Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
ROSEMARY & OLIVE OIL K178183000 E_1003526/08
Product Code
K178183000 ROO

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Perfume composition, flavour or aromatical ingredient, for an industrial usage, that can be used in end-user product.

Manufacturers & Suppliers

V

V. MANE Fils

global supplier

620, Route de GRASSE- 06620 LE-BAR-SUR-LOUP- FRANCE

(33).4.93.09.70.00

Emergency Contacts

NCEC (regional)

+44 1865 407333

Official advisory body

070245245

NCEC (Middle East/Africa)

+44 1235 239671

NCEC (Americas)

+1 215 207 0061

NCEC (Asia)

+65 3158 1074

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Eye Irrit. Cat. 2 H319

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H319 Causes serious eye irritation.

Precautionary Statements

P280 Wear protective gloves/protective clothing/eye protection/face protection.
P305+P351+P338 IF IN EYES: Rinse with water for several minutes. Remove contact lenses, if present.
P337+P313 If eye irritation persists: Get medical advice

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Chemical Name CAS Number Concentration Hazardous
S-LACTIC ACID, CALCIUM L-LACTATE --- 1 - 5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and keep at rest in a position comfortable for breathing.

Skin contact

Remove/take off immediately all contaminated clothing. Rinse skin with water/shower.

Eye contact

Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

Ingestion

Rinse mouth. Do NOT induce vomiting.

Immediate Medical Attention

Get medical attention if symptoms persist.

Related Substances

Similar chemicals with comparable safety profiles

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use in a well-ventilated area. In the event that ventilation is not sufficient to prevent inhalation of substances or reduce airborne concentrations below an established occupational exposure limit, use an adequate respiratory apparatus to supplement the engineering measures already in place. These recommendations must be adapted according to the hazard analysis specific to the workplace.

Hands

Use chemical resistant gloves in accordance with Standard EN 374 for protective gloves against chemicals. When prolonged or frequently repeated contact may occur, a glove with a protection class of 4 or higher (breakthrough time greater than 120 minutes according to Standard EN 374) is recommended. When only brief contact is expected, a glove with a protection class of 1 or higher (breakthrough time greater than 10 minutes according to Standard EN 374) is recommended. Thickness > or = 0.2 mm. Please observe the instructions regarding permeability and breakthrough time which are provided by the glove supplier. Permeation time must exceed contact time. Choose the type of gloves according to the chemical properties of the products being handled. Change gloves according to the manufacturer's recommendations or if they are damaged. Wear protective clothing covering the arms and legs. Use an apron or full suit if exposure is expected. These recommendations must be adapted according to the hazard analysis specific to the workplace.

Eyes

Use safety glasses or a face shield according to Standard EN 166 and according to the hazard analysis specific to the workplace (chemical to be handled, protocol for use, frequency of use, quantity used, etc.).

Respiratory

Use in a well-ventilated area. In the event that ventilation is not sufficient to prevent inhalation of substances or reduce airborne concentrations below an established occupational exposure limit, use an adequate respiratory apparatus to supplement the engineering measures already in place. These recommendations must be adapted according to the hazard analysis specific to the workplace.

Skin/Body

Wear protective clothing covering the arms and legs. Use an apron or full suit if exposure is expected. These recommendations must be adapted according to the hazard analysis specific to the workplace.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
POWDER
Physical State Data
solid
State Under Standard Conditions
---
Appearance
---
Colour
OFF WHITE
Colour Intensity
---
Form
---
Odor
Characteristic
Odor Threshold
---
Ph
No data available.
Melting Point
No data available.
Boiling Point
No data available.
Flash Point
No data available.
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available.
Vapor Pressure
No data available.
Vapor Density
No data available.
Relative Density
No data available.
Bulk Density
---
Density
---
Flammability
No data available.
Upper Explosive Limit
No data available.
Lower Explosive Limit
No data available.
Explosive Limits
---
Auto Ignition Temperature
No data available.
Decomposition Temperature
No data available.
Solubility
No data available.
Partition Coefficient
No data available.
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for ROSEMARY & OLIVE OIL K178183000 E_1003526/08?

The signal word is warning.

What is the physical form of ROSEMARY & OLIVE OIL K178183000 E_1003526/08?

ROSEMARY & OLIVE OIL K178183000 E_1003526/08 is a powder with off white color. It has characteristic odor.

What is the solubility of ROSEMARY & OLIVE OIL K178183000 E_1003526/08?

No data available.

What is ROSEMARY & OLIVE OIL K178183000 E_1003526/08 used for?

Perfume composition, flavour or aromatical ingredient, for an industrial usage, that can be used in end-user product.

What are the hazard statements for ROSEMARY & OLIVE OIL K178183000 E_1003526/08?

This substance has 1 hazard statement:

  • H319: Causes serious eye irritation.

What is the melting point of ROSEMARY & OLIVE OIL K178183000 E_1003526/08?

The melting point is No data available. and the boiling point is No data available..