NextSDS Logo
Ac

Aceton ROTISOLV® ≥99,9 %, UV/IR-Grade

DANGER vloeibaar SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Aceton ROTISOLV® ≥99,9 %, UV/IR-Grade
Product Code
T906
Chemical Name
ACETON
Synonyms
Niet beschikbaar.

Regulatory Identifiers

CAS Number

Chemical Abstracts Service registry number - unique identifier for chemical substances

EC Number

European Community number - used for regulatory compliance in EU/EEA

REACH Registration Number
01-2119471330-49

Registration, Evaluation, Authorisation and Restriction of Chemicals - EU regulation compliance

Uses Information

Identified Uses
Laboratoriumchemicaliën Analytische en laboratoriumtoepassingen
Uses Advised Against
Niet te gebruiken voor producten die in contact met voedsel komen. Niet te gebruiken voor privédoeleinden (huishouden).

Overview

Aceton ROTISOLV® ≥99,9 %, UV/IR-Grade (CAS: 67-64-1 ) commonly used laboratoriumchemicaliën analytische en laboratoriumtoepassingen.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Gevaar)

Hazard Classifications

Flam. Liq. Category 2 H225
Eye Irrit. Category 2 H319
STOT SE Category 3 H336

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H225: Licht ontvlambare vloeistof en damp
  • H319: Veroorzaakt ernstige oogirritatie
  • H336: Kan slaperigheid of duizeligheid veroorzaken

Precautionary Statements

  • P210: Verwijderd houden van warmte, vonken, open vuur, hete oppervlakken. Niet roken
  • P305 + P351 + P338: BIJ CONTACT MET DE OGEN: voorzichtig afspoelen met water gedurende een aantal minuten; contactlenzen verwijderen, indien mogelijk; blijven spoelen
  • P403 + P233: Op een goed geventileerde plaats bewaren. In goed gesloten verpakking bewaren
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Carl Roth GmbH + Co KG company logo - Safety Data Sheet supplier organization

Carl Roth GmbH + Co KG

manufacturer

Schoemperlenstr. 3-5 D-76185 Karlsruhe Duitsland

DE

+49 (0) 721 - 56 06 0

+49 (0) 721 - 56 06 149

CARL ROTH GmbH + Co. KG Nederland company logo - Safety Data Sheet supplier organization

CARL ROTH GmbH + Co. KG Nederland

importer

NL

+31 180 516 704

+49 721 5606-260

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Nationaal Vergiftigingen Informatie Centrum

030 - 274 8888

NL

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Aceton
EC: 200-662-2
67-64-1 Not specified Non-hazardous
First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Voor verse lucht zorgen. Bij twijfel of bij aanhoudende symptomen een arts raadplegen.

Symptoms:

Hoofdpijn, Duizeligheid, Slaperigheid, Narcotische werking

Skin Contact

Huid met water afspoelen/afdouchen.

Symptoms:

Irritatie

Eye Contact

Minstens 10 minuten met schoon, vloeiend water spoelen terwijl de oogleden worden opengehouden. Bij oogirritatie een oogarts consulteren.

Symptoms:

Oogirritatie

Ingestion/Swallowing

De mond spoelen. Bij onwel voelen een arts raadplegen.

Symptoms:

Misselijkheid, Braken, Maagdarmklachten, onwel voelen

Fire Safety

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

Suitable Extinguishing Media

brandbestrijdingsmaatregelen op de omgeving afstemmen sproeiwater, alcohol bestendig schuim, droog bluspoeder, BC-poeder, kooldioxide (CO₂)

Unsuitable Extinguishing Media

volle waterstraal

Specific Fire Hazards

Brandbaar. Bij ontoereikende ventilatie en/of bij gebruik ontstaan van explosieve/licht ontvlambare damp-luchtmengsels mogelijk. Dampen van oplosmiddelen zijn zwaarder dan lucht en kunnen zich over de vloer verspreiden. Op plaatsen waar geen ventilatie mogelijk is zoals onbeluchte ondergrondse plaatsen bijv. putten, kanalen en schachten is met de aanwezigheid van brandbare stoffen rekening te houden. Dampen zijn zwaarder dan lucht, verspreiden zich via de grond en vormen samen met lucht een explosief mengsel. Dampen kunnen samen met lucht een explosief mengsel vormen.

Fire Fighting Instructions

In geval van brand en/of explosie inademen van rook vermijden. Met normale voorzorgen vanaf een redelijke afstand blussen.

Firefighter Protection Equipment

Draag onafhankelijke ademhalingsapparatuur.

Spill Response

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

Emergency Procedures

Contact met huid, ogen en kleding vermijden. Damp/spuitnevel niet inademen. Voorkoming van ontstekingsbronnen.

Environmental Precautions

Vermijden dat het product in afvoerkanalen, oppervlaktewater of grondwater terechtkomt. Explosiegevaar.

Cleanup Methods

Met vloeistofbindende stoffen opnemen.

Cleanup Materials:

zand, diatomeeënaarde, zuurbinder, universeel binder

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Relative Evaporation Rate
Not available
Metal Corrosion
Not available
Vapor Pressure
240 hPa bij 20 °C
Decomposition Temperature
niet relevant
Solubility
Not available
State Under Standard Conditions
Not available
Explosive Limits
Not available
Cloud Point
Not available
Solidification Point
Not available
Flash Point
-17 °C (ECHA)
Critical Property
Appearance
Not available
Dynamic Viscosity
Not available
Physical State Data
liquid
Crystallisation Point
Not available
Freezing Point
Not available
Relative Density
Not available
Bulk Density
Not available
Auto Ignition Temperature
465 °C (ECHA)
Solubility In Fat
Not available
Boiling Point
56,05 °C (ECHA)
Critical Property
Vapor Density
Not available
Colour Intensity
Not available
Voc Content
Not available
Odor Threshold
Not available
Properties Status
Not available
Melting Point
-94,8 °C (ECHA)
Critical Property
Partition Coefficient
Verdelingscoëfficiënt n-octanol/water (logwaarde): -0,23 (ECHA)
Upper Explosive Limit
12,8 vol%
Kinematic Viscosity
0,4051mm²/s
Density
0,79g/cm³bij 20 °C
Critical Property
Colour
kleurloos
Flammability
ontvlambare vloeistof overeenkomstig GHS-criteria
Molecular Weight
Not available
Softening Point
Not available
Solubility In Water
in elke verhouding mengbaar
Form
Not available
Lower Explosive Limit
2,6 vol%
Ph
5 – 6 (in aqueous solution: 395g/l, 20 °C)
Odor
matig zoet - fruitig
Evaporation Rate
Not available
Physical State
vloeibaar
Critical Property
Handling & Storage

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

Handling Precautions

Maatregelen voor voldoende ventilatie.

Wanneer niet in gebruik, in goed gesloten verpakkingen bewaren.

Storage Conditions

Op een goed geventileerde plaats bewaren.

In goed gesloten verpakking bewaren.

General Hygiene Measures

Voor werkpauze en werkeinde handen wassen. Verwijderd houden van eet- en drinkwaren en van diervoeder. Niet roken tijdens gebruik.

Fire Prevention Measures

Verwijderd houden van ontstekingsbronnen - Niet roken.

Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Hand Protection

Draag geschikte handschoenen. Geschikt zijn volgens EN 374 beproefde handschoenen tegen chemicaliën. Er wordt aangeraden om in geval van speciale applicaties de chemische bestendigheid van de boven genoemde veiligheidshandschoenen samen met de leverancier van de handschoenen na te gaan. De tijden zijn geschatte waarden van metingen bij 22 ° C en permanent contact. Verhoogde temperaturen als gevolg van verhitte stoffen, lichaamswarmte enz. En een vermindering van de effectieve laagdikte door rekken kan leiden tot een aanzienlijke verkorting van de doorbraaktijd. Neem in geval van twijfel contact op met de fabrikant. Bij een ongeveer 1,5 maal grotere / kleinere laagdikte wordt de respectieve doorbraaktijd verdubbeld / gehalveerd. De gegevens zijn alleen van toepassing op de zuivere stof. Bij overdracht op mengsels van stoffen mogen ze alleen als richtlijn worden beschouwd. Soort materiaal: Butylrubber. Materiaaldikte: 0,7mm. Doorbraaktijd van het handschoenmateriaal: >480 minuten (permeatieniveau: 6).

Eye Protection

Veiligheidsbril met zijbescherming dragen.

Respiratory Protection

Adembescherming is noodzakelijk bij: Aërosol- of nevelvorming. Type: AX (gasfilters en combinatiefilters tegen organische verbindingen met laag kookpunt , kleurcode: bruin).

Skin/Body Protection

Beschermingskleding tegen vlammen.

Environmental Exposure Controls

Vermijden dat het product in afvoerkanalen, oppervlaktewater of grondwater terechtkomt.

Section 10

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

Chemical Stability

Het materiaal is stabiel onder normale atmosferische omstandigheden en verwachte temperatuur en druk bij opslag en hantering.

Reactivity

Het is een reactieve stof. Gevaar van ontsteking. Dampen kunnen samen met lucht een explosief mengsel vormen. Bij verhitting Gevaar van ontsteking.

Hazardous Reactions

Gevaar van ontsteking: sterk oxiderend, Reductiemiddelen, Salpeterzuur, Chroom(VI)-oxide, Exotherme reactie met: Alkalimetalen, Alkalihydroxide (bijtende alkali), Broom, Gehalogeneerde koolwaterstoffen, Explosierisico: Chloroform, Waterstofperoxide

Conditions to Avoid

Verwijderd houden van warmte, hete oppervlakken, vonken, open vuur en andere ontstekingsbronnen. Niet roken.

Incompatible Materials

Producten van rubber, verschillende kunststoffen

Hazardous Decomposition Products

Gevaarlijke verbrandingsproducten: zie rubriek 5.

Section 13

Waste Disposal & Treatment Methods

Waste disposal procedures, treatment methods, and regulatory compliance requirements

Waste Treatment Methods

Afval wordt gescheiden in de categorieën die afzonderlijk kunnen worden behandeld door de lokale of nationale afvalbeheerdiensten.

Product Disposal Recommendations

Deze stof als gevaarlijk afval afvoeren. Inhoud afvoeren overeenkomstig de plaatselijke/regionale/nationale/internationale voorschriften.

Waste Classification Codes

De toekenning van de afvalsleutelnummers/afvalmarkeringen dient conform AVV branche- en processpecifiek plaats te vinden. national code
Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

1090

Proper Shipping Name

ACETON

Transport Hazard Class

3

Packing Group

II

ADR Transport Precautions

Aan de bepalingen voor gevaarlijke goederen (ADR) moet ook in het bedrijf worden voldaan.

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What other names is Aceton ROTISOLV® ≥99,9 %, UV/IR-Grade known by?

Aceton ROTISOLV® ≥99,9 %, UV/IR-Grade is also known as: Niet beschikbaar.

What is the hazard signal word for Aceton ROTISOLV® ≥99,9 %, UV/IR-Grade?

The signal word for this substance is "danger".

What is the physical form of Aceton ROTISOLV® ≥99,9 %, UV/IR-Grade?

Aceton ROTISOLV® ≥99,9 %, UV/IR-Grade is a vloeibaar with kleurloos color. It has matig zoet - fruitig odor.

What is Aceton ROTISOLV® ≥99,9 %, UV/IR-Grade used for?

Laboratoriumchemicaliën Analytische en laboratoriumtoepassingen

What are the hazard statements for Aceton ROTISOLV® ≥99,9 %, UV/IR-Grade?

This substance has 3 hazard statements: H225: Licht ontvlambare vloeistof en damp H319: Veroorzaakt ernstige oogirritatie H336: Kan slaperigheid of duizeligheid veroorzaken

What is the melting point of Aceton ROTISOLV® ≥99,9 %, UV/IR-Grade?

The melting point is -94,8 °C (ECHA) and the boiling point is 56,05 °C (ECHA).