

Medical Treatment

Geen verdere relevante informatie verkrijgbaar.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

πŸ§ͺ Physical State
Vloeibaar
Critical Property
πŸ“Š Physical State Data
liquid
πŸ“Š State Under Standard Conditions
Not available
πŸ‘οΈ Appearance
Not available
🎨 Colour
Kleurloos
πŸ“Š Colour Intensity
Not available
πŸ“Š Form
Vloeibaar
πŸ‘ƒ Odor
Ketonachtig
πŸ“Š Odor Threshold
Niet bepaald.
πŸ§ͺ Ph
Niet bepaald.
🧊 Melting Point
-86,3 C
Critical Property
πŸ’¨ Boiling Point
79-80,5 C
Critical Property
πŸ”₯ Flash Point
-9 C
Critical Property
πŸ“Š Freezing Point
-86,3 C
πŸ“Š Softening Point
Not available
πŸ“Š Solidification Point
Not available
πŸ“Š Cloud Point
Not available
πŸ“Š Crystallisation Point
Not available
πŸ“Š Relative Evaporation Rate
Not available
πŸ’¨ Evaporation Rate
Niet bepaald.
πŸ’¨ Vapor Pressure
105 hPa
πŸ“Š Vapor Density
Niet bepaald.
πŸ“Š Relative Density
Niet bepaald.
πŸ“Š Bulk Density
Not available
βš–οΈ Density
0,804-0,807 g/cm
Critical Property
πŸ”₯ Flammability
Licht ontvlambaar. Licht ontvlambare vloeistof en damp.
πŸ“Š Upper Explosive Limit
11,5 Vol %
πŸ“Š Lower Explosive Limit
1,8 Vol %
πŸ“Š Explosive Limits
Not available
πŸ“Š Auto Ignition Temperature
514 C
πŸ“Š Decomposition Temperature
Niet bepaald.
πŸ’§ Solubility
Not available
πŸ“Š Partition Coefficient
Niet bepaald.
πŸ“Š Solubility In Water
290 g/l
πŸ“Š Solubility In Fat
Not available
πŸ“Š Molecular Weight
72,11 g/mol
πŸ“Š Voc Content
Not available
πŸ“Š Metal Corrosion
Niet van toepassing
πŸ“Š Dynamic Viscosity
0,4 mPas
πŸ“Š Kinematic Viscosity
Niet bepaald.
πŸ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🧀 Hand Protection

Handschoenen / bestand tegen oplosmiddelen. Het handschoenmateriaal moet ondoorlatend en bestand zijn tegen het product / de stof / de bereiding. Kies handschoenmateriaal rekening houdend met de penetratietijden, de permeatiegraden en de degradatie. Aanbevolen materiaaldikte: > 0,12 mm (Butylrubber, Nitrilrubber). Aanbevolen materiaaldikte: > 0,7 mm. Voor het mengsel van de hieronder vermelde chemicaliΓ«n moet de penetratietijd minstens 10 minuten bedragen (permeatie volgens EN 374 Deel 3: Level 1). Voor het mengsel van de hieronder vermelde chemicaliΓ«n moet de penetratietijd minstens 120 minuten bedragen (permeatie volgens EN 374 Deel 3: Level 4).

πŸ‘οΈ Eye Protection

Nauw aansluitende veiligheidsbril. Bij het omgieten is het gebruik van een veiligheidsbril aan te bevelen.

😷 Respiratory Protection

Bij onvoldoende ventilatie ademhalingsbescherming. Aanbevolen filter voor kortstondig gebruik: Filter A

🦺 Skin/Body Protection

Tegen oplosmiddelen bestande beschermingskleding

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

🏷️ UN Number

UN1193

πŸ“¦ Proper Shipping Name

ETHYL METHYL KETONE (METHYL ETHYL KETONE)

⚠️ Transport Hazard Class

3

πŸ“‹ Packing Group

II

πŸš› ADR Transport Precautions

Waarschuwing: Brandbare vloeistoffen

🚒 IMDG Maritime Transport Precautions

Waarschuwing: Brandbare vloeistoffen

✈️ IATA Air Transport Precautions

Waarschuwing: Brandbare vloeistoffen

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for GRF CLE Cleaner ANER PVC TI 1L*6 L58?

The signal word for this substance is "danger".

What is the physical form of GRF CLE Cleaner ANER PVC TI 1L*6 L58?

GRF CLE Cleaner ANER PVC TI 1L*6 L58 is a vloeibaar with kleurloos color. It has ketonachtig odor.

What is GRF CLE Cleaner ANER PVC TI 1L*6 L58 used for?

Reinigingsmiddel

What are the hazard statements for GRF CLE Cleaner ANER PVC TI 1L*6 L58?

This substance has 3 hazard statements: H225: Licht ontvlambare vloeistof en damp. H319: Veroorzaakt ernstige oogirritatie. H336: Kan slaperigheid of duizeligheid veroorzaken.

What is the melting point of GRF CLE Cleaner ANER PVC TI 1L*6 L58?

The melting point is -86,3 C and the boiling point is 79-80,5 C.