Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- IG-541/Inergen
- Product Code
- 73130002
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
No information available
Uses advised against
No information available
Manufacturers & Suppliers
Tyco Fire Suppression & Building Products
undefined
1 Kopersteden TJ Enschede, Netherlands
3153-428-4444
Emergency Contacts
CHEMTREC
001-800-424-9300
CHEMTREC
001-703-527-3887
National Poisons Information Centre (NPIC)
+353-1809 2566
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS04
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Carbon Dioxide EC: 204-696-9 | 124-38-9 | 10% | Yes |
Notes
Full text of H- and EUH-phrases: see section 16
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. If breathing is difficult, give oxygen. (Get medical attention immediately if symptoms occur.)
Wash skin with soap and water. Get medical attention if irritation develops and persists.
Symptoms: Irritation
Rinse thoroughly with plenty of water for at least 15 minutes, lifting lower and upper eyelids. Consult a doctor.
Rinse mouth. Do not induce vomiting without medical advice. If swallowed, call a poison control centre or physician immediately.
Immediate Medical Attention
Call 911 or emergency medical service. Get medical attention immediately if symptoms occur (inhalation). Get medical attention if irritation develops and persists (skin contact). Consult a doctor (eye contact). If swallowed, call a poison control centre or physician immediately (ingestion).
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
None known.
Firefighter Protection
Wear self-contained breathing apparatus and protective suit. Use personal protective equipment as required.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Ensure adequate ventilation, especially in confined areas. Use personal protection recommended in Section 8.
Prevent further leakage or spillage if safe to do so. Prevent entry into waterways, sewers, basements or confined areas. See Section 12 for additional Ecological Information.
Pick up and transfer to properly labelled containers.
Related Substances
Similar chemicals with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with skin and eyes. Handle in accordance with good industrial hygiene and safety practice.
Keep containers tightly closed in a dry, cool and well-ventilated place.
Do not eat, drink or smoke when using this product. Handle in accordance with good industrial hygiene and safety practice.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation, especially in confined areas.
Wear protective natural rubber, nitrile rubber, Neoprene™ or PVC gloves. Gloves must conform to standard EN 374.
Avoid contact with eyes. Tight sealing safety goggles.
In case of insufficient ventilation, wear suitable respiratory equipment. Wear a respirator conforming to EN 140 with Type A filter or better.
Wear impervious protective clothing, including boots, gloves, lab coat, apron or coveralls, as appropriate, to prevent skin contact.
No information available.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage conditions.
No data available.
None under normal processing. Hazardous polymerisation does not occur.
Extremes of temperature and direct sunlight.
Strong oxidising agents. Strong acids. Strong bases.
Carbon oxides. Nitrogen oxides (NOx).
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Disposal should be in accordance with applicable regional, national and local laws and regulations.
Disposal should be in accordance with applicable regional, national and local laws and regulations.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1956
- Shipping Name
- Compressed gas, n.o.s.
- Transport Class
- 2.2
- Packing Group
- NOT REGULATED
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Take note of Directive 98/24/EC on the protection of the health and safety of workers from the risks related to chemical agents at work
This product does not contain substances subject to authorisation (Regulation (EC) No. 1907/2006 (REACH), Annex XIV)
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for IG-541/Inergen?
The signal word is warning.
What is the physical form of IG-541/Inergen?
IG-541/Inergen is a compressed gas with colourless color.
What is the solubility of IG-541/Inergen?
No data available
What is IG-541/Inergen used for?
No information available
What are the hazard statements for IG-541/Inergen?
This substance has 1 hazard statement:
- H280: Contains gas under pressure; may explode if heated
What is the melting point of IG-541/Inergen?
The melting point is No data available and the boiling point is -196 °C.